Electrographic flow mapping of persistent atrial fibrillation: intra- and inter-procedure reproducibility in the absence of ‘ground truth’
Europace · 2023
DOI: 10.1093/europace/euad308 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, 2023. Verfasst von Vivek Y Reddy und 8 weiteren Autor:innen. Beteiligte Einrichtung: Helmsley Electrophysiology Center, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, PO Box 1030, NewYork, NY 10029, USA. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Pulmonary Veins. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Ablacon.
Abstract (Originalsprache)
Aims
Validating mapping systems that identify atrial fibrillation (AF) sources (focal/rotational activity) is confounded by the absence of ground truth. A key concern of prior mapping technologies is spatiotemporal instability, manifesting as poor map reproducibility. Electrographic flow (EGF) employs a novel algorithm that visualizes atrial electrical wavefront propagation to identify putative AF sources. We analysed both intra- (3 min) and inter- (>3 months) procedure EGF map reproducibility. Methods and results In 23 persistent AF patients, after pulmonary vein isolation (PVI), EGF maps were generated from 3 serial 1 min recordings using a 64-electrode basket mapping catheter (triplets) at right and left atrial locations. Source prevalence from map triplets was compared between recordings. Per protocol, 12 patients returned for 3-month remapping (1 non-inducible): index procedure post-PVI EGF maps were compared with initial EGF remapping at 3-month redo. Intra-procedure reproducibility: analysing 224 map triplets (111 right atrium, 113 left atrium) revealed a high degree of map consistency with minimal min-to-min shifts: 97 triplets (43%), exact match of leading sources on all 3 maps; 95 triplets (42%), leading source within 1 electrode space on 2 of 3 maps; and 32 triplets (14%), chaotic leading source pattern. Average deviation in source prevalence over 60 s was low (6.4%). Inter-procedure reproducibility: spatiotemporal stability of EGF mapping >3 months was seen in 16 of 18 (89%) sources mapped in 12 patients with (re)inducible AF.
Conclusion
Electrographic flow mapping generates reproducible intra- and inter-procedural maps, providing rationale for randomized clinical trials targeting these putative AF sources.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Helmsley Electrophysiology Center, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, PO Box 1030, NewYork, NY 10029, USA.
- Department of Cardiology, Homolka Hospital, Roentgenova 37/2, Prague 5, Czech Republic.
- Ablacon Inc.,Wheat Ridge, CO, USA.
ORCID-Profile: Vivek Y Reddy, Melissa H Kong, Moritoshi Funasako, Kentaro Minami, Peter Ruppersberg, Petr Neuzil
Förderung
- Ablacon
Zitieren
APA
Reddy, V. Y., Kong, M. H., Petru, J., Maan, A., Funasako, M., Minami, K., Ruppersberg, P., Dukkipati, S., & Neuzil, P. (2023). Electrographic flow mapping of persistent atrial fibrillation: intra- and inter-procedure reproducibility in the absence of ‘ground truth’. Europace. https://doi.org/10.1093/europace/euad308
Vancouver
Reddy VY, Kong MH, Petru J, Maan A, Funasako M, Minami K, et al. Electrographic flow mapping of persistent atrial fibrillation: intra- and inter-procedure reproducibility in the absence of ‘ground truth’. Europace. 2023. doi:10.1093/europace/euad308
BibTeX
@article{Reddy2023,
author = {Reddy, Vivek Y and Kong, Melissa H and Petru, Jan and Maan, Abhishek and Funasako, Moritoshi and Minami, Kentaro and Ruppersberg, Peter and Dukkipati, Srinivas and Neuzil, Petr},
title = {Electrographic flow mapping of persistent atrial fibrillation: intra- and inter-procedure reproducibility in the absence of ‘ground truth’},
journal = {Europace},
year = {2023},
doi = {10.1093/europace/euad308}
}
EUVIMED