EUVIMEDEUVIMED entdecken
Crossref

L26/P-882 Risk-Based Environmental Microbiological Monitoring in IVF Laboratories: A Multicenter Study

L. De Santis, L. Perego, A. Frezza, C. Colasante, P. Testa, M. Santoli, A. Mangiarini, S. Ferrari, V. Iommiello, I. Mondini, G. Tesoriere, A. Cesana und 3 weitere

Human Reproduction · 01.07.2026 · 41 (Supplement_1)

DOI: 10.1093/humrep/deag083.1206 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Human Reproduction, online erschienen am 08.07.2026. Verfasst von L. De Santis und 14 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Study question What is the procedure-specific risk of environmental microbiological contamination during routine IVF laboratory activities performed under different cleanroom classifications? Summary answer Environmental microbiological contamination risk differs markedly across IVF procedures and is substantially higher for procedures performed in Grade D compared with Grade A environments. What is known already Environmental microbiological monitoring is mandatory in IVF laboratories under European regulations, including the EDQM Guide and EU GMP Annex 1. Airborne microbial contamination may negatively affect gametes and embryos, and monitoring is commonly performed using passive and active air sampling. However, current recommendations are largely generic and do not adequately address the heterogeneity of IVF laboratory procedures. To date, no multicenter study has systematically quantified procedure-specific environmental contamination risks across the entire medically assisted reproduction workflow. Study design, size, duration Multicenter observational study including nine IVF laboratories in Northern Italy. Environmental air monitoring data were collected during routine IVF procedures between 2023 and 2025, yielding a total of 2,146 sentinel settle plates. Participants/materials, setting, methods Passive air monitoring was performed using irradiated TSA settle plates positioned near the working area during seven IVF laboratory procedures conducted in either Grade A or Grade D environments. Plates were incubated at two temperatures to detect bacterial and fungal growth. Contamination risk was defined as the proportion of plates with ≥1 CFU, with exact 95% confidence intervals. Cumulative contamination probabilities were estimated assuming independence between procedures. Main results and the role of chance Overall contamination risk varied significantly by procedure and environmental grade. Procedures performed in Grade D environments (ICSI and embryo biopsy) showed a markedly higher contamination probability compared with Grade A procedures (26.0% vs 2.2%; p < 0.001). ICSI was associated with the highest contamination risk. When considering the procedural set including only class A procedures (sperm preparation, oocyte retrieval, oocyte denuding, embryo vitrification, and embryo transfer), the cumulative probability of detecting at least one positive sentinel plate was 11.2% (95% CI: 7.9–14.6%). The inclusion of ICSI resulted in a marked increase in cumulative contamination risk to 33.2% (95% CI: 24.0–41.5%). When all monitored procedures were considered, including both class A and class D procedures, the cumulative probability of observing at least one contaminated sentinel plate reached 47.3% (95% CI: 29.2–61.9%)Exposure time was not associated with contamination risk for Grade A procedures, whereas a significant time-dependent increase was observed when Grade D procedures were included (p < 0.001). Most positive plates showed minimal contamination, with single-colony growth predominating. Limitations, reasons for caution Settle plates are surrogate indicators of environmental contamination and do not directly measure contamination of gametes or embryos. Cumulative risk estimates assume independence between procedural steps. Wider implications of the findings Environmental microbiological risk in IVF laboratories is highly procedure-dependent and primarily driven by environmental grade. These findings support a risk-based, procedure-specific approach to environmental monitoring, particularly for procedures performed in Grade D environments. Trial registration number No

Zitieren

APA

Santis, L. D., Perego, L., Frezza, A., Colasante, C., Testa, P., Santoli, M., Mangiarini, A., Ferrari, S., Iommiello, V., Mondini, I., Tesoriere, G., Cesana, A., Corti, L., Viganò, P., & Paffoni, A. (2026). L26/P-882 Risk-Based Environmental Microbiological Monitoring in IVF Laboratories: A Multicenter Study. Human Reproduction, 41(Supplement_1). https://doi.org/10.1093/humrep/deag083.1206

Vancouver

Santis LD, Perego L, Frezza A, Colasante C, Testa P, Santoli M, et al. L26/P-882 Risk-Based Environmental Microbiological Monitoring in IVF Laboratories: A Multicenter Study. Human Reproduction. 2026;41(Supplement_1). doi:10.1093/humrep/deag083.1206

BibTeX
@article{Santis2026,
  author = {Santis, L. De and Perego, L. and Frezza, A. and Colasante, C. and Testa, P. and Santoli, M. and Mangiarini, A. and Ferrari, S. and Iommiello, V. and Mondini, I. and Tesoriere, G. and Cesana, A. and Corti, L. and Viganò, P. and Paffoni, A.},
  title = {L26/P-882 Risk-Based Environmental Microbiological Monitoring in IVF Laboratories: A Multicenter Study},
  journal = {Human Reproduction},
  year = {2026},
  volume = {41},
  number = {Supplement_1},
  doi = {10.1093/humrep/deag083.1206}
}
Kostenlos starten →