Use of three-dimensional electroanatomic mapping for epicardial access: needle tracking, electrographic characteristics, and clinical application
Europace · 2024
DOI: 10.1093/europace/euae089 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Europace, 2024. Verfasst von Ronghui Yu und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Pericardium, Imaging, Three-Dimensional, Needles, Electrophysiologic Techniques, Cardiac. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Beijing Municipal Science and Technology Commission, National Nature Science Foundation of China.
Abstract (Originalsprache)
Aims
Pericardiocentesis is usually completed under fluoroscopy. The electroanatomic mapping (EAM) system allows visualizing puncture needle tip (NT) while displaying the electrogram recorded from NT, making it possible to obtain epicardial access (EA) independent of fluoroscopy. This study was designed to establish and validate a technique by which EA is obtained under guidance of three-dimensional (3D) EAM combined with NT electrogram. Methods and results 3D shell of the heart was generated, and the NT was made trackable in the EAM system. Unipolar NT electrogram was continuously monitored. Penetration into pericardial sac was determined by an increase in NT potential amplitude and an injury current. A long guidewire of which the tip was also visible in the EAM system was advanced to confirm EA. Epicardial access was successfully obtained without complication in 13 pigs and 22 patients. In the animals, NT potential amplitude was 3.2 ± 1.0 mV when it was located in mediastinum, 5.2 ± 1.6 mV when in contact with fibrous pericardium, and 9.8 ± 2.8 mV after penetrating into pericardial sac (all P ≤ 0.001). In human subjects, it measured 1.54 ± 0.40 mV, 3.61 ± 1.08 mV, and 7.15 ± 2.88 mV, respectively (all P < 0.001). Fluoroscopy time decreased in every 4–5 cases (64 ± 15, 23 ± 17, and 0 s for animals 1–4, 5–8, 9–13, respectively, P = 0.01; 44 ± 23, 31 ± 18, 4±7 s for patients 1–7, 8–14, 15–22, respectively, P < 0.001). In five pigs and seven patients, EA was obtained without X-ray exposure.
Conclusion
By tracking NT in the 3D EAM system and continuously monitoring the NT electrogram, it is feasible and safe to obtain EA with minimum or no fluoroscopic guidance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
- Department of Cardiology, The First Affiliated Hospital of Anhui Medical University, Hefei, China.
- Department of Cardiology, Suzhou Kowloon Hospital, Shanghai Jiaotong University School of Medicine, Suzhou, China.
- Department of Cardiology, Shanxi Cardiovascular Hospital, Shanxi Institute of Cardiovascular Diseases, Taiyuan, China.
- Department of Cardiovascular Medicine, Mayo Clinic, Scottsdale, AZ, USA.
- Division of Cardiology, Banner University Medical Center Phoenix, University of Arizona College of Medicine -Phoenix, 1111 E. McDowell Road, Phoenix, AZ 85006, USA.
ORCID-Profile: Binquan You, Haixiong Wang, Songnan Wen, Peter J Weiss, Michael Zawaneh, Wilber Su, Roderick Tung, Xin Zhao, Ribo Tang, Rong Bai
Förderung
- Beijing Municipal Science and Technology Commission
- National Nature Science Foundation of China
Zitieren
APA
Yu, R., Liu, N., You, B., Wang, H., Ruan, Y., Wen, S., Weiss, P. J., Zawaneh, M., Su, W., Tung, R., Zhao, X., Wang, W., Tang, R., & Bai, R. (2024). Use of three-dimensional electroanatomic mapping for epicardial access: needle tracking, electrographic characteristics, and clinical application. Europace. https://doi.org/10.1093/europace/euae089
Vancouver
Yu R, Liu N, You B, Wang H, Ruan Y, Wen S, et al. Use of three-dimensional electroanatomic mapping for epicardial access: needle tracking, electrographic characteristics, and clinical application. Europace. 2024. doi:10.1093/europace/euae089
BibTeX
@article{Yu2024,
author = {Yu, Ronghui and Liu, Nian and You, Binquan and Wang, Haixiong and Ruan, Yanfei and Wen, Songnan and Weiss, Peter J and Zawaneh, Michael and Su, Wilber and Tung, Roderick and Zhao, Xin and Wang, Wei and Tang, Ribo and Bai, Rong},
title = {Use of three-dimensional electroanatomic mapping for epicardial access: needle tracking, electrographic characteristics, and clinical application},
journal = {Europace},
year = {2024},
doi = {10.1093/europace/euae089}
}
EUVIMED