Durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review
Europace · 2023
DOI: 10.1093/europace/euad335 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Europace, 2023. Verfasst von Teodor Serban und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University Hospital of Basel, Petersgraben 4, 4031 Basel, Switzerland. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pulmonary Veins, Cryosurgery, Catheter Ablation. Die Arbeit wurde bisher 45-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Aims
Pulmonary vein isolation (PVI) plays a central role in the interventional treatment of atrial fibrillation (AF). Uncertainties remain about the durability of ablation lesions from different energy sources. We aimed to systematically review the durability of ablation lesions associated with various PVI-techniques using different energy sources for the treatment of AF. Methods and results Structured systematic database search for articles published between January 2010 and January 2023 reporting PVI-lesion durability as evaluated in the overall cohort through repeat invasive remapping during follow-up. Studies evaluating only a proportion of the initial cohort in redo procedures were excluded. A total of 19 studies investigating 1050 patients (mean age 60 years, 31% women, time to remap 2–7 months) were included. In a pooled analysis, 99.7% of the PVs and 99.4% of patients were successfully ablated at baseline and 75.5% of the PVs remained isolated and 51% of the patients had all PVs persistently isolated at follow-up across all energy sources. In a pooled analysis of the percentages of PVs durably isolated during follow-up, the estimates of RFA were the lowest of all energy sources at 71% (95% CI 69–73, 11 studies), but comparable with cryoballoon (79%, 95%CI 74–83, 3 studies). Higher durability percentages were reported in PVs ablated with laser-balloon (84%, 95%CI 78–89, one study) and PFA (87%, 95%CI 84–90, 2 studies).
Conclusion
We observed no significant difference in the durability of the ablation lesions of the four evaluated energies after adjusting for procedural and baseline populational characteristics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, University Hospital of Basel, Petersgraben 4, 4031 Basel, Switzerland.
- Cardiovascular Research Institute Basel, Spitalstrasse 2, 4056 Basel, Switzerland.
- Department of Cardiology, Rush Medical Centre, Chicago, IL, USA.
- Department of Cardiology, Triemli Stadtspital, Zürich, Switzerland.
- Department of Cardiology, Cook County Health, Chicago, IL, USA.
ORCID-Profile: Teodor Serban, Diego Mannhart, Qurrat-Ul-Ain Abid, Sorin Lazar, Philipp Krisai, Sven Knecht, Michael Kühne, Christian Sticherling, Jeanne du Fay de Lavallaz, Patrick Badertscher
Zitieren
APA
Serban, T., Mannhart, D., Abid, Q. U., Höchli, A., Lazar, S., Krisai, P., Bettelini, A. S., Knecht, S., Kühne, M., Sticherling, C., du Fay de Lavallaz, J., & Badertscher, P. (2023). Durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review. Europace. https://doi.org/10.1093/europace/euad335
Vancouver
Serban T, Mannhart D, Abid QU, Höchli A, Lazar S, Krisai P, et al. Durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review. Europace. 2023. doi:10.1093/europace/euad335
BibTeX
@article{Serban2023,
author = {Serban, Teodor and Mannhart, Diego and Abid, Qurrat-Ul-Ain and Höchli, Andres and Lazar, Sorin and Krisai, Philipp and Bettelini, Arianna Sofia and Knecht, Sven and Kühne, Michael and Sticherling, Christian and du Fay de Lavallaz, Jeanne and Badertscher, Patrick},
title = {Durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review},
journal = {Europace},
year = {2023},
doi = {10.1093/europace/euad335}
}
EUVIMED