Endoscopic ultrasound versus direct transjugular portal pressure gradient in patients receiving TIPS: influence of portal vein thrombosis
Gastroenterology Report · 20.01.2026 · 14
DOI: 10.1093/gastro/goag052 ↗Kurz gefasst
Fachartikel in der Zeitschrift Gastroenterology Report, online erschienen am 29.05.2026. Verfasst von Irina Dragomir und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Regional Institute of Gastroenterology and Hepatology "Prof. Dr. Octavian Fodor", Cluj-Napoca, Cluj 400162, Romania. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Iuliu Hatieganu.
Abstract (Originalsprache)
Background
Endoscopic ultrasound (EUS) has emerged as a valuable tool for assessing portal hypertension (PH). Our study aimed to compare endoscopic ultrasound-guided portal pressure gradient (EUS-PPG) with directly measured transjugular PPG (T-PPG) and hepatic venous pressure gradient (HVPG) during transjugular intrahepatic portosystemic shunt (TIPS).
Methods
Consecutive patients scheduled for elective TIPS between March 2023 and December 2024 were included. EUS was performed using a 22-gauge FNA needle attached to an invasive pressure monitoring module. TIPS placement and HVPG were performed according to the standard methods.
Results
Twenty-four patients who underwent elective TIPS for PH-related complications were enrolled (mean age 56.4 ± 8.8 years, model of end-stage liver disease [MELD] 15.0 ± 5.5). The technical success rates for EUS-PPG and HVPG were 92.3% and 100%, respectively. There was a strong correlation between EUS-PPG and T-PPG (r = 0.88, P < 0.01; intra-class correlation coefficient [ICC] = 0.930, 95% CI 0.837–0.970) and a moderate correlation between EUS-PPG and HVPG (r = 0.58, P < 0.05; ICC = 0.735, 95% CI 0.311–0.898). The presence of portal vein thrombosis (PVT) was independently associated with a ≥ 3 mmHg difference between EUS-PPG and T-PPG (P = 0.04). Child-Pugh score was independently associated with a ≥ 3 mmHg difference between EUS-PPG and HVPG (P = 0.01). Two minor adverse effects were reported.
Conclusion
EUS-PPG demonstrates strong reliability when compared to direct PPG measurements obtained during TIPS insertion. Using a 22-gauge needle, EUS-PPG proved to be accurate and safe for assessing PH. The presence of PVT may be a cofounder of discrepancy between the direct methods.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Gastroenterology, Regional Institute of Gastroenterology and Hepatology "Prof. Dr. Octavian Fodor", Cluj-Napoca, Cluj 400162, Romania.
- Department IV, Third Medical Clinic, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Cluj 400012, Romania.
- Department of Clinical Psychology and Psychotherapy, International Institute for Advanced Study of Psychotherapy and Applied Mental Health, Babes-Bolyai University, Cluj-Napoca, Cluj 400084, Romania.
- Department of Medical Informatics and Biostatistics, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Cluj 400012, Romania.
- Department of Anesthesia and Intensive Care I, "Iuliu Haţieganu" University of Medicine and Pharmacy, Cluj-Napoca, Cluj 400012, Romania.
- Department of Anesthesia, Regional Institute of Gastroenterology and Hepatology "Prof. Dr. Octavian Fodor", Cluj-Napoca, Cluj 400162, Romania.
ORCID-Profile: Irina Dragomir, Horia Stefanescu
Förderung
- Iuliu Hatieganu
Zitieren
APA
Dragomir, I., Pojoga, C., Hagiu, C., Bolboacă, S. D., Alexa, A., Nicoara-Farcau, O., Fischer, P., Stefanescu, H., Procopet, B., & Seicean, A. (2026). Endoscopic ultrasound versus direct transjugular portal pressure gradient in patients receiving TIPS: influence of portal vein thrombosis. Gastroenterology Report, 14. https://doi.org/10.1093/gastro/goag052
Vancouver
Dragomir I, Pojoga C, Hagiu C, Bolboacă SD, Alexa A, Nicoara-Farcau O, et al. Endoscopic ultrasound versus direct transjugular portal pressure gradient in patients receiving TIPS: influence of portal vein thrombosis. Gastroenterology Report. 2026;14. doi:10.1093/gastro/goag052
BibTeX
@article{Dragomir2026,
author = {Dragomir, Irina and Pojoga, Cristina and Hagiu, Claudia and Bolboacă, Sorana D and Alexa, Alexandru and Nicoara-Farcau, Oana and Fischer, Petra and Stefanescu, Horia and Procopet, Bogdan and Seicean, Andrada},
title = {Endoscopic ultrasound versus direct transjugular portal pressure gradient in patients receiving TIPS: influence of portal vein thrombosis},
journal = {Gastroenterology Report},
year = {2026},
volume = {14},
doi = {10.1093/gastro/goag052}
}
EUVIMED