EUVIMEDEUVIMED entdecken
Systematische Übersicht

Point-of-care ultrasound to assess left ventricular ejection fraction in heart failure in unselected patients in primary care: a systematic review

Point-of-care-Ultraschall zur Beurteilung der linksventrikulären Ejektionsfraktion bei Herzinsuffizienz bei unselektierten Patient:innen in der Primärversorgung: systematische Übersicht

Perrine Allimant iD, Lucas Guillo, Thomas Fierling, Andry Rabiaza, Isabelle Cibois-Honnorat

Family Practice · 07.02.2025 · 42 (2)

DOI: 10.1093/fampra/cmae040 ↗

Auf einen Blick

42 Studien zeigen: Nicht-expert:innen konnten die LVEF mit kardialem POCUS in unselektierten Patient:innen meist mit guter Übereinstimmung einschätzen. Die Messung dauerte median 8 Minuten.

Fragestellung

Wie gut lässt sich die linksventrikuläre Ejektionsfraktion bei unselektierten Patient:innen in der Primärversorgung mit kardialem POCUS durch Nicht-Expert:innen beurteilen?

Methode

Systematische Übersicht; Suche in Medline, Embase und Pubmed bis Januar 2024 nach interventionalen und nicht-interventionalen Studien zu cPOCUS bei vermuteter oder diagnostizierter HF.

Ergebnisse

42 Studien mit 6598 Patient:innen; 60,2 % ambulant. LVEF durch 351 Nicht-Expert:innen nach Schulung beurteilt; visuelle Einschätzung in 90,2 %. Übereinstimmung: κ = 0,72 [0,63; 0,83] bzw. κ = 0,84 [0,71; 0,89].

Schlussfolgerung der Autor:innen

Der Einsatz von cPOCUS durch Nicht-Expert:innen nach kurzer Schulung erscheint als akkurates ergänzendes Verfahren zur LVEF-Beurteilung im Alltag. Eine Verbreitung in der Primärversorgung könnte das Management optimieren, ohne die Spezialist:innenbeurteilung zu ersetzen.

Kernaussagen

  • LVEF-Bewertung meist per visueller Einschätzung
  • Median 8 Minuten pro cPOCUS-Untersuchung
  • Übereinstimmung mit Expert:innen bis κ = 0,84

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Systematische Übersicht in der Zeitschrift Family Practice, online erschienen am 20.08.2024. Verfasst von Perrine Allimant und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Medicine, University of Aix-Marseille, Marseille, France. Hauptthemen laut MEDLINE: Heart Failure, Stroke Volume, Point-of-Care Systems, Echocardiography. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 82 Literaturangaben.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Heart failure (HF) is the most frequent cardiovascular pathology in primary care. Echocardiography is the gold standard for diagnosis, follow-up, and prognosis of HF. Point-of-care ultrasound (POCUS) is of growing interest in daily practice.

Aim

This study aimed to systematically review the literature to evaluate left ventricular ejection fraction (LVEF) assessment of unselected patients in primary care by non-expert physicians with cardiac POCUS (cPOCUS).

Methods

We searched in Medline, Embase, and Pubmed up to January 2024 for interventional and non-interventional studies assessing LVEF with cPOCUS in unselected patients with suspected or diagnosed HF in hospital or outpatient settings, performed by non-expert physicians.

Results

Forty-two studies were included, involving 6598 patients, of whom 60.2% were outpatients. LVEF was assessed by 351 non-expert physicians after an initial ultrasound training course. The LVEF was mainly assessed by visual estimation (90.2%). The most frequent views were parasternal long/short axis, and apical 4-chamber. The median time of cPOCUS was 8 minutes. A strong agreement was found (κ = 0.72 [0.63; 0.83]) compared to experts when using different types of ultrasound devices (hand-held and standard), and agreement was excellent (κ = 0.84 [0.71; 0.89]) with the same device. Training course combined a median of 4.5 hours for theory and 25 cPOCUS for practice.

Conclusion

The use of cPOCUS by non-expert physicians after a short training course appears to be an accurate complementary tool for LVEF assessment in daily practice. Its diffusion in primary care could optimize patient management, without replacing specialist assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart FailureStroke VolumePoint-of-Care SystemsEchocardiographyHumansPrimary Health CareUltrasonography

Stichwörter der Autor:innen

echocardiographyheart failureleft ventricular ejection fractionpoint-of-care ultrasoundprimary health careprimary-care physicians

Autor:innen und Institutionen

  • Department of General Medicine, University of Aix-Marseille, Marseille, France.
  • Department of Gastroenterology, University Hospital of Marseille Nord, University of Aix-Marseille, Marseille, France.
  • Department of General Medicine, CERESS, University of Aix-Marseille University, Marseille, France.
  • Department of General Medicine, UNICAEN, University of Caen Normandy, Caen, France.
  • Department of General Medicine, Snecho-MG, Aix-Marseille University, Marseille, France.

ORCID-Profile: Perrine Allimant

Zitieren

APA

Allimant, P., Guillo, L., Fierling, T., Rabiaza, A., & Cibois-Honnorat, I. (2025). Point-of-care ultrasound to assess left ventricular ejection fraction in heart failure in unselected patients in primary care: a systematic review. Family Practice, 42(2). https://doi.org/10.1093/fampra/cmae040

Vancouver

Allimant P, Guillo L, Fierling T, Rabiaza A, Cibois-Honnorat I. Point-of-care ultrasound to assess left ventricular ejection fraction in heart failure in unselected patients in primary care: a systematic review. Family Practice. 2025;42(2). doi:10.1093/fampra/cmae040

BibTeX
@article{Allimant2025,
  author = {Allimant, Perrine and Guillo, Lucas and Fierling, Thomas and Rabiaza, Andry and Cibois-Honnorat, Isabelle},
  title = {Point-of-care ultrasound to assess left ventricular ejection fraction in heart failure in unselected patients in primary care: a systematic review},
  journal = {Family Practice},
  year = {2025},
  volume = {42},
  number = {2},
  doi = {10.1093/fampra/cmae040}
}
Kostenlos starten →