EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Reported Cryptococcus neoformans heat-killing protocols show incomplete killing

Binyi An, Yingjun Gao, Yingying Wu, Yubing Wu, Xiaoyu Wang iD, Qingtao Kong, Hong Sang, Haibo Liu iD

FEMS Microbes · 08.01.2026 · 7

DOI: 10.1093/femsmc/xtag031 ↗

Kurz gefasst

Fachartikel in der Zeitschrift FEMS Microbes, online erschienen am 18.06.2026. Verfasst von Binyi An und 7 weiteren Autor:innen. Beteiligte Einrichtung: Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing 210002, China. Die Arbeit nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Heat killing is commonly employed to kill microorganisms, including Cryptococcus neoformans (C. neoformans), particularly in immunological studies and vaccine development. To assess the reliability of existing methods, we systematically reviewed 50 publications and identified 23 distinct protocols differing in temperature, duration, suspension concentration, and sample volume. Using two virulent strains, H99 and B3501, we experimentally tested these conditions and found that only 9 protocols achieved complete (100%) killing, whereas 14 resulted in partial killing. Consistent with this, only 17 publications (34%) reported complete killing, and just 20 studies described plating suspensions for validation, raising concerns that incomplete killing may have gone undetected. Further analysis revealed that suspension volume and fungal concentration critically influenced outcomes. These findings highlight substantial variability and insufficient validation across reported protocols, which may undermine reproducibility and biosafety. Our study provides evidence-based guidance for selecting effective heat-killing conditions, thereby supporting safer and more reliable use of heat-killed C. neoformans in experimental research.

Schlagwörter

Stichwörter der Autor:innen

Cryptococcus neoformansheat-killingmicrobial killingprotocol standardization

Autor:innen und Institutionen

  • Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing 210002, China.
  • Department of Plastic and Cosmetic Surgery, Women's Hospital of Nanjing Medical University (Nanjing Women and Children's Healthcare Hospital), Nanjing 210001, China.

ORCID-Profile: Xiaoyu Wang, Haibo Liu

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

An, B., Gao, Y., Wu, Y., Wu, Y., Wang, X., Kong, Q., Sang, H., & Liu, H. (2026). Reported Cryptococcus neoformans heat-killing protocols show incomplete killing. FEMS Microbes, 7. https://doi.org/10.1093/femsmc/xtag031

Vancouver

An B, Gao Y, Wu Y, Wu Y, Wang X, Kong Q, et al. Reported Cryptococcus neoformans heat-killing protocols show incomplete killing. FEMS Microbes. 2026;7. doi:10.1093/femsmc/xtag031

BibTeX
@article{An2026,
  author = {An, Binyi and Gao, Yingjun and Wu, Yingying and Wu, Yubing and Wang, Xiaoyu and Kong, Qingtao and Sang, Hong and Liu, Haibo},
  title = {Reported Cryptococcus neoformans heat-killing protocols show incomplete killing},
  journal = {FEMS Microbes},
  year = {2026},
  volume = {7},
  doi = {10.1093/femsmc/xtag031}
}
Kostenlos starten →