Closed loop stimulation reduces the incidence of atrial high-rate episodes compared with conventional rate-adaptive pacing in patients with sinus node dysfunctions
Europace · 2024
DOI: 10.1093/europace/euae175 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Europace, 2024. Verfasst von Ennio C L Pisanò und 25 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology and Intensive Care Unit, Vito Fazzi Hospital, Lecce, Italy. Hauptthemen laut MEDLINE: Atrial Fibrillation, Sick Sinus Syndrome, Cardiac Pacing, Artificial, Pacemaker, Artificial. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Biotronik SE & Co KG.
Abstract (Originalsprache)
Aims
Subclinical atrial fibrillation (AF) is associated with increased risk of progression to clinical AF, stroke, and cardiovascular death. We hypothesized that in pacemaker patients requiring dual-chamber rate-adaptive (DDDR) pacing, closed loop stimulation (CLS) integrated into the circulatory control system through intra-cardiac impedance monitoring would reduce the occurrence of atrial high-rate episodes (AHREs) compared with conventional DDDR pacing. Methods and results Patients with sinus node dysfunctions (SNDs) and an implanted pacemaker or defibrillator were randomly allocated to dual-chamber CLS (n = 612) or accelerometer-based DDDR pacing (n = 598) and followed for 3 years. The primary endpoint was time to the composite endpoint of the first AHRE lasting ≥6 min, stroke, or transient ischaemic attack (TIA). All AHREs were independently adjudicated using intra-cardiac electrograms. The incidence of the primary endpoint was lower in the CLS arm (50.6%) than in the DDDR arm (55.7%), primarily due to the reduction in AHREs lasting between 6 h and 7 days. Unadjusted site-stratified hazard ratio (HR) for CLS vs. DDDR was 0.84 [95% confidence interval (CI), 0.72–0.99; P = 0.035]. After adjusting for CHA2DS2-VASc score, the HR remained 0.84 (95% CI, 0.71–0.99; P = 0.033). In subgroup analyses of AHRE incidence, the incremental benefit of CLS was greatest in patients without atrioventricular block (HR, 0.77; P = 0.008) and in patients without AF history (HR, 0.73; P = 0.009). The contribution of stroke/TIA to the primary endpoint (1.3%) was low and not statistically different between study arms.
Conclusion
Dual-chamber CLS in patients with SND is associated with a significantly lower AHRE incidence than conventional DDDR pacing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiology and Intensive Care Unit, Vito Fazzi Hospital, Lecce, Italy.
- Cardiology, G. Rodolico-San Marco University Hospital, Catania, Italy.
- Clinical and Interventional Arrhythmology, Sant'Anna e San Sebastiano Hospital, Caserta, Italy.
- Department of Advanced Biomedical Sciences, Federico II University of Naples, Naples, Italy.
- Clinical and Interventional Arrhythmology, Santa Maria Hospital, Terni, Italy.
- Cardiology, Bolognini Hospital, Seriate, Italy.
ORCID-Profile: Ennio C L Pisanò, Antonio Rapacciuolo, Ludovico Lazzari, Gemma Pelargonio, Giuseppe Arena, Béla Merkely, Lian-Yu Lin, Il-Young Oh, Emanuele Bertaglia, Davide Saporito, Antonino Nicosia, Aldo Coppolino, Chi Keong Ching, Álvaro Marco Del Castillo, Xi Su, Martina Del Maestro, Daniele Giacopelli, Alessio Gargaro, Giovanni L Botto
Förderung
- Biotronik SE & Co KG
Zitieren
APA
Pisanò, E. C. L., Calvi, V., Viscusi, M., Rapacciuolo, A., Lazzari, L., Bontempi, L., Pelargonio, G., Arena, G., Caccavo, V., Wang, C. C., Merkely, B., Lin, L. Y., Oh, I. Y., Bertaglia, E., Saporito, D., Menichelli, M., Nicosia, A., Carretta, D. M., Coppolino, A., …, & Botto, G. L. (2024). Closed loop stimulation reduces the incidence of atrial high-rate episodes compared with conventional rate-adaptive pacing in patients with sinus node dysfunctions. Europace. https://doi.org/10.1093/europace/euae175
Vancouver
Pisanò ECL, Calvi V, Viscusi M, Rapacciuolo A, Lazzari L, Bontempi L, et al. Closed loop stimulation reduces the incidence of atrial high-rate episodes compared with conventional rate-adaptive pacing in patients with sinus node dysfunctions. Europace. 2024. doi:10.1093/europace/euae175
BibTeX
@article{Pisan2024,
author = {Pisanò, Ennio C L and Calvi, Valeria and Viscusi, Miguel and Rapacciuolo, Antonio and Lazzari, Ludovico and Bontempi, Luca and Pelargonio, Gemma and Arena, Giuseppe and Caccavo, Vincenzo and Wang, Chun-Chieh and Merkely, Béla and Lin, Lian-Yu and Oh, Il-Young and Bertaglia, Emanuele and Saporito, Davide and Menichelli, Maurizio and Nicosia, Antonino and Carretta, Domenico M and Coppolino, Aldo and Ching, Chi Keong and Del Castillo, Álvaro Marco and Su, Xi and Del Maestro, Martina and Giacopelli, Daniele and Gargaro, Alessio and Botto, Giovanni L},
title = {Closed loop stimulation reduces the incidence of atrial high-rate episodes compared with conventional rate-adaptive pacing in patients with sinus node dysfunctions},
journal = {Europace},
year = {2024},
doi = {10.1093/europace/euae175}
}
EUVIMED