Evaluation of the dual-action tissue closure device for perforation closure after endoscopic full-thickness resection of gastric submucosal tumors >10 mm
Gastroenterology Report · 20.01.2026 · 14
DOI: 10.1093/gastro/goag070 ↗Kurz gefasst
Fachartikel in der Zeitschrift Gastroenterology Report, online erschienen am 21.07.2026. Verfasst von Lingjun Meng und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Nanfang Hospital, Southern Medical University, 1838 Guangzhou Avenue North, Baiyun District, Guangzhou, Guangdong, Ch…. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Provincial Science and Technology Award.
Abstract (Originalsprache)
Background
Endoscopic full-thickness resection (EFTR) is an effective technique for endoscopic resection of gastric submucosal tumors (G-SMTs); however, the closure of the post-operative perforation wound presents a significant challenge. We invented a dual action tissue closure device (DAT), and aimed to evaluate its feasibility and safety in closing perforation wounds following EFTR of G-SMTs.
Methods
This is a retrospective study that included the data of patients who underwent EFTR for G-SMTs at Nanfang Hospital (Guangzhou, China) between 1 January 2021 and 1 April 2024. All these wounds were closed using the DAT and through-the-scope clip. The collected data included tumor size and location, total procedure time, closure success rate, closure time, complications, and follow-up outcomes. The closure efficacy of the DAT was evaluated accordingly.
Results
Twenty-nine patients (median age, 57 years old, 37.9% women) completed EFTR of G-SMTs, which included 2 cases utilizing cap-assisted full-thickness resection and 27 cases using EFTR. The tumors had a median long diameter of 20 (15–30) mm and short diameter of 15 (10–25) mm. All wounds were successfully closed without complications. The median total operation time was 55 minutes (interquartile range: 33.5–70.0 minutes), and the median wound closure time was 19 minutes (range: 12.0–27.0 minutes). The median number of DAT used was 1 (interquartile range: 1–3), with a median operation time of 3 minutes (1.6–6.5) for per DAT. Seven patients underwent endoscopic follow-up, with 88.2% of the DATs falling off naturally.
Conclusions
DAT can effectively and safely close perforation wounds following EFTR of G-SMTs.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Gastroenterology, Nanfang Hospital, Southern Medical University, 1838 Guangzhou Avenue North, Baiyun District, Guangzhou, Guangdong, China.
- Department of Gastroenterology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou Medical University, 151 Yanjiang West Road, Yuexiu District, Guangzhou, Guangdong, China.
- Department of Gastroenterology, Zengcheng Branch, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China.
ORCID-Profile: Lingjun Meng, Qiang Zhang
Förderung
- National Natural Science Foundation of China
- Provincial Science and Technology Award
Zitieren
APA
Meng, L., Cai, J., Wang, Z., Zhang, B., Gao, Z., Chen, J., Zhang, D., Liu, P., Xing, T., Xu, Y., Wang, S., Meng, Y., Liu, S., & Zhang, Q. (2026). Evaluation of the dual-action tissue closure device for perforation closure after endoscopic full-thickness resection of gastric submucosal tumors >10 mm. Gastroenterology Report, 14. https://doi.org/10.1093/gastro/goag070
Vancouver
Meng L, Cai J, Wang Z, Zhang B, Gao Z, Chen J, et al. Evaluation of the dual-action tissue closure device for perforation closure after endoscopic full-thickness resection of gastric submucosal tumors >10 mm. Gastroenterology Report. 2026;14. doi:10.1093/gastro/goag070
BibTeX
@article{Meng2026,
author = {Meng, Lingjun and Cai, Jianqun and Wang, Zhen and Zhang, Baohua and Gao, Zhiru and Chen, Jihua and Zhang, Dongbo and Liu, Panpan and Xing, Tongyin and Xu, Yan and Wang, Shanci and Meng, Yan and Liu, Side and Zhang, Qiang},
title = {Evaluation of the dual-action tissue closure device for perforation closure after endoscopic full-thickness resection of gastric submucosal tumors >10 mm},
journal = {Gastroenterology Report},
year = {2026},
volume = {14},
doi = {10.1093/gastro/goag070}
}
EUVIMED