Excellent interobserver agreement and steep learning curve for target volume delineation for stereotactic arrhythmia radioablation using a commercial software
Europace · 2025
DOI: 10.1093/europace/euaf122 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, 2025. Verfasst von Robert Rademaker und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Leiden University Medical Center, P.O. Box 9600, Leiden 2300 RC, The Netherlands. Hauptthemen laut MEDLINE: Learning Curve, Radiosurgery, Software, Tachycardia, Ventricular. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union's Horizon-2020 research and innovation programme.
Abstract (Originalsprache)
Aims
Stereotactic arrhythmia radioablation (STAR) has emerged as bail-out treatment for ventricular tachycardia (VT). Accurate, reproducible, and easy-to-use data transfer from electroanatomical mapping (EAM) systems to radiotherapy planning CT is desirable. We aim to evaluate interobserver variability, ease of use, and learning curve for EAM based target volume (CardTV-EPinv) creation and transfer using available software packages. Methods and results In patients considered for STAR, CardTV-EPinv were created using ADAS and Slicer3D for workflow comparison. Four CardTV-EPinv (clinically targeted volume and three mock targets) were created by an experienced operator and a 2nd-year medical student, based on endocardial EAM tags indicating VT substrate location. CardTV-EPinv sizes, Hausdorff distances (HDs), and workflow duration were measured to assess interobserver variability and learning curve. Agreement between CardTV-EPinv was high using ADAS and Slicer3D workflows (HD 3.64 mm [2.7–4.5]). ADAS workflow was faster and more robust (ADAS 26 min [24–29] vs. Slicer3D 65 min [61–70], P < 0.001; system crashes: ADAS 0 vs. Slicer3D 7). In 20 patients (80% non-ischaemic cardiomyopathy, LVEF 35 ± 14%), 80 CardTV-EPinv were created using ADAS. CardTV-EPinv size was similar for both observers (11.8 mL [10.1–13.7] vs. 10.7 mL [9.6–11.8], P = 0.17), with high interobserver agreement (HD 1.68 mm [1.45–1.96]; 95th percentile HD < 4.8 mm [3.5–5.7]). Linear regression showed a steep learning curve for the student (P = 0.01).
Conclusion
CardTV-EPinv creation showed excellent interobserver agreement and was faster and more robust using ADAS than 3D slicer. The steep learning curve appears clinically relevant given the limited use of STAR even in high-volume VT ablation centres.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Leiden University Medical Center, P.O. Box 9600, Leiden 2300 RC, The Netherlands.
- Willem Einthoven Center of Arrhythmia Research and Management, Leiden, The Netherlands, Aarhus, Denmark.
- Department of Radiation Oncology, Leiden University Medical Center, Leiden, The Netherlands.
- Department of Cardiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic.
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland.
- Department of Cardiology, Maastricht University Medical Center+ (MUMC+), Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands.
ORCID-Profile: Robert Rademaker, Sharif Omara, Frank J W M Dankers, Marek Sramko, J Solana Munoz, Yesim S Kaya, Rachel M A Ter Bekke, Luis Schiappacasse, Cheryl Teres, Etienne Pruvot, Coen R N Rasch, Katja Zeppenfeld
Förderung
- European Union's Horizon-2020 research and innovation programme
Zitieren
APA
Rademaker, R., Cirkel, S., Omara, S., Dankers, F. J. W. M., Sramko, M., Solana Munoz, J., Kaya, Y. S., Ter Bekke, R. M. A., Schiappacasse, L., Teres, C., Verhoeven, K., Pruvot, E., Rasch, C. R. N., & Zeppenfeld, K. (2025). Excellent interobserver agreement and steep learning curve for target volume delineation for stereotactic arrhythmia radioablation using a commercial software. Europace. https://doi.org/10.1093/europace/euaf122
Vancouver
Rademaker R, Cirkel S, Omara S, Dankers FJWM, Sramko M, Solana Munoz J, et al. Excellent interobserver agreement and steep learning curve for target volume delineation for stereotactic arrhythmia radioablation using a commercial software. Europace. 2025. doi:10.1093/europace/euaf122
BibTeX
@article{Rademaker2025,
author = {Rademaker, Robert and Cirkel, Simon and Omara, Sharif and Dankers, Frank J W M and Sramko, Marek and Solana Munoz, J and Kaya, Yesim S and Ter Bekke, Rachel M A and Schiappacasse, Luis and Teres, Cheryl and Verhoeven, Karolien and Pruvot, Etienne and Rasch, Coen R N and Zeppenfeld, Katja},
title = {Excellent interobserver agreement and steep learning curve for target volume delineation for stereotactic arrhythmia radioablation using a commercial software},
journal = {Europace},
year = {2025},
doi = {10.1093/europace/euaf122}
}
EUVIMED