EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Pacing Performance of a Modular Communicative Leadless Pacing-Defibrillator System

Lluís Mont iD, Michael S Lloyd iD, Paul R Roberts iD, Rahul Doshi iD, David J Wright iD, Paul A Friedman iD, Petr Neuzil iD, Carina Blomstrom-Lundqvist iD, Maria Grazia Bongiorni iD, Martin Burke iD, Daniel Gras iD, Steven P Kutalek iD und 12 weitere

Europace · 05.11.2026

DOI: 10.1093/europace/euag309 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Europace, online erschienen am 05.11.2026. Verfasst von Lluís Mont und 23 weiteren Autor:innen. Beteiligte Einrichtung: Institut Clínic Cardiovascular, Hospital Clínic, Universitat de Barcelona. Barcelona, Spain. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Aims MODULAR ATP is an ongoing trial assessing the efficacy of a subcutaneous implantable cardioverter defibrillator (S-ICD) in communication with a leadless pacemaker (LP) that can deliver bradycardia pacing and antitachycardia pacing. The objective of this study was to assess safety and pacing performance of the investigational LP.

Methods

The study enrolled patients with an ICD indication and at high risk for monomorphic ventricular tachycardia. Pacemaker dependent patients were excluded. Primary safety endpoint 2 was the percentage of patients free from major LP-related complications at 12 months. The secondary effectiveness endpoint assessed the rate response performance of the LP under workload. Parameters related to the pacing performance were also measured.

Results

In 297 patients, the mean age was 59±12 years, the mean left ventricular ejection fraction was 35.3±13.1%, and 17.5% were female. LP implant was attempted in 286 patients and was successful in 100%. The major LP-related complication free rate at 12 months was 97.2% (one-sided 97.5% LCL 94.5%), surpassing the performance goal of 81%. There were no LP-related complications following Implant. For the secondary effectiveness endpoint, the slope of the normalized sensor rate versus the normalized workload was 0.96 (95% LCL 0.91, 95% UCL 1.02), within the performance goal range of 0.65-1.35. At 12 months, 96.8% of patients had a pacing capture threshold ≤ 2V @ 0.4ms pulse width.

Conclusions

The performance of the modular pacing-defibrillator system at one year demonstrated a low complication rate and reliable pacing functionality.

Schlagwörter

Stichwörter der Autor:innen

Leadless pacemakerpacing performancerate responsesubcutaneous ICD

Autor:innen und Institutionen

  • Institut Clínic Cardiovascular, Hospital Clínic, Universitat de Barcelona. Barcelona, Spain.
  • Emory University Section of Cardiac Electrophysiology, Atlanta, GA, USA.
  • University Hospital Southampton, Southampton, United Kingdom.
  • Institute John Schufeldt ASU School of Medicine and Medical Engineering and HonorHealth, Scottsdale, AZ, USA.
  • Department of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, United Kingdom.
  • Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA.

ORCID-Profile: Lluís Mont, Michael S Lloyd, Paul R Roberts, Rahul Doshi, David J Wright, Paul A Friedman, Petr Neuzil, Carina Blomstrom-Lundqvist, Maria Grazia Bongiorni, Martin Burke, Daniel Gras, Steven P Kutalek, Harish Manyam, Wilber Su, Gerardo Nigro, Tara Bachman, Reinoud E Knops, Vivek Y Reddy

Zitieren

APA

Mont, L., Lloyd, M. S., Roberts, P. R., Doshi, R., Wright, D. J., Friedman, P. A., Neuzil, P., Blomstrom-Lundqvist, C., Bongiorni, M. G., Burke, M., Gras, D., Kutalek, S. P., Plourde, B., Merchant, F. M., Manyam, H., Su, W., Nigro, G., Dunmire, S. K., Appl, U., …, & Reddy, V. Y. (2026). Pacing Performance of a Modular Communicative Leadless Pacing-Defibrillator System. Europace. https://doi.org/10.1093/europace/euag309

Vancouver

Mont L, Lloyd MS, Roberts PR, Doshi R, Wright DJ, Friedman PA, et al. Pacing Performance of a Modular Communicative Leadless Pacing-Defibrillator System. Europace. 2026. doi:10.1093/europace/euag309

BibTeX
@article{Mont2026,
  author = {Mont, Lluís and Lloyd, Michael S and Roberts, Paul R and Doshi, Rahul and Wright, David J and Friedman, Paul A and Neuzil, Petr and Blomstrom-Lundqvist, Carina and Bongiorni, Maria Grazia and Burke, Martin and Gras, Daniel and Kutalek, Steven P and Plourde, Benoit and Merchant, Faisal M and Manyam, Harish and Su, Wilber and Nigro, Gerardo and Dunmire, Samantha K and Appl, Ursula and Carter, Nathan and Swackhamer, Bryan and Bachman, Tara and Knops, Reinoud E and Reddy, Vivek Y},
  title = {Pacing Performance of a Modular Communicative Leadless Pacing-Defibrillator System},
  journal = {Europace},
  year = {2026},
  doi = {10.1093/europace/euag309}
}
Kostenlos starten →