A comparative analysis of conduction system pacing and biventricular pacing in patients undergoing atrioventricular node ablation: a systematic review and meta-analysis
Europace · 2025
DOI: 10.1093/europace/euaf106 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Europace, 2025. Verfasst von Akash Mavilakandy und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester LE3 9QP, UK. Hauptthemen laut MEDLINE: Atrioventricular Node, Catheter Ablation, Cardiac Resynchronization Therapy, Atrial Fibrillation. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Aims
Atrioventricular node ablation (AVNA) with permanent pacemaker implantation is an established rate-control treatment approach for patients with AF with uncontrolled ventricular rates. Conduction system pacing (CSP) utilizing His bundle pacing (HBP) or left bundle branch area pacing (LBBAP) has advanced as a treatment alternative to standard right ventricular pacing in addition to biventricular pacing (BVP). This systematic review and meta-analysis aim to provide a comprehensive summary and evaluation of clinical outcomes in the literature for CSP in comparison to BVP in conjunction with AVNA. Methods and results This study protocol was registered in the PROSPERO registry (CRD42024510974), and the review was conducted as per the PRISMA guidelines. Databases were searched for relevant studies from inception till 11 January 2024. Results were synthesized using a random effects meta-analysis. From a total of 259 references identified, 122 full texts were assessed, and 25 studies were included in the systematic review. Of these included studies, five were used for comparative meta-analysis. A total of 1652 (HBP 1069 and LBBAP 644) and 369 patients received CSP and BVP implantation with AVNA, respectively. Conduction system pacing resulted in a narrower QRS duration (QRSd) with a change of −35.8 ms (95% CI −61.8 to −9.72; P < 0.05; I2 = 96.3%) vs. BVP. Conduction system pacing also resulted in better symptomatic improvement in from of NYHA reduction (MD −0.53, 95% CI −1.01 to −0.04, I2 = 62.1; P = 0.03). For left ventricular ejection fraction, a non-significant weighted mean increases of 3.36% (95% CI −0.75–7.47%; P = 0.11, I2 = 68.5%) was observed following CSP implantation in comparison to BVP. Conduction system pacing showed no significant differences in procedural and fluoroscopy times and had comparable periprocedural complications. His bundle pacing demonstrated a non-significant reduction in the events of acute threshold elevation in comparison to BVP (Log odds ratio −0.69, 95% CI −2.05–0.66, I2 = 0.00; P = 0.32).
Conclusion
Conduction system pacing with AVNA is a safe and feasible treatment option for symptomatic (AF) patients undergoing a pace and ablate strategy, offering an alternative to BVP. Overall, CSP results in a narrower QRS duration while providing comparable clinical and echocardiographic outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester LE3 9QP, UK.
- Department of Cardiovascular Sciences, University of Leicester, Leicester LE3 9QP, UK.
- Cardiology Department, Faculty of Medicine, Al-Azhar University, New Damietta, Egypt.
- Department of Cardiology, Amrita Institute of Medical Sciences and Research, Kochi, KL 682041, India.
- National Institute for Health Research Leicester Biomedical Research Centre, Leicester LE3 9QP, UK.
- Cardiology Department, Ain Shams University, Cairo, Egypt.
ORCID-Profile: Ahmed M Abdelrazik, Khaled Abouelmagd, Ivelin Koev, Ravi Chotalia, Sachin Sudhakaran, Abdulmalik Idris Koya, Hany Eldeeb, Hisham Ahamed, Harshil Dhutia, Riyaz Somani, G Andre Ng, Mokhtar Ibrahim
Zitieren
APA
Mavilakandy, A., Abdelrazik, A. M., Abouelmagd, K., Koev, I., Chotalia, R., Sudhakaran, S., Koya, A. I., Antoun, I., Eldeeb, H., Ahamed, H., Dhutia, H., Somani, R., Ng, G. A., & Ibrahim, M. (2025). A comparative analysis of conduction system pacing and biventricular pacing in patients undergoing atrioventricular node ablation: a systematic review and meta-analysis. Europace. https://doi.org/10.1093/europace/euaf106
Vancouver
Mavilakandy A, Abdelrazik AM, Abouelmagd K, Koev I, Chotalia R, Sudhakaran S, et al. A comparative analysis of conduction system pacing and biventricular pacing in patients undergoing atrioventricular node ablation: a systematic review and meta-analysis. Europace. 2025. doi:10.1093/europace/euaf106
BibTeX
@article{Mavilakandy2025,
author = {Mavilakandy, Akash and Abdelrazik, Ahmed M and Abouelmagd, Khaled and Koev, Ivelin and Chotalia, Ravi and Sudhakaran, Sachin and Koya, Abdulmalik Idris and Antoun, Ibrahim and Eldeeb, Hany and Ahamed, Hisham and Dhutia, Harshil and Somani, Riyaz and Ng, G Andre and Ibrahim, Mokhtar},
title = {A comparative analysis of conduction system pacing and biventricular pacing in patients undergoing atrioventricular node ablation: a systematic review and meta-analysis},
journal = {Europace},
year = {2025},
doi = {10.1093/europace/euaf106}
}
EUVIMED