EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ultrasound location of ground-glass opacity during thoracoscopic surgery

Gaetana Messina iD, Mary Bove, Giovanni Natale, Antonio Noro, Mario Martone, Giorgia Opromolla, Vincenzo Di Filippo, Beatrice Leonardi, Morena Fasano, Rita Polito, Alfonso Fiorelli iD, Mario Santini iD und 1 weitere

Interactive CardioVascular and Thoracic Surgery · 08.11.2022 · 35 (6)

DOI: 10.1093/icvts/ivac234 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Interactive CardioVascular and Thoracic Surgery, online erschienen am 05.09.2022. Verfasst von Gaetana Messina und 12 weiteren Autor:innen. Beteiligte Einrichtung: Thoracic Surgery Unit, Università degli Studi della Campania "Luigi Vanvitelli", Napoli, Campania, Italy. Hauptthemen laut MEDLINE: Lung Neoplasms, Adenocarcinoma. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Campania L. Vanvitelli.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES Application of video-assisted thoracoscopy brought lung surgery into the minimally invasive era; the lack of tactile feedback using VATS, remains a disadvantage because surgeons are unable to locate lesions with a finger or device. This study aimed to investigate the effectiveness, the applicability and the utility of intraoperative ultrasound (IU), for the localization of small ground-glass opacity (GGO) lesions in the parenchyma, as a guide in finding their margins in a deflated lung. MATERIALS AND METHODS We included 15 consecutive patients undergoing diagnostic resection of GGOs via VATS in the Thoracic Surgery Unit of the University of ‘Luigi Vanvitelli’ of Naples from November 2019 to December 2021. They were under general anaesthesia, when the lung had been collapsed, the probe was placed in the region where the target lesion was thought to reside on the basis of low-dose computed tomography scanning. GGO could be identified their sizes, echo levels and posterior echo was recorded by IU when the lung was completely deflated. RESULTS We conducted a retrospective single-centre study. All GGOs were identified by IU. The mean size and depth were 14.1 ± 0.5 and 4.8 ± 0.3 mm, respectively. Six (40%) lesions had hyperechoic patterns, 9 (60%) had mixed echogenicity where the hyperechoic patterns were irregularly mixed with hypoechoic patterns. The final diagnoses included 2 (15%) atypical adenomatous hyperplasia; 2 (15%) adenocarcinomas in situ; 3 (23%) minimally invasive adenocarcinomas and 6 (46%) invasive adenocarcinomas. CONCLUSIONS The results of our study showed that IU could safely and effectively detect GGOs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lung NeoplasmsAdenocarcinomaHumansRetrospective StudiesThoracic Surgery, Video-AssistedUltrasonography

Stichwörter der Autor:innen

Ground-glass opacity patternThoracic surgeryUltrasound

Autor:innen und Institutionen

  • Thoracic Surgery Unit, Università degli Studi della Campania "Luigi Vanvitelli", Napoli, Campania, Italy.
  • Oncology, Department of Precision Medicine, Università della Campania "L. Vanvitelli", Napoli, Campania, Italy.
  • Nutrition Science, University of Foggia, Foggia, Italy.

ORCID-Profile: Gaetana Messina, Alfonso Fiorelli, Mario Santini

Förderung

  • University of Campania L. Vanvitelli

Zitieren

APA

Messina, G., Bove, M., Natale, G., Noro, A., Martone, M., Opromolla, G., Di Filippo, V., Leonardi, B., Fasano, M., Polito, R., Fiorelli, A., Santini, M., & Vicidomini, G. (2022). Ultrasound location of ground-glass opacity during thoracoscopic surgery. Interactive CardioVascular and Thoracic Surgery, 35(6). https://doi.org/10.1093/icvts/ivac234

Vancouver

Messina G, Bove M, Natale G, Noro A, Martone M, Opromolla G, et al. Ultrasound location of ground-glass opacity during thoracoscopic surgery. Interactive CardioVascular and Thoracic Surgery. 2022;35(6). doi:10.1093/icvts/ivac234

BibTeX
@article{Messina2022,
  author = {Messina, Gaetana and Bove, Mary and Natale, Giovanni and Noro, Antonio and Martone, Mario and Opromolla, Giorgia and Di Filippo, Vincenzo and Leonardi, Beatrice and Fasano, Morena and Polito, Rita and Fiorelli, Alfonso and Santini, Mario and Vicidomini, Giovanni},
  title = {Ultrasound location of ground-glass opacity during thoracoscopic surgery},
  journal = {Interactive CardioVascular and Thoracic Surgery},
  year = {2022},
  volume = {35},
  number = {6},
  doi = {10.1093/icvts/ivac234}
}
Kostenlos starten →