EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Safety and feasibility of leadless pacemaker implantation in elderly small-framed asian patients: a multicenter retrospective study

M Asami, Y Enomoto, J Yamamoto, T Shimizu, N Sahara, N Nemoto, K Nakamura, H Hara

Europace · 25.06.2026 · 28 (Supplement_1)

DOI: 10.1093/europace/euag105.696 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Europace, online erschienen am 25.06.2026. Verfasst von M Asami und 7 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Leadless pacemaker (LPM) therapy eliminates pocket- and lead-related complications of transvenous systems, however its large delivery sheath may raise safety concerns in small-framed elderly Asian patients. Data in this population remain scarce.

Aim

To assess the procedural safety, feasibility, and short-term outcomes of LPM implantation in elderly Asian patients, and to compare them with transvenous single-chamber pacemakers (TV-PM).

Methods

We retrospectively analyzed 149 consecutive patients (90 LPM, 59 TV-PM) aged ≥80 years who underwent pacemaker implantation at three Japanese centers between 2010 and 2021. Primary endpoints were procedural safety and feasibility. Secondary endpoints included all-cause mortality, heart-failure hospitalization, and device-related complications within 2 years Results Median age was 90 [83–94] vs 84 [83–95] years; mean height 148.8 ± 9.7 vs 155.8 ± 12.2 cm, confirming a smaller body habitus in this Asian cohort. LVEF was similar (60.0% vs 64.5%, p = 0.16), but renal dysfunction was more common in TV-SPM (76.3% vs 46.7%, p < 0.001). All implantations were successful. Despite frailty and smaller anatomy, LPM procedures were shorter (55.7 ± 25.8 vs 78.5 ± 15.8 min, p = 0.008) and required fewer prolonged hospitalizations (>48 h beyond plan: 48.9% vs 64.4%, p = 0.05). Major complications were infrequent and comparable (5.6% vs 11.9%, p = 0.14).

Conclusion

LPM implantation is safe and feasible even in frail, small-framed Asian octogenarians. These findings suggest that LPM can overcome anatomical and procedural limitations of transvenous systems, supporting broader adoption in aging Asian populations.

Zitieren

APA

Asami, M., Enomoto, Y., Yamamoto, J., Shimizu, T., Sahara, N., Nemoto, N., Nakamura, K., & Hara, H. (2026). Safety and feasibility of leadless pacemaker implantation in elderly small-framed asian patients: a multicenter retrospective study. Europace, 28(Supplement_1). https://doi.org/10.1093/europace/euag105.696

Vancouver

Asami M, Enomoto Y, Yamamoto J, Shimizu T, Sahara N, Nemoto N, et al. Safety and feasibility of leadless pacemaker implantation in elderly small-framed asian patients: a multicenter retrospective study. Europace. 2026;28(Supplement_1). doi:10.1093/europace/euag105.696

BibTeX
@article{Asami2026,
  author = {Asami, M and Enomoto, Y and Yamamoto, J and Shimizu, T and Sahara, N and Nemoto, N and Nakamura, K and Hara, H},
  title = {Safety and feasibility of leadless pacemaker implantation in elderly small-framed asian patients: a multicenter retrospective study},
  journal = {Europace},
  year = {2026},
  volume = {28},
  number = {Supplement_1},
  doi = {10.1093/europace/euag105.696}
}
Kostenlos starten →