EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Discordance between left atrial pressure and risk scores in assessment of heart failure with preserved ejection fraction in patients with atrial fibrillation undergoing catheter ablation

Monika Gawałko iD, Zarina Habibi iD, Dominique V M Verhaert iD, Madelon Engels iD, Jerremy Weerts iD, Bouke Adriaans iD, Sevasti-Maria Chaldoupi iD, Rachel M A Ter Bekke iD, Dennis W Den Uijl iD, Justin G L M Luermans iD, Vanessa P M Van Empel iD, Ulrich Schotten iD und 2 weitere

Europace · 2025

DOI: 10.1093/europace/euaf245 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Europace, 2025. Verfasst von Monika Gawałko und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht (CARIM), P. Debyelaan 25, Maastricht,…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Heart Failure, Stroke Volume. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Identifying risk or probability of heart failure with preserved ejection fraction (HFpEF) in patients with atrial fibrillation (AF) is challenging. This study aimed to assess the prevalence and factors associated with elevated left atrial pressure (LAP) in AF patients undergoing catheter ablation and to evaluate the concordance between elevated LAP and HFpEF risk scores. Methods and results This study included 336 symptomatic AF patients (median age 65 years, 41% female) undergoing catheter ablation. Elevated LAP was defined as a mean LAP ≥ 15 mmHg. High HFpEF probability was defined by H2FPEF ≥ 6 and/or HFA-PEFF ≥ 5. Elevated LAP was present in 37% (n = 125) of patients, and factors associated with elevated LAP included higher body mass index (BMI; OR 1.21, 95% CI: 1.11–1.31) and lower LA reservoir strain (OR 0.97, 95% CI: 0.94–0.99). General anaesthesia and non-sinus rhythm were linked to higher LAP but not independently; AF type showed no effect. Among 204 eligible patients, 36% had a high HFpEF probability. Over 12 months, AF recurrence (26% vs. 24%, P = 0.775) and repeat ablations (11% vs. 7.2%, P = 0.230) were similar regardless of LAP status, but severe adverse events (death, life-threatening situations, hospitalizations, or persistent disability) were more common in those with elevated LAP (6.7% vs. 1.7%, P = 0.044).

Conclusion

Over one-third of catheter ablation patients had elevated LAP. Poor agreement between elevated LAP and HFpEF risk scores suggests that using these risk scores may not be advisable in AF population.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationHeart FailureStroke VolumeAtrial PressureAtrial Function, LeftVentricular Function, LeftHumansFemaleMaleAgedRisk AssessmentMiddle AgedRisk FactorsRecurrenceTreatment OutcomePrevalenceRetrospective Studies

Stichwörter der Autor:innen

Atrial fibrillationCatheter ablationHeart failure with preserved ejection fraction

Autor:innen und Institutionen

  • Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht (CARIM), P. Debyelaan 25, Maastricht, HX 6229, The Netherlands.
  • Department of Cardiology, Medical University of Warsaw, Banacha 1a, Warsaw 02-097, Poland.
  • Department of Cardiology, Radboud University Medical Center and Radboud Institute for Health Sciences, Geert Grooteplein Zuid 10, Nijmegen, GA 6525, The Netherlands.
  • Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Nørregade 10, Copenhagen 1165, Denmark.

ORCID-Profile: Monika Gawałko, Zarina Habibi, Dominique V M Verhaert, Madelon Engels, Jerremy Weerts, Bouke Adriaans, Sevasti-Maria Chaldoupi, Rachel M A Ter Bekke, Dennis W Den Uijl, Justin G L M Luermans, Vanessa P M Van Empel, Ulrich Schotten, Kevin Vernooy, Dominik Linz

Zitieren

APA

Gawałko, M., Habibi, Z., Verhaert, D. V. M., Engels, M., Weerts, J., Adriaans, B., Chaldoupi, S. M., Ter Bekke, R. M. A., Den Uijl, D. W., Luermans, J. G. L. M., Van Empel, V. P. M., Schotten, U., Vernooy, K., & Linz, D. (2025). Discordance between left atrial pressure and risk scores in assessment of heart failure with preserved ejection fraction in patients with atrial fibrillation undergoing catheter ablation. Europace. https://doi.org/10.1093/europace/euaf245

Vancouver

Gawałko M, Habibi Z, Verhaert DVM, Engels M, Weerts J, Adriaans B, et al. Discordance between left atrial pressure and risk scores in assessment of heart failure with preserved ejection fraction in patients with atrial fibrillation undergoing catheter ablation. Europace. 2025. doi:10.1093/europace/euaf245

BibTeX
@article{Gawako2025,
  author = {Gawałko, Monika and Habibi, Zarina and Verhaert, Dominique V M and Engels, Madelon and Weerts, Jerremy and Adriaans, Bouke and Chaldoupi, Sevasti-Maria and Ter Bekke, Rachel M A and Den Uijl, Dennis W and Luermans, Justin G L M and Van Empel, Vanessa P M and Schotten, Ulrich and Vernooy, Kevin and Linz, Dominik},
  title = {Discordance between left atrial pressure and risk scores in assessment of heart failure with preserved ejection fraction in patients with atrial fibrillation undergoing catheter ablation},
  journal = {Europace},
  year = {2025},
  doi = {10.1093/europace/euaf245}
}
Kostenlos starten →