Three-dimensional intracardiac echocardiography for left atrial appendage sizing and percutaneous occlusion guidance
Europace · 2023
DOI: 10.1093/europace/euae010 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, 2023. Verfasst von Domenico G Della Rocca und 24 weiteren Autor:innen. Beteiligte Einrichtung: Texas Cardiac Arrhythmia Institute, St. David's Medical Center, 3000 N Interstate Hwy 35 Suite 720, Austin, TX, USA. Hauptthemen laut MEDLINE: Atrial Appendage, Atrial Fibrillation. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Aims
Left atrial appendage (LAA) imaging is critical during percutaneous occlusion procedures. 3D-intracardiac echocardiography (ICE) features direct visualization of LAA from multiple cross-sectional planes at a time. We aimed at reporting procedural success of 3D-ICE-guided LAA occlusion and the correlation between pre-procedural transoesophageal echocardiography (TEE) and intraprocedural 3D-ICE for LAA sizing. Methods and results Among 274 patients undergoing left atrial appendage occlusion (LAAO) with a Watchman FLX, periprocedural ICE guidance was achieved via a commercially available 2D-ICE catheter (220 patients) or a novel (NUVISION™) 3D-ICE one (54 patients). Primary endpoint was a composite of procedural success and LAA sealing at follow-up TEE. Secondary endpoint was a composite of periprocedural device recapture/resizing plus presence of leaks ≥ 3 mm at follow-up TEE. 3D-ICE measurements of maximum landing zone correlated highly with pre-procedural TEE reference values [Pearson’s: 0.94; P < 0.001; bias: −0.06 (−2.39, 2.27)]. The agreement between 3D-ICE-based device selection and final device size was 96.3% vs. 79.1% with 2D-ICE (P = 0.005). The incidence of the primary endpoint was 98.1% with 3D-ICE and 97.3% with 2D-ICE (P = 0.99). 2D-ICE patients had a trend towards a higher incidence of periprocedural device recapture/redeployment (31.5% vs. 44.5%; P = 0.09). The secondary endpoint occurred in 31.5% of 3D-ICE patients vs. 45.9% of 2D-ICE ones (P = 0.065).
Conclusion
Intracardiac echocardiography-guided LAAO showed a very high success, with no major adverse events. A very high level of agreement for LAA sizing was found between pre-procedural TEE and periprocedural 3D-ICE. 3D-ICE performed significantly better than 2D-ICE for FLX size selection and may provide better guidance during device deployment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, 3000 N Interstate Hwy 35 Suite 720, Austin, TX, USA.
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Av. du Laerbeek 101, 109…
- Arrhythmology Unit, Ospedale San Giovanni Calibita, Fatebefratelli Isola Tiberina-Gemelli Isola, Rome, Italy.
- Department of Clinical, Internal, Anesthesiologist and Cardiovascular Sciences, Sapienza University of Rome, Viale del Policlinico 155, 00161 Rome, Italy.
- Section of Cardiac Pacing and Electrophysiology, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, USA.
- Kansas City Heart Rhythm Institute, 5100 W 110th St Second Floor, Overland Park, KS, USA.
ORCID-Profile: Domenico G Della Rocca, Michele Magnocavallo, Carola Gianni, Sanghamitra Mohanty, Amin Al-Ahmad, Mohamed Bassiouny, Marialessia Denora, Vincenzo Mirco La Fazia, Carlo Lavalle, Gerald J Gallinghouse, Pasquale Santangeli, Marco Polselli, Andrea Sarkozy, Giampaolo Vetta, Javier E Sanchez, Luigi Pannone, Gian-Battista Chierchia, Carlo de Asmundis, Luigi Di Biase, Dhanunjaya Lakkireddy, David J Burkhardt, Rodney P Horton, Andrea Natale
Zitieren
APA
Della Rocca, D. G., Magnocavallo, M., Gianni, C., Mohanty, S., Al-Ahmad, A., Bassiouny, M., Denora, M., La Fazia, V. M., Lavalle, C., Gallinghouse, G. J., Santangeli, P., Polselli, M., Sarkozy, A., Vetta, G., Ahmed, A., Sanchez, J. E., Pannone, L., Chierchia, G. B., Tschopp, D. R., …, & Natale, A. (2023). Three-dimensional intracardiac echocardiography for left atrial appendage sizing and percutaneous occlusion guidance. Europace. https://doi.org/10.1093/europace/euae010
Vancouver
Della Rocca DG, Magnocavallo M, Gianni C, Mohanty S, Al-Ahmad A, Bassiouny M, et al. Three-dimensional intracardiac echocardiography for left atrial appendage sizing and percutaneous occlusion guidance. Europace. 2023. doi:10.1093/europace/euae010
BibTeX
@article{DellaRocca2023,
author = {Della Rocca, Domenico G and Magnocavallo, Michele and Gianni, Carola and Mohanty, Sanghamitra and Al-Ahmad, Amin and Bassiouny, Mohamed and Denora, Marialessia and La Fazia, Vincenzo Mirco and Lavalle, Carlo and Gallinghouse, Gerald J and Santangeli, Pasquale and Polselli, Marco and Sarkozy, Andrea and Vetta, Giampaolo and Ahmed, Adnan and Sanchez, Javier E and Pannone, Luigi and Chierchia, Gian-Battista and Tschopp, David R and de Asmundis, Carlo and Di Biase, Luigi and Lakkireddy, Dhanunjaya and Burkhardt, David J and Horton, Rodney P and Natale, Andrea},
title = {Three-dimensional intracardiac echocardiography for left atrial appendage sizing and percutaneous occlusion guidance},
journal = {Europace},
year = {2023},
doi = {10.1093/europace/euae010}
}
EUVIMED