Construction and validation of an Escherichia coli whole-cell biosensor based on CadC and GFP for heavy metal detection
FEMS Microbiology Letters · 07.01.2026 · 373
DOI: 10.1093/femsle/fnag082 ↗Kurz gefasst
Fachartikel in der Zeitschrift FEMS Microbiology Letters, online erschienen am 17.07.2026. Verfasst von Dissanayake Mudiyanselage Dilani Chathurika Dissanayake und 3 weiteren Autor:innen. Beteiligte Einrichtung: Biotechnology Laboratory, Department of Chemistry, Faculty of Science, University of Colombo, Colombo 003, Sri Lanka. Hauptthemen laut MEDLINE: Biosensing Techniques, Escherichia coli, Green Fluorescent Proteins, Metals, Heavy. Die Arbeit nennt 36 Literaturangaben. Gefördert von: National Science Foundation of Sri Lanka, University of Colombo.
Abstract (Originalsprache)
Whole-cell biosensors provide a cost-effective and sensitive approach for real-time monitoring of toxic metals in environmental samples. In this study, a bacterial whole-cell biosensor was engineered using Escherichia coli BL21(DE3) by integrating the cadC regulatory gene from Bacillus megaterium TWSL_4 with a green fluorescent protein (GFP) reporter to enable fluorescence-based detection of heavy metals. The biosensor gene cassette (Pcad + cadC + gfp) was first cloned into the pUC19 vector and then subcloned into the pET28a(+) expression vector to generate the recombinant plasmid pETCG28. Functional characterization showed that the engineered strain E. coli BL21/pETCG28 exhibited enhanced tolerance to heavy metals, sustaining growth at Pb²⁺ concentrations up to 1600 ppm, Cd²⁺ up to 200 ppm, and Zn²⁺ up to 60 ppm, significantly higher than the wild-type strain. Fluorescence analyses demonstrated strong concentration-dependent responses to heavy metal exposure. Corrected total cell fluorescence increased nearly fourfold between 1 ppb and 10 ppb of Pb²⁺ (R² = 0.95, P < 0.0001). Cd²⁺ exposure produced an approximately threefold increase (R² = 0.96, P < 0.0001), while Zn²⁺ generated a moderate twofold response (R² = 0.94, P < 0.0001). Optimal biosensor performance occurred at pH 7.0 and 37°C, demonstrating potential for portable environmental monitoring applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Biotechnology Laboratory, Department of Chemistry, Faculty of Science, University of Colombo, Colombo 003, Sri Lanka.
- Department of Life Science and Technology, Institute of Science Tokyo, Yokohama, 226-8501, Japan.
ORCID-Profile: Dissanayake Mudiyanselage Dilani Chathurika Dissanayake, Masaaki Wachi, Champika Dilrukshi Wijayarathna
Förderung
- National Science Foundation of Sri Lanka
- University of Colombo
Zitieren
APA
Dissanayake, D. M. D. C., Chandrasekharan, N. V., Wachi, M., & Wijayarathna, C. D. (2026). Construction and validation of an Escherichia coli whole-cell biosensor based on CadC and GFP for heavy metal detection. FEMS Microbiology Letters, 373. https://doi.org/10.1093/femsle/fnag082
Vancouver
Dissanayake DMDC, Chandrasekharan NV, Wachi M, Wijayarathna CD. Construction and validation of an Escherichia coli whole-cell biosensor based on CadC and GFP for heavy metal detection. FEMS Microbiology Letters. 2026;373. doi:10.1093/femsle/fnag082
BibTeX
@article{Dissanayake2026,
author = {Dissanayake, Dissanayake Mudiyanselage Dilani Chathurika and Chandrasekharan, Naduviladath Vishvanath and Wachi, Masaaki and Wijayarathna, Champika Dilrukshi},
title = {Construction and validation of an Escherichia coli whole-cell biosensor based on CadC and GFP for heavy metal detection},
journal = {FEMS Microbiology Letters},
year = {2026},
volume = {373},
doi = {10.1093/femsle/fnag082}
}
EUVIMED