Comparison of methods for delivering cardiac resynchronization therapy: an acute electrical and haemodynamic within-patient comparison of left bundle branch area, His bundle, and biventricular pacing

Nadine Ali iD, Ahran D Arnold iD, Alejandra A Miyazawa iD, Daniel Keene iD, Ji-Jian Chow iD, Ian Little, Nicholas S Peters iD, Prapa Kanagaratnam iD, Norman Qureshi iD, Fu Siong Ng iD, Nick W F Linton iD, David C Lefroy iD und 7 weitere

EP Europace · 2023

DOI: 10.1093/europace/euac245 ↗

Kurz gefasst

Kommentar in der Zeitschrift EP Europace, 2023. Verfasst von Nadine Ali und 18 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, National Heart and Lung Institute, Imperial College London, Hammersmith Hospital Du Cane Road, London W120HS, UK. Hauptthemen laut MEDLINE: Cardiac Resynchronization Therapy, Heart Failure. Die Arbeit wurde bisher 61-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: British Heart Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Left bundle branch area pacing (LBBAP) is a promising method for delivering cardiac resynchronization therapy (CRT), but its relative physiological effectiveness compared with His bundle pacing (HBP) is unknown. We conducted a within-patient comparison of HBP, LBBAP, and biventricular pacing (BVP). Methods and results Patients referred for CRT were recruited. We assessed electrical response using non-invasive mapping, and acute haemodynamic response using a high-precision haemodynamic protocol. Nineteen patients were recruited: 14 male, mean LVEF of 30%. Twelve had time for BVP measurements. All three modalities reduced total ventricular activation time (TVAT), (ΔTVATHBP -43 ± 14 ms and ΔTVATLBBAP −35 ± 20 ms vs. ΔTVATBVP −19 ± 30 ms, P = 0.03 and P = 0.1, respectively). HBP produced a significantly greater reduction in TVAT compared with LBBAP in all 19 patients (−46 ± 15 ms, −36 ± 17 ms, P = 0.03). His bundle pacing and LBBAP reduced left ventricular activation time (LVAT) more than BVP (ΔLVATHBP −43 ± 16 ms, P < 0.01 vs. BVP, ΔLVATLBBAP −45 ± 17 ms, P < 0.01 vs. BVP, ΔLVATBVP −13 ± 36 ms), with no difference between HBP and LBBAP (P = 0.65). Acute systolic blood pressure was increased by all three modalities. In the 12 with BVP, greater improvement was seen with HBP and LBBAP (6.4 ± 3.8 mmHg BVP, 8.1 ± 3.8 mmHg HBP, P = 0.02 vs. BVP and 8.4 ± 8.2 mmHg for LBBAP, P = 0.3 vs. BVP), with no difference between HBP and LBBAP (P = 0.8).

Conclusion

HBP delivered better ventricular resynchronization than LBBAP because right ventricular activation was slower during LBBAP. But LBBAP was not inferior to HBP with respect to LV electrical resynchronization and acute haemodynamic response.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiac Resynchronization TherapyHeart FailureHumansMaleBundle of HisBundle-Branch BlockElectrocardiographyTreatment OutcomeHemodynamicsCardiac Pacing, Artificial

Stichwörter der Autor:innen

Biventricular pacingHis bundle pacingLeft bundle branch area pacing

Autor:innen und Institutionen

  • Department of Cardiology, National Heart and Lung Institute, Imperial College London, Hammersmith Hospital Du Cane Road, London W120HS, UK.
  • Medtronic Limited, Building 9, Croxley Green Business Park, Watford WD18 8WW, UK.
  • Department of Cardiology, St Richards Hospital, University Hospitals Sussex NHS Foundation Trust., Spitalfield Ln, Chichester PO19 6SE, UK.
  • Department of Cardiology, St Bartholomew's Hospital and North Middlesex University Hospital, W Smithfield, London EC1A 7BE, UK.

ORCID-Profile: Nadine Ali, Ahran D Arnold, Alejandra A Miyazawa, Daniel Keene, Ji-Jian Chow, Nicholas S Peters, Prapa Kanagaratnam, Norman Qureshi, Fu Siong Ng, Nick W F Linton, David C Lefroy, Darrel P Francis, Lim Phang Boon, Mark A Tanner, Matthew J Shun-Shin, Graham D Cole, Zachary I Whinnett

Förderung

  • British Heart Foundation

Zitieren

APA

Ali, N., Arnold, A. D., Miyazawa, A. A., Keene, D., Chow, J. J., Little, I., Peters, N. S., Kanagaratnam, P., Qureshi, N., Ng, F. S., Linton, N. W. F., Lefroy, D. C., Francis, D. P., Phang Boon, L., Tanner, M. A., Muthumala, A., Shun-Shin, M. J., Cole, G. D., & Whinnett, Z. I. (2023). Comparison of methods for delivering cardiac resynchronization therapy: an acute electrical and haemodynamic within-patient comparison of left bundle branch area, His bundle, and biventricular pacing. EP Europace. https://doi.org/10.1093/europace/euac245

Vancouver

Ali N, Arnold AD, Miyazawa AA, Keene D, Chow JJ, Little I, et al. Comparison of methods for delivering cardiac resynchronization therapy: an acute electrical and haemodynamic within-patient comparison of left bundle branch area, His bundle, and biventricular pacing. EP Europace. 2023. doi:10.1093/europace/euac245

BibTeX
@article{Ali2023,
  author = {Ali, Nadine and Arnold, Ahran D and Miyazawa, Alejandra A and Keene, Daniel and Chow, Ji-Jian and Little, Ian and Peters, Nicholas S and Kanagaratnam, Prapa and Qureshi, Norman and Ng, Fu Siong and Linton, Nick W F and Lefroy, David C and Francis, Darrel P and Phang Boon, Lim and Tanner, Mark A and Muthumala, Amal and Shun-Shin, Matthew J and Cole, Graham D and Whinnett, Zachary I},
  title = {Comparison of methods for delivering cardiac resynchronization therapy: an acute electrical and haemodynamic within-patient comparison of left bundle branch area, His bundle, and biventricular pacing},
  journal = {EP Europace},
  year = {2023},
  doi = {10.1093/europace/euac245}
}
Kostenlos starten →