EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Feasibility of mapping and ablation of atypical atrial flutter using a lattice-tip catheter toggling between radiofrequency and pulsed field energy

E Chiarazzo, M Marino, V M La Fazia, C Gianni, S Mohanty, G Stifano, W Bode, K Awad, D Burkhardt, J Gallinghouse, R P Horton, A Al-Ahmad und 2 weitere

Europace · 25.06.2026 · 28 (Supplement_1)

DOI: 10.1093/europace/euag105.577 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Europace, online erschienen am 25.06.2026. Verfasst von E Chiarazzo und 13 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Atypical atrial flutter (AAFL) comprises complex macro-reentrant atrial arrhythmias arising from areas of scar or slow conduction following prior ablation, cardiac surgery, or atrial cardiomyopathy. Three-dimensional electroanatomic mapping (3D-EAM) is essential to define these circuits.

Purpose

To evaluate the feasibility of mapping and ablation of AAFL using a novel high-density 3D-EAM system.

Methods

We analyzed prospectively collected data on 673 consecutive patients who underwent high-density mapping and ablation between November 2024 and August 2025 with an expandable 9-mm lattice-tip, multipolar, dual-energy catheter. We included patients with AAFL in which activation mapping covered >80% of tachycardia cycle length. Ablation targeted the critical isthmus identified on the activation map. The primary efficacy outcome was defined as termination of the tachycardia at the initial ablation site or within the surrounding area. Secondary efficacy outcomes were procedural success and AFL recurrence during follow-up.

Results

A total of 65 patients (mean age 71.3±10.3 years, 36.9% female) were included. Most patients had undergone ≥1 previous atrial fibrillation ablation procedures (87.7%). The median AAFL cycle length was 257ms (234–290). Left-sided AAFL was identified in 86.2% of patients. Procedural success was achieved in all procedures (100%), with primary efficacy outcome reached in 79.4% of patients (34.9% at the first lesion, 44.4% within the surrounding area). During a median follow-up of 69 (48.8–116) days, atrial flutter recurrence occurred in 15% of patients, yielding estimated event-free survival rates of 88.3%, 85.1%, and 79.7% at 1, 3, and 6 months, respectively.

Conclusion

The study results demonstrate the feasibility of this novel system to successfully map and ablate AAFLs.AAFL ablation dataTermination of right-sided AAFL

Zitieren

APA

Chiarazzo, E., Marino, M., Fazia, V. M. L., Gianni, C., Mohanty, S., Stifano, G., Bode, W., Awad, K., Burkhardt, D., Gallinghouse, J., Horton, R. P., Al-Ahmad, A., Biase, L. D., & Natale, A. (2026). Feasibility of mapping and ablation of atypical atrial flutter using a lattice-tip catheter toggling between radiofrequency and pulsed field energy. Europace, 28(Supplement_1). https://doi.org/10.1093/europace/euag105.577

Vancouver

Chiarazzo E, Marino M, Fazia VML, Gianni C, Mohanty S, Stifano G, et al. Feasibility of mapping and ablation of atypical atrial flutter using a lattice-tip catheter toggling between radiofrequency and pulsed field energy. Europace. 2026;28(Supplement_1). doi:10.1093/europace/euag105.577

BibTeX
@article{Chiarazzo2026,
  author = {Chiarazzo, E and Marino, M and Fazia, V M La and Gianni, C and Mohanty, S and Stifano, G and Bode, W and Awad, K and Burkhardt, D and Gallinghouse, J and Horton, R P and Al-Ahmad, A and Biase, L Di and Natale, A},
  title = {Feasibility of mapping and ablation of atypical atrial flutter using a lattice-tip catheter toggling between radiofrequency and pulsed field energy},
  journal = {Europace},
  year = {2026},
  volume = {28},
  number = {Supplement_1},
  doi = {10.1093/europace/euag105.577}
}