Multizentrische Studie in der Zeitschrift Europace, 2024. Verfasst von Diana M Frodi und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Copenhagen University Hospital-Rigshospitalet, Inge Lehmanns Vej 7, 2100 Copenhagen, Denmark. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Sleep, Electric Countershock. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Physical activity has shown association with ventricular arrhythmia, however, the role of specific behavioral patterns over a 24 h cycle remains unknown. Therefore, we aimed to explore associations between physical behavior and appropriate implantable cardioverter defibrillator (ICD) therapy. Methods and results We included patients with an ICD at two European sites, who wore wrist-based accelerometers capturing 24 h movement and sleep behaviours for 28 days. Behavioural measures included activity volume, duration and intensity, sleep duration, and efficiency. Participants were followed for 12 months for the outcome of appropriate ICD therapy. Cox proportional hazard models with restricted cubic splines were used for the analysis. Lastly, the predictive capacity was tested. A total of 253 ICD patients were included (mean age 63.5 (±10.2), 48 (19.0%) female). During follow-up, 40 participants (15.8%) received appropriate ICD therapy; 32 anti-tachycardia pacing (ATP) only (12.6%), 5 shock only (2.0%), and 3 combined ATP and shock (1.2%). In the adjusted model, high inactive duration (HR 1.40 (95% 1.10–1.78)), peak walking cadence (HR 1.07 (95% 1.03–1.12)), and total sleep duration (HR 1.50 (1.02–2.22)) were associated with the outcome. The dose–response relationship was U-shaped for inactive duration with a cut-off at 16 h, and linear for peak cadence and sleep. The prediction model reached an area under the receiver operating characteristic curve of 0.70 ± 0.03, with highest accuracy in the first months.

Conclusion

Wearable-derived 24 h movement and sleep behaviours collected over 28 days were associated with later appropriate ICD therapy risk. Testing of the predictive value of digital biomarkers for enhanced risk stratification of ventricular arrhythmia warrants larger prospective studies. Clinical Trial Registration National Trial Registration (NL9218, http://onderzoekmetmensen.nl/).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantableSleepElectric CountershockHumansFemaleMaleMiddle AgedProspective StudiesAgedActigraphyFitness TrackersRisk FactorsTreatment OutcomeTime FactorsPredictive Value of TestsTachycardia, VentricularExerciseWearable Electronic DevicesEurope

Stichwörter der Autor:innen

Behavioural patternsImplantable cardioverter defibrillatorPredictionVentricular arrhythmiaWearable activity trackerWearable technology

Autor:innen und Institutionen

  • Department of Cardiology, Copenhagen University Hospital-Rigshospitalet, Inge Lehmanns Vej 7, 2100 Copenhagen, Denmark.
  • Department of Clinical and Experimental Cardiology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.
  • Activinsights Ltd., Kimbolton, UK.
  • College of Life and Environmental Sciences, University of Exeter, Exeter, UK.
  • Netherlands Heart Institute, Utrecht, The Netherlands.
  • Department of Computer Science, University of Copenhagen, Copenhagen, Denmark.

ORCID-Profile: Diana M Frodi, Maarten Z H Kolk, Søren Z Diederichsen, Joss Langford, Reinoud E Knops, Hanno L Tan, Tariq O Andersen, Peter Karl Jacobsen, Niels Risum, Fleur V Y Tjong, Jesper Hastrup Svendsen

Förderung

  • European Union

Zitieren

APA

Frodi, D. M., Kolk, M. Z. H., Diederichsen, S. Z., Langford, J., Knops, R. E., Tan, H. L., Andersen, T. O., Jacobsen, P. K., Risum, N., Tjong, F. V. Y., & Svendsen, J. H. (2024). Relationship between activity and sleep, as measured through a wearable accelerometer, and appropriate cardioverter defibrillator interventions: a prospective SafeHeart substudy. Europace. https://doi.org/10.1093/europace/euae241

Vancouver

Frodi DM, Kolk MZH, Diederichsen SZ, Langford J, Knops RE, Tan HL, et al. Relationship between activity and sleep, as measured through a wearable accelerometer, and appropriate cardioverter defibrillator interventions: a prospective SafeHeart substudy. Europace. 2024. doi:10.1093/europace/euae241

BibTeX
@article{Frodi2024,
  author = {Frodi, Diana M and Kolk, Maarten Z H and Diederichsen, Søren Z and Langford, Joss and Knops, Reinoud E and Tan, Hanno L and Andersen, Tariq O and Jacobsen, Peter Karl and Risum, Niels and Tjong, Fleur V Y and Svendsen, Jesper Hastrup},
  title = {Relationship between activity and sleep, as measured through a wearable accelerometer, and appropriate cardioverter defibrillator interventions: a prospective SafeHeart substudy},
  journal = {Europace},
  year = {2024},
  doi = {10.1093/europace/euae241}
}
Kostenlos starten →