Refining reperfusion assessment with flat-panel detector CT: association with final infarct volume after endovascular thrombectomy
European Stroke Journal · 2026
DOI: 10.1093/esj/aakag104 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Stroke Journal, 2026. Verfasst von Junpei Koge und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Comprehensive Strokology, Fujita Health University School of Medicine, Toyoake, Japan. Hauptthemen laut MEDLINE: Thrombectomy, Endovascular Procedures, Reperfusion, Tomography, X-Ray Computed. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science (JSPS) KAKENHI.
Abstract (Originalsprache)
Introduction
Distal occlusion tracker (DOT) signs on immediate post-interventional flat-panel detector CT (FDCT) can identify residual vessel occlusions underestimated by conventional angiography after endovascular thrombectomy (EVT). However, whether these FDCT-detected occlusions are associated with tissue-level outcomes remains unclear. We investigated whether FDCT-augmented reperfusion grading better reflects tissue imaging outcomes than operator-assessed reperfusion grading in patients with ischaemic stroke. Patients and methods We retrospectively analysed EVT-treated patients with expanded thrombolysis in cerebral infarction (TICI) ≥ 2b who underwent post-interventional FDCT and follow-up MRI. DOT signs were defined as punctiform or tubular hyperdensities on FDCT. Final infarct volume (FIV) was segmented using follow-up DWI. Reperfusion status was categorised as incomplete (TICI 2b) or near-complete/complete (TICI 2c/3) based on FDCT-augmented TICI assessed by a core laboratory or operator-graded TICI.
Results
Among 200 patients, the median FIV was 20.0 mL (IQR, 5.9–74.6), and DOT signs were identified in 86 (43.0%). Operator-graded TICI classified 61 patients (30.5%) as having incomplete reperfusion, compared with 72 patients (36.0%) by FDCT-augmented TICI; 17 patients were reclassified. Compared with near-complete/complete reperfusion, incomplete reperfusion by FDCT-augmented TICI was associated with larger FIV (β = 24.0 mL; 95% CI, 3.6–44.4), whereas operator-defined incomplete reperfusion was not (β = 12.2 mL; 95% CI, −9.5 to 33.9). The model incorporating FDCT-augmented TICI explained slightly more variance in FIV than the model incorporating operator-graded TICI (adjusted R2 0.256 vs 0.239).
Conclusion
FDCT-augmented reperfusion assessment may provide additional tissue-relevant information after EVT by identifying residual vessel occlusions associated with larger FIV.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Comprehensive Strokology, Fujita Health University School of Medicine, Toyoake, Japan.
- Department of Neurosurgery, Fujita Health University School of Medicine, Toyoake, Japan.
- Department of Radiology, Fujita Health University Hospital, Toyoake, Japan.
ORCID-Profile: Junpei Koge
Förderung
- Japan Society for the Promotion of Science (JSPS) KAKENHI
Zitieren
APA
Koge, J., Hashimoto, T., Suyama, K., Tanaka, K., Kuwahara, K., Fujiwara, E., Kojima, D., Mase, T., Tanaka, S., Hyoudou, S., Naito, S., Ito, K., Hirose, Y., & Matsumoto, S. (2026). Refining reperfusion assessment with flat-panel detector CT: association with final infarct volume after endovascular thrombectomy. European Stroke Journal. https://doi.org/10.1093/esj/aakag104
Vancouver
Koge J, Hashimoto T, Suyama K, Tanaka K, Kuwahara K, Fujiwara E, et al. Refining reperfusion assessment with flat-panel detector CT: association with final infarct volume after endovascular thrombectomy. European Stroke Journal. 2026. doi:10.1093/esj/aakag104
BibTeX
@article{Koge2026,
author = {Koge, Junpei and Hashimoto, Tetsuya and Suyama, Kenichiro and Tanaka, Koji and Kuwahara, Kiyonori and Fujiwara, Eiji and Kojima, Daijiro and Mase, Tatsunori and Tanaka, Shiho and Hyoudou, Saki and Naito, Syouta and Ito, Katsuyoshi and Hirose, Yuichi and Matsumoto, Shoji},
title = {Refining reperfusion assessment with flat-panel detector CT: association with final infarct volume after endovascular thrombectomy},
journal = {European Stroke Journal},
year = {2026},
doi = {10.1093/esj/aakag104}
}