Incidence and predictors of AF recurrence during long-term follow-up of patients after PF ablation for atrial fibrillation
Europace · 30.03.2026 · 28 (4)
DOI: 10.1093/europace/euag057 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, online erschienen am 23.03.2026. Verfasst von Anna-Sophie Eberl und 10 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Medicine, Medical University of Graz, Austria. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pulmonary Veins, Catheter Ablation. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Aims
Pulsed field ablation (PFA) is an established technology for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). However, data on long-term outcome remain scarce. With this work, we aim to contribute valuable long-term data on catheter ablation with PFA. Methods and results We conducted a retrospective analysis of our single-centre data of 339 patients (63% paroxysmal AF, 37% persistent AF), as well as of 55 redo procedures in patients, who underwent first PVI with a pentaspline PFA catheter. During the median follow-up (FUP) of 752 (391–1486) days, 34% patients (n = 116) experienced arrhythmia recurrence after a blanking period of 90 days, with a median time to recurrence of 218 (90–1161) days. Multivariate analysis showed electrical cardioversion at the end [HR 1.97 (95% CI 1.17–3.33), P = 0.011] and AF at the beginning of the procedure [HR 1.73 (95% CI 1.04–2.88), P = 0.034] being independently associated with a higher risk of arrhythmia recurrence. Additional anterior flower applications were protective in the univariate (P = 0.025) analysis. Atrial tachycardia (AT) was present in 16, 37, 0, and 0% after the first, second, third, and fourth procedure, respectively. In 55 analysed redo procedures, 104/221 veins (47%) were reconnected (0/1/2/3/4 reconnected veins: 9%/31%/27.3%/27.3%/5.4%). Analysis of multiple procedure outcome estimates improved long-term arrhythmia-free survival, with an overall success rate of 86% after ≥2 procedures.
Conclusion
PV reconnections are frequent in patients presenting for repeat ablations, especially at the anterior PV aspect. A multiple procedure approach estimates arrhythmia-free survival in 86% of patients. Procedures with additional anterior lesions at the right pulmonary veins (RPVs) could be protective for recurrences.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology, Department of Medicine, Medical University of Graz, Austria.
- Division of Paediatric Cardiology, Department of Paediatrics & Adolescence Medicine, Medical University of Graz, Austria.
ORCID-Profile: Anna-Sophie Eberl, Martin Manninger, Ursula Rohrer, Laura Stix, Stefan Kurath-Koller, Katharina Gölly, Martin Benedikt, Andreas Zirlik, Daniel Scherr
Zitieren
APA
Eberl, A. S., Manninger, M., Rohrer, U., Stix, L., Kurath-Koller, S., Gölly, K., Benedikt, M., Bisping, E., Lercher, P., Zirlik, A., & Scherr, D. (2026). Incidence and predictors of AF recurrence during long-term follow-up of patients after PF ablation for atrial fibrillation. Europace, 28(4). https://doi.org/10.1093/europace/euag057
Vancouver
Eberl AS, Manninger M, Rohrer U, Stix L, Kurath-Koller S, Gölly K, et al. Incidence and predictors of AF recurrence during long-term follow-up of patients after PF ablation for atrial fibrillation. Europace. 2026;28(4). doi:10.1093/europace/euag057
BibTeX
@article{Eberl2026,
author = {Eberl, Anna-Sophie and Manninger, Martin and Rohrer, Ursula and Stix, Laura and Kurath-Koller, Stefan and Gölly, Katharina and Benedikt, Martin and Bisping, Egbert and Lercher, Peter and Zirlik, Andreas and Scherr, Daniel},
title = {Incidence and predictors of AF recurrence during long-term follow-up of patients after PF ablation for atrial fibrillation},
journal = {Europace},
year = {2026},
volume = {28},
number = {4},
doi = {10.1093/europace/euag057}
}
EUVIMED