Real-world evidence on the association between cardiac implantable electronic device infection and all-cause mortality
Europace · 02.08.2023 · 25 (9)
DOI: 10.1093/europace/euad274 ↗Kurz gefasst
Leserbrief in der Zeitschrift Europace, online erschienen am 13.09.2023. Verfasst von Md Shajedur Rahman Shawon und 6 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Big Data Research in Health, University of New South Wales, Level 2, AGSM Building (G27), Sydney, NSW 2052, Australia. Hauptthemen laut MEDLINE: Electronics, Heart Diseases. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NHMRC, Medtronic Australasia Pty Ltd.
Abstract (Originalsprache)
Aims
An infection following cardiac implantable electronic device (CIED) procedure is a serious complication, but its association with all-cause mortality is inconsistent across observational studies. To quantify the association between CIED infection and all-cause mortality in a large, contemporary cohort from New South Wales, Australia. Methods and results This retrospective cohort study used linked hospital and mortality data and included all patients aged >18 years who underwent a CIED procedure between July 2017 and September 2022. Cardiac implantable electronic device infection was defined by the presence of relevant diagnosis codes. Cox regression to estimate adjusted hazard ratios (aHRs) with 95% confidence intervals (CIs) for the association of CIED infection with mortality, at 1-year, and at the end of follow-up, with CIED infection included as a time-dependent variable, and other potential risk factors for mortality included as fixed covariates. We followed 37,750 patients with CIED procedures {36% female, mean age [standard deviation (SD)] 75.8 [12.7] years}, and 487 (1.3%) CIED infections were identified. We observed 5771 (15.3%) deaths during an average follow-up of 25.2 (SD 16.8) months. Compared with no infection group, patients with CIED infection had a higher Kaplan-Meier mortality rate (19.4 vs. 6.8%) and adjusted hazard of mortality (aHR 2.73, 95% CI 2.10−3.54) at 12 months post-procedure. These differences were attenuated but still remained significant at the end of follow-up (aHR 1.83, 95% CI 1.52−2.19).
Conclusion
In a complete, state–wide cohort of CIED patients, infection was associated with higher risks of both short–term and long–term mortality.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Centre for Big Data Research in Health, University of New South Wales, Level 2, AGSM Building (G27), Sydney, NSW 2052, Australia.
- Medtronic Australasia Pty Ltd., Sydney, NSW, Australia.
- Department of Cardiology, Prince of Wales Hospital, Sydney, Australia.
- UNSW Medicine, UNSW Sydney, NSW, Australia.
ORCID-Profile: Md Shajedur Rahman Shawon, Oluwadamisola Temilade Sotade, Liesl Strachan, Gabrielle Challis, Sze-Yuan Ooi, Louisa R Jorm
Förderung
- NHMRC
- Medtronic Australasia Pty Ltd
Zitieren
APA
Shawon, M. S. R., Sotade, O. T., Hill, M., Strachan, L., Challis, G., Ooi, S. Y., & Jorm, L. R. (2023). Real-world evidence on the association between cardiac implantable electronic device infection and all-cause mortality. Europace, 25(9). https://doi.org/10.1093/europace/euad274
Vancouver
Shawon MSR, Sotade OT, Hill M, Strachan L, Challis G, Ooi SY, et al. Real-world evidence on the association between cardiac implantable electronic device infection and all-cause mortality. Europace. 2023;25(9). doi:10.1093/europace/euad274
BibTeX
@article{Shawon2023,
author = {Shawon, Md Shajedur Rahman and Sotade, Oluwadamisola Temilade and Hill, Michelle and Strachan, Liesl and Challis, Gabrielle and Ooi, Sze-Yuan and Jorm, Louisa R},
title = {Real-world evidence on the association between cardiac implantable electronic device infection and all-cause mortality},
journal = {Europace},
year = {2023},
volume = {25},
number = {9},
doi = {10.1093/europace/euad274}
}
EUVIMED