Impact on nurse workload and patient satisfaction of atrioventricular junction ablation performed simultaneously with conduction system pacing using a superior approach from the pocket compared with the conventional femoral approach
European Journal of Cardiovascular Nursing · 21.10.2024 · 23 (7) · 746-755
DOI: 10.1093/eurjcn/zvae043 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift European Journal of Cardiovascular Nursing, online erschienen am 29.03.2024. Verfasst von Pietro Palmisano und 12 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Unit, 'Card. G. Panico' Hospital, Via S. Pio X, 4, 73039 Tricase, Italy. Hauptthemen laut MEDLINE: Patient Satisfaction, Atrial Fibrillation, Catheter Ablation, Workload. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben.
Abstract (Originalsprache)
Aims
Conduction system pacing (CSP) and atrioventricular junction ablation (AVJA) improve outcomes in patients with symptomatic, refractory atrial fibrillation (AF). Superior approach (SA) from the pocket, via the axillary or subclavian vein, has been recently proposed as an alternative to the conventional femoral access (FA) to perform AVJA. In this study, we compare the impact of these alternative approaches on nurse workload (NWL) and patient satisfaction. Methods and results This was a prospective, observational study enrolling consecutive patients undergoing simultaneous CSP and AVJA. Electrophysiology laboratory (EP Lab) NWL was calculated by using a self-developed model. Ward NWL was calculated using the MIDENF® validated scale. Patient satisfaction was collected using the Hospital Consumer Assessment of Healthcare Provider Systems questionnaire. A total of 119 patients were enrolled: in 50, AVJA was primarily attempted with SA, and in 69 with FA. Compared with FA, SA was associated with a lower EP Lab NWL (169.8 ± 26.7 vs. 202.7 ± 38.9 min; P < 0.001) and a lower Ward NWL (474.5 ± 184.8 vs. 808.6 ± 289.9 min; P < 0.001). Multivariate analysis identified SA as an independent predictor of lower EP Lab NWL [hazard ratio (HR) 4.60; P = 0.001] and of lower Ward NWL (HR 45.13; P < 0.001). Compared with FA, SA was associated with a higher patient-reported rating regarding their experience during hospital stay (P = 0.035) and the overall hospital evaluation (P = 0.026).
Conclusion
In patients undergoing simultaneous CSP and AVJA, the use of an SA for ablation is a valid alternative to conventional FA. Compared with FA, this approach significantly reduces NWL and is associated with greater patient satisfaction. Registration ClinicalTrials.gov: NCT03612635
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiology Unit, 'Card. G. Panico' Hospital, Via S. Pio X, 4, 73039 Tricase, Italy.
- Cardiology Unit, Department of Clinical and Experimental Medicine, University of Messina, Piazza Pugliatti, 1, 98122 Messina, Italy.
ORCID-Profile: Pietro Palmisano
Zitieren
APA
Palmisano, P., Sergi, C., Panico, V., Chiarillo, M. V., Chiuri, M. D., Martella, M. L., Stefanelli, G., Martella, D., Mauro, R., Ponzetta, M. A., Parlavecchio, A., Accogli, M., & Coluccia, G. (2024). Impact on nurse workload and patient satisfaction of atrioventricular junction ablation performed simultaneously with conduction system pacing using a superior approach from the pocket compared with the conventional femoral approach. European Journal of Cardiovascular Nursing, 23(7), 746-755. https://doi.org/10.1093/eurjcn/zvae043
Vancouver
Palmisano P, Sergi C, Panico V, Chiarillo MV, Chiuri MD, Martella ML, et al. Impact on nurse workload and patient satisfaction of atrioventricular junction ablation performed simultaneously with conduction system pacing using a superior approach from the pocket compared with the conventional femoral approach. European Journal of Cardiovascular Nursing. 2024;23(7):746-755. doi:10.1093/eurjcn/zvae043
BibTeX
@article{Palmisano2024,
author = {Palmisano, Pietro and Sergi, Cesario and Panico, Vincenzo and Chiarillo, Marco Valerio and Chiuri, Maria Domenica and Martella, Maria Lucia and Stefanelli, Gianluca and Martella, Deborah and Mauro, Raffaele and Ponzetta, Maria Antonietta and Parlavecchio, Antonio and Accogli, Michele and Coluccia, Giovanni},
title = {Impact on nurse workload and patient satisfaction of atrioventricular junction ablation performed simultaneously with conduction system pacing using a superior approach from the pocket compared with the conventional femoral approach},
journal = {European Journal of Cardiovascular Nursing},
year = {2024},
volume = {23},
number = {7},
pages = {746--755},
doi = {10.1093/eurjcn/zvae043}
}
EUVIMED