Performance and safety of temperature- and flow-controlled radiofrequency ablation for ventricular arrhythmia
Europace · 2023
DOI: 10.1093/europace/euad372 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, 2023. Verfasst von Richard Kobza und 7 weiteren Autor:innen. Beteiligte Einrichtung: Heart Center, Luzerner Kantonsspital, Zentralstrasse 1, Lucerne 6004, Switzerland. Hauptthemen laut MEDLINE: Radiofrequency Ablation, Tachycardia, Ventricular. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Aims
High-power ablation is effective for ventricular arrhythmia ablation; however, it increases the risk of steam pops. The aim of this study was to define the safety and efficacy of QMODE ablation in the ventricle and the risk of steam pop. Methods and results Consecutive patients undergoing ventricular ablation using QDOT were included in a prospective single-centre registry. Procedural data, complications, and follow-up were systematically analysed and compared with a historical ventricular tachycardia (VT) and premature ventricular complexes (PVC) cohort ablated using STSF. QMODE (≤50 W) ablation was performed in 107 patients [age 62 ± 13 years; 76% male; VT (n = 41); PVC (n = 66)]. A total of 2456 applications were analysed [power: 45.9 ± 5.0 W with minimal power titration (90% > 95% max power); duration 26 ± 8 s; impedance drop 9.4 ± 4.7 Ω; ablation index: 569 ± 163; mean–max temperature 44.3 ± 2.6°C]. Ventricular tachycardia ablation was associated with shorter radiofrequency (RF) time and a trend towards shorter procedure times using QDOT (QDOT vs. STSF: 20.1 ± 14.7 vs. 31 ± 17 min; P = 0.002, 151 ± 59 vs. 172 ± 48 min; P = 0.06). Complications, VT recurrence, and mortality rates were comparable (QDOT vs. STSF: 2% vs. 2%; P = 0.9, 24% vs. 27%; P = 0.82, and 2% vs. 4%; P = 0.67). Five audible steam pops (0.02%) occurred. Premature ventricular complex ablation was associated with comparable RF and procedure times (QDOT vs. STSF: 4.8 ± 4.6 vs. 3.9 ± 3.1 min; P = 0.25 and 96.1 ± 31.9 vs. 94.6 ± 24.7 min; P = 0.75). Complication and PVC recurrence were also comparable (QDOT vs. STSF: 0% vs. 3%; P = 0.17 and 19% vs. 22%; P = 0.71).
Conclusion
Ventricular ablation using QMODE ≤ 50 W is safe and effective for both VT and PVC ablation and is associated with a low risk for steam pop.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Heart Center, Luzerner Kantonsspital, Zentralstrasse 1, Lucerne 6004, Switzerland.
- Clinical Support, Biosense Webster, Zug, Switzerland.
- Department of Cardiac Electrophysiology, Liverpool Heart and Chest Hospital, Liverpool, UK.
- Cardiology Department, University Hospital Zürich, Zürich, Switzerland.
- Department of Cardiology, Ordensklinikum Linz Elisabethinen, Linz, Austria.
ORCID-Profile: Richard Kobza, Sophie Rissotto, Christian Grebmer, Firat Duru, Helmut Pürerfellner, Benjamin Berte
Zitieren
APA
Kobza, R., Hilfiker, G., Rissotto, S., Mahida, S., Grebmer, C., Duru, F., Pürerfellner, H., & Berte, B. (2023). Performance and safety of temperature- and flow-controlled radiofrequency ablation for ventricular arrhythmia. Europace. https://doi.org/10.1093/europace/euad372
Vancouver
Kobza R, Hilfiker G, Rissotto S, Mahida S, Grebmer C, Duru F, et al. Performance and safety of temperature- and flow-controlled radiofrequency ablation for ventricular arrhythmia. Europace. 2023. doi:10.1093/europace/euad372
BibTeX
@article{Kobza2023,
author = {Kobza, Richard and Hilfiker, Gabriela and Rissotto, Sophie and Mahida, Saagar and Grebmer, Christian and Duru, Firat and Pürerfellner, Helmut and Berte, Benjamin},
title = {Performance and safety of temperature- and flow-controlled radiofrequency ablation for ventricular arrhythmia},
journal = {Europace},
year = {2023},
doi = {10.1093/europace/euad372}
}
EUVIMED