Electromechanical factors associated with favourable outcome in cardiac resynchronization therapy
EP Europace · 2023
DOI: 10.1093/europace/euac157 ↗Kurz gefasst
Fachartikel in der Zeitschrift EP Europace, 2023. Verfasst von Francesco Maffessanti und 13 weiteren Autor:innen. Beteiligte Einrichtung: Center for Computational Medicine in Cardiology, Università della Svizzera Italiana, Lugano, Switzerland. Hauptthemen laut MEDLINE: Cardiac Resynchronization Therapy, Heart Failure. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swiss National Science Foundation, Swiss Heart Foundation, Biologic Delivery Systems.
Abstract (Originalsprache)
Aims
Electromechanical coupling in patients receiving cardiac resynchronization therapy (CRT) is not fully understood. Our aim was to determine the best combination of electrical and mechanical substrates associated with effective CRT. Methods and results Sixty-two patients were prospectively enrolled from two centres. Patients underwent 12-lead electrocardiogram (ECG), cardiovascular magnetic resonance (CMR), echocardiography, and anatomo-electromechanical mapping (AEMM). Remodelling was measured as the end-systolic volume (ΔESV) decrease at 6 months. CRT was defined effective with ΔESV ≤ −15%. QRS duration (QRSd) was measured from ECG. Area strain was obtained from AEMM and used to derive systolic stretch index (SSI) and total left-ventricular mechanical time. Total left-ventricular activation time (TLVAT) and transeptal time (TST) were derived from AEMM and ECG. Scar was measured from CMR. Significant correlations were observed between ΔESV and TST [rho = 0.42; responder: 50 (20–58) vs. non-responder: 33 (8–44) ms], TLVAT [−0.68; 81 (73–97) vs. 112 (96–127) ms], scar [−0.27; 0.0 (0.0–1.2) vs. 8.7 (0.0–19.1)%], and SSI [0.41; 10.7 (7.1–16.8) vs. 4.2 (2.9–5.5)], but not QRSd [−0.13; 155 (140–176) vs. 167 (155–177) ms]. TLVAT and SSI were highly accurate in identifying CRT response [area under the curve (AUC) > 0.80], followed by scar (AUC > 0.70). Total left-ventricular activation time (odds ratio = 0.91), scar (0.94), and SSI (1.29) were independent factors associated with effective CRT. Subjects with SSI >7.9% and TLVAT <91 ms all responded to CRT with a median ΔESV ≈ −50%, while low SSI and prolonged TLVAT were more common in non-responders (ΔESV ≈ −5%).
Conclusion
Electromechanical measurements are better associated with CRT response than conventional ECG variables. The absence of scar combined with high SSI and low TLVAT ensures effectiveness of CRT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Computational Medicine in Cardiology, Università della Svizzera Italiana, Lugano, Switzerland.
- Maria Cecilia Hospital, GVM Care and Research, Cotignola, Italy.
- Division of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland.
- Interventional Cardiac Electrophysiology Group, International Clinical Research Center, St. Anne's University Hospital Brno, Brno, Czech Republic.
- Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland.
- Division of Cardiology, Istituto Cardiocentro Ticino, Lugano, Switzerland.
ORCID-Profile: Francesco Maffessanti, Tomasz Jadczyk, Jacek Wilczek, Giulio Conte, Krzysztof S Gołba, Jolanta Biernat, Magdalena Cybulska, Guido Caluori, François Regoli, Rolf Krause, Wojciech Wojakowski, Frits W Prinzen, Angelo Auricchio
Förderung
- Swiss National Science Foundation
- Swiss Heart Foundation
- Biologic Delivery Systems
- Division of Biosense Webster a Johnson & Johnson Company
- Medical University of Silesia
- Anneliese and Mieczysław Koćwin Foundation Scholarship
Zitieren
APA
Maffessanti, F., Jadczyk, T., Wilczek, J., Conte, G., Caputo, M. L., Gołba, K. S., Biernat, J., Cybulska, M., Caluori, G., Regoli, F., Krause, R., Wojakowski, W., Prinzen, F. W., & Auricchio, A. (2023). Electromechanical factors associated with favourable outcome in cardiac resynchronization therapy. EP Europace. https://doi.org/10.1093/europace/euac157
Vancouver
Maffessanti F, Jadczyk T, Wilczek J, Conte G, Caputo ML, Gołba KS, et al. Electromechanical factors associated with favourable outcome in cardiac resynchronization therapy. EP Europace. 2023. doi:10.1093/europace/euac157
BibTeX
@article{Maffessanti2023,
author = {Maffessanti, Francesco and Jadczyk, Tomasz and Wilczek, Jacek and Conte, Giulio and Caputo, Maria Luce and Gołba, Krzysztof S and Biernat, Jolanta and Cybulska, Magdalena and Caluori, Guido and Regoli, François and Krause, Rolf and Wojakowski, Wojciech and Prinzen, Frits W and Auricchio, Angelo},
title = {Electromechanical factors associated with favourable outcome in cardiac resynchronization therapy},
journal = {EP Europace},
year = {2023},
doi = {10.1093/europace/euac157}
}
EUVIMED