Ablation characteristics associated with steam pops in ablation index-guided radiofrequency ablation of atrial fibrillation
Europace · 28.03.2025 · 27 (4)
DOI: 10.1093/europace/euaf084 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, online erschienen am 08.04.2025. Verfasst von Xue-Si Wang und 30 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, No. 2, Anzhen Road, Chaoyang District, Beijing 100029, China. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pulmonary Veins, Catheter Ablation, Steam. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Natural Science Foundation of China, ZHONGNANSHAN MEDICAL FOUNDATION OF GUANGDONG PROVINCE, Beijing Xinlian Zhicheng Cardiovascular Health Public Welfare Foundation.
Abstract (Originalsprache)
Aims
Steam pops present a significant concern during radiofrequency (RF) ablation of atrial fibrillation (AF). It is crucial to analyse the incidence and ablation characteristics associated with steam pops. This study aims to investigate the occurrence and potential predictors of steam pops. Methods and results This study included 3263 patients with AF who underwent RF ablation. Patients with paroxysmal AF received bilateral circumferential pulmonary vein (PV) ablation, while those with persistent AF underwent additional linear ablation. The ablation parameters at the sites of steam pops were compared to those at adjacent anatomical locations. A total of 81 steam pops (2.5%) with one pericardial tamponade were recorded. Steam pops were observed at liner ablation sites: 6 (0.4%) at the mitral isthmus, 16 (0.9%) at the tricuspid isthmus (CTI), and 7 (0.5%) along the roofline. The most common sites of steam pops were the anterior edge of the left superior PV and the inferior vena cava side of the CTI. The impedance drop was significantly higher (18.2 ± 9.5 Ω vs. 13.5 ± 4.8 Ω, P < 0.001) at steam pop sites. The optimal cut-off points of impedance drop for predicting steam pops were > 9.5 Ω within the first 3 s, > 10.5 Ω within the first 5 s, > 13.5 Ω within the first 10 s, and > 18.5 Ω in the whole ablation, respectively.
Conclusion
The incidence of steam pops during ablation of AF is infrequent. Impedance drop is the only ablation parameter that could predict the occurrence of steam pops.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, No. 2, Anzhen Road, Chaoyang District, Beijing 100029, China.
- Department of Cardiology, Zhangjiakou First Hospital, Qiaoxi District, Zhangjiakou 075000, China.
- Department of Cardiology, The Third People's Hospital of Datong, Pingcheng District, Datong 037000, China.
ORCID-Profile: Xue-Si Wang, Ze-Yang Wu, De-Yong Long, Cai-Hua Sang, Xin Zhao, Nian Liu, Song-Nan Li, Xiao-Xia Liu, Song Zuo, Ming-Yang Gao, Li Feng, Wen-He Lv, Yu-Kun Li, Xiao-Ying Liu, Xin-Ru Li, Jian-Zeng Dong, Chang-Sheng Ma, Ri-Bo Tang
Förderung
- National Natural Science Foundation of China
- ZHONGNANSHAN MEDICAL FOUNDATION OF GUANGDONG PROVINCE
- Beijing Xinlian Zhicheng Cardiovascular Health Public Welfare Foundation
Zitieren
APA
Wang, X. S., Wu, Z. Y., Wu, Q., Long, D. Y., Sang, C. H., Jiang, C. X., Wang, W., Zhao, X., Li, C. Y., Yu, R. H., Liu, N., Li, S. N., Liu, X. X., Guo, X. Y., Zuo, S., Li, M. M., Liu, T., Dai, W. L., Gao, M. Y., …, & Tang, R. B. (2025). Ablation characteristics associated with steam pops in ablation index-guided radiofrequency ablation of atrial fibrillation. Europace, 27(4). https://doi.org/10.1093/europace/euaf084
Vancouver
Wang XS, Wu ZY, Wu Q, Long DY, Sang CH, Jiang CX, et al. Ablation characteristics associated with steam pops in ablation index-guided radiofrequency ablation of atrial fibrillation. Europace. 2025;27(4). doi:10.1093/europace/euaf084
BibTeX
@article{Wang2025,
author = {Wang, Xue-Si and Wu, Ze-Yang and Wu, Qi and Long, De-Yong and Sang, Cai-Hua and Jiang, Chen-Xi and Wang, Wei and Zhao, Xin and Li, Chang-Yi and Yu, Rong-Hui and Liu, Nian and Li, Song-Nan and Liu, Xiao-Xia and Guo, Xue-Yuan and Zuo, Song and Li, Meng-Meng and Liu, Tong and Dai, Wen-Li and Gao, Ming-Yang and Jia, Chang-Qi and Ning, Man and Feng, Li and Lv, Wen-He and Li, Yu-Kun and Liu, Xiao-Ying and Du, Zhuo-Hang and Li, Jia-Lin and Li, Xin-Ru and Dong, Jian-Zeng and Ma, Chang-Sheng and Tang, Ri-Bo},
title = {Ablation characteristics associated with steam pops in ablation index-guided radiofrequency ablation of atrial fibrillation},
journal = {Europace},
year = {2025},
volume = {27},
number = {4},
doi = {10.1093/europace/euaf084}
}
EUVIMED