EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudieOpen Access · CC BY 4.0

Conduction system pacing versus biventricular pacing for cardiac resynchronization: the CSP-SYNC randomized single center study

David Žižek iD, Tadej Žlahtič iD, Miha Mrak iD, Maja Ivanovski iD, Jernej Štublar, Dinko Zavrl Džananović iD, Jakob Peterlin iD, Marta Cvijić iD, Anja Zupan Mežnar iD

Europace · 23.08.2025

DOI: 10.1093/europace/euaf192 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Europace, online erschienen am 23.08.2025. Verfasst von David Žižek und 8 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Department, University Medical Centre Ljubljana, Zaloška 2, 1000 Ljubljana, Slovenia. Hauptthemen laut MEDLINE: Cardiac Resynchronization Therapy, Heart Failure, Bundle of His. Die Arbeit wurde bisher 28-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University Medical Centre Ljubljana, Slovenian Research and Innovation Agency.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

There are limited prospective randomized studies comparing left bundle branch area pacing (LBBAP) and biventricular (BiV) pacing for cardiac resynchronization therapy (CRT).

Aim

The study tested whether LBBAP is noninferior to BiV pacing in patients with Class I indication for CRT.

Methods

The CSP-SYNC study is an investigator-initiated, randomized, single-center study. Sixty-two patients were randomized 1:1 to LBBAP or BiV. The primary study endpoint was change in left ventricular ejection fraction (LVEF) at 6 months. Secondary endpoints included changes in echo and clinical parameters after 6 months and 12 months.

Results

Thirty-one patients were randomized to each arm. Most patients were males (71%), and 32 % had ischemic cardiomyopathy. At 6 months, similar improvement of LVEF was observed in the LBBAP group compared to the BiV group (14.0% (95% CI: 11.2-16.8) in LBBAP vs. 8.5% (95% CI: 5.6-11.2) in BiV) with mean intergroup difference of 5.6% (95% CI: 1.6-9.5; P<0.001 for noninferiority). Both groups showed comparable decrease in LVESV (-64 ml (95% CI: -78 to -50) vs -40 ml (95% CI: -54 to -25) respectively, mean difference -24 ml (CI 95%: -44 to -4); P<0.001 for noninferiority), changes in 6-minute walk test (P<0.001 for noninferiority) and NYHA class (P=0.011 for noninferiority). Temporal trends of LV remodelling and heart failure hospitalization rates were also comparable.

Conclusions

In patients with a Class I indication for CRT, LBBAP was noninferior to BiV pacing in improving LVEF and provided similar structural and electrical remodelling.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiac Resynchronization TherapyHeart FailureBundle of HisHumansMaleFemaleAgedStroke VolumeVentricular Function, LeftMiddle AgedTreatment OutcomeProspective StudiesTime FactorsRecovery of FunctionVentricular Remodeling

Stichwörter der Autor:innen

Biventricular pacingCardiac resynchronization therapyConduction system pacingLeft bundle branch area pacingLeft bundle branch block

Autor:innen und Institutionen

  • Cardiology Department, University Medical Centre Ljubljana, Zaloška 2, 1000 Ljubljana, Slovenia.
  • Faculty of Medicine, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia.

ORCID-Profile: David Žižek, Tadej Žlahtič, Miha Mrak, Maja Ivanovski, Dinko Zavrl Džananović, Jakob Peterlin, Marta Cvijić, Anja Zupan Mežnar

Förderung

  • University Medical Centre Ljubljana
  • Slovenian Research and Innovation Agency

Zitieren

APA

Žižek, D., Žlahtič, T., Mrak, M., Ivanovski, M., Štublar, J., Džananović, D. Z., Peterlin, J., Cvijić, M., & Zupan Mežnar, A. (2025). Conduction system pacing versus biventricular pacing for cardiac resynchronization: the CSP-SYNC randomized single center study. Europace. https://doi.org/10.1093/europace/euaf192

Vancouver

Žižek D, Žlahtič T, Mrak M, Ivanovski M, Štublar J, Džananović DZ, et al. Conduction system pacing versus biventricular pacing for cardiac resynchronization: the CSP-SYNC randomized single center study. Europace. 2025. doi:10.1093/europace/euaf192

BibTeX
@article{iek2025,
  author = {Žižek, David and Žlahtič, Tadej and Mrak, Miha and Ivanovski, Maja and Štublar, Jernej and Džananović, Dinko Zavrl and Peterlin, Jakob and Cvijić, Marta and Zupan Mežnar, Anja},
  title = {Conduction system pacing versus biventricular pacing for cardiac resynchronization: the CSP-SYNC randomized single center study},
  journal = {Europace},
  year = {2025},
  doi = {10.1093/europace/euaf192}
}
Kostenlos starten →