Background

Transcatheter aortic valve implantation (TAVI) may lead to permanent pacemaker (PPM) implantation in 5–20% of patients. While the percentage of ventricular pacing (%VP) has been widely studied, the relationship between AAI–DDD mode switches and atrioventricular block (AVB) remains poorly characterized. Objective/Purpose To assess the percentage of VP and the occurrence of AVB-related AAI–DDD mode switches in patients undergoing TAVI who required a PPM.

Methods

We included 62 consecutive TAVI patients requiring PPM implantation. Devices were programmed in AAI–DDD mode using an algorithm to monitor mode switches and their causes. The %VP, type of switch, and their association with baseline clinical and electrophysiological characteristics were analyzed.

Results

Among 62 patients, 55% received a PPM for persistent high degree AVB, 3% for alternating bundle branch block, 34% for new LBB (left bundle brunch) with QRS >150 ms or PR >240 ms, and 8% for PR/QRS prolongation >20 ms from already prolonged baseline values. Figure1. During a follow-up of 96 ± 37 days, %VP was high (≥10%) in 40% of patients, intermediate (1–9%) in 18%, and low (≤1%) in 42%. Significant AAI–DDD switches (2nd, 3rd AVB and pause > 3 seconds) occurred in 86% of patients, more frequently in those with persistent AVB (94%), alternating bundle branch block (100%), than PR/QRS prolongation (80%) and new LBB with QRS >150 ms or PR >240 ms (71%), p=0,119. Predictors of mode switching included hypertension and temporary pacemaker requirement. Hypertension, temporary pacemaker requirement, right bundle branch block and persistent high degree AVB predicted higher %VP.

Conclusion

Although elevated %VP (>10%) was observed in only 40% of patients, up to 86% experienced mode switches, underscoring the importance of evaluating AAI–DDD algorithms beyond %VP alone.Baseline characteristics.Abstract.

Zitieren

APA

Manchon, J. N., Garcia, G. R., Francisco, M. I. D., Perez, O. C., Navarrete-Navarro, J., Martinez, C. A., Perez, E. R., Montoro, S. H., Ortiz, N. F., Garcia, J. L., Alfonso, V. V. S., Molina, M. G., Varona, G. M., Dolz, L. M., & Asensi, J. O. (2026). Evaluation of DDD pacemaker mode switching in TAVI Patients: does a low ventricular pacing percentage mean it was unnecessary?. Europace, 28(Supplement_1). https://doi.org/10.1093/europace/euag105.702

Vancouver

Manchon JN, Garcia GR, Francisco MID, Perez OC, Navarrete-Navarro J, Martinez CA, et al. Evaluation of DDD pacemaker mode switching in TAVI Patients: does a low ventricular pacing percentage mean it was unnecessary?. Europace. 2026;28(Supplement_1). doi:10.1093/europace/euag105.702

BibTeX
@article{Manchon2026,
  author = {Manchon, J Navarro and Garcia, G Rad and Francisco, M Izquierdo De and Perez, O Cano and Navarrete-Navarro, J and Martinez, C Arveras and Perez, E Robles and Montoro, S Huelamo and Ortiz, N Fernandez and Garcia, J Llau and Alfonso, V V Soriano and Molina, M Gil and Varona, G Murillo and Dolz, L Martinez and Asensi, J Osca},
  title = {Evaluation of DDD pacemaker mode switching in TAVI Patients: does a low ventricular pacing percentage mean it was unnecessary?},
  journal = {Europace},
  year = {2026},
  volume = {28},
  number = {Supplement_1},
  doi = {10.1093/europace/euag105.702}
}
Kostenlos starten →