Improved outcomes with leadless vs. single-chamber transvenous pacemaker in haemodialysis patients
Europace · 01.11.2024 · 26 (11)
DOI: 10.1093/europace/euae257 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Europace, online erschienen am 01.10.2024. Verfasst von Alexandre Panico und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nephrology, Centre Hospitalier Régional Universitaire de Nancy, Rue du Morvan, 54500 Vandoeuvre-Les-Nancy, France. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Renal Dialysis. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Agence de la biomédecine, Agence Régionale de Santé.
Abstract (Originalsprache)
Aims
Cardiac conduction disorders are common in haemodialysis patients, with a relatively high rate of pacemaker implantations. Pacemaker-related complications, especially lead infections and central venous stenosis, pose significant challenges in this population. This study aims to compare single-chamber leadless pacemaker to single-chamber transvenous pacemakers in terms of survival and related complications in haemodialysis patients. Methods and results This retrospective study included adult haemodialysis patients who received a first single-chamber transvenous or leadless pacemaker between January 2017 and December 2020. Data were obtained from the French national REIN registry matched to the national health databases (Système National des Données de Santé). Propensity score matching was used to balance baseline characteristics. Survival and complications were compared between groups by Cox regression and by competitive risk models, respectively. One hundred and seventy-eight patients were included after propensity score matching, with 89 patients in each group. The median follow-up time was 24 (range 7–37) months. Leadless pacemakers were associated with significantly lower all-cause mortality rates compared to transvenous pacemakers [hazard ratio (HR) = 0.68, 95% confidence interval (CI) (0.47–0.99)]. Device-related infections are significantly lower with leadless pacemakers throughout the follow-up period (HR 0.43, 95% CI 0.21–0.86). Leadless pacemaker recipients also required fewer vascular access interventions [odds ratio 0.53, 95% CI (0.33–0.68)] on arteriovenous fistula.
Conclusion
With the limitations of its observational design, this study suggests that leadless pacemakers are associated with a lower rate of complications and better survival as compared with transvenous VVI pacemakers in haemodialysis patients, supporting to consider their preferential use in this population.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Nephrology, Centre Hospitalier Régional Universitaire de Nancy, Rue du Morvan, 54500 Vandoeuvre-Les-Nancy, France.
- Centre Hospitalier Régional Universitaire de Nancy, Inserm, Université de Lorraine, Clinical Investigation Centre-Clinical Epidemiology, Nancy, France.
- Université de Lorraine, Inserm, UMR INSPIIRE, 9 avenue de la Forêt de Haye, 54500 Vandoeuvre-Les-Nancy, France.
- Department of Cardiology, APHP, Hôpital Européen Georges Pompidou, Paris, France.
- REIN Registry, Agence de la biomédecine, Saint Denis La Plaine, France.
- Department of Nephrology, Centre Hospitalier Universitaire de Poitiers, Poitiers, France.
ORCID-Profile: Alexandre Panico, Adrien Flahault, Francis Guillemin, Cécile Couchoud, Eloi Marijon, Hélène Lazareth
Förderung
- Agence de la biomédecine
- Agence Régionale de Santé
Zitieren
APA
Panico, A., Flahault, A., Guillemin, F., Varlet, E., Couchoud, C., Bauwens, M., Marijon, E., Roueff, S., & Lazareth, H. (2024). Improved outcomes with leadless vs. single-chamber transvenous pacemaker in haemodialysis patients. Europace, 26(11). https://doi.org/10.1093/europace/euae257
Vancouver
Panico A, Flahault A, Guillemin F, Varlet E, Couchoud C, Bauwens M, et al. Improved outcomes with leadless vs. single-chamber transvenous pacemaker in haemodialysis patients. Europace. 2024;26(11). doi:10.1093/europace/euae257
BibTeX
@article{Panico2024,
author = {Panico, Alexandre and Flahault, Adrien and Guillemin, Francis and Varlet, Emilie and Couchoud, Cécile and Bauwens, Marc and Marijon, Eloi and Roueff, Stéphane and Lazareth, Hélène},
title = {Improved outcomes with leadless vs. single-chamber transvenous pacemaker in haemodialysis patients},
journal = {Europace},
year = {2024},
volume = {26},
number = {11},
doi = {10.1093/europace/euae257}
}
EUVIMED