EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Left ventricular transmural pressure and ventilatory inefficiency during exercise in advanced heart failure

Barkin Kultursay iD, Seda Tanyeri Uzel, Murat Karacam, Seref Berk Tuncer, Azmican Kaya, Halit Eminoglu, Suleyman Cagan Efe, Gulumser Sevgin Halil, Cem Dogan, Deniz Mutlu iD, Mehmet Kaan Kirali, Rezzan Deniz Acar und 1 weitere

ESC Heart Failure · 2026

DOI: 10.1093/eschf/xvag247 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ESC Heart Failure, 2026. Verfasst von Barkin Kultursay und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Tunceli State Hospital, Cumhuriyet Mah. 552. Sokak No: 2, 62000 Tunceli/Merkez, Türkiye. Hauptthemen laut MEDLINE: Heart Failure, Ventricular Pressure, Ventricular Function, Left, Pulmonary Ventilation. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Baseline intracavitary haemodynamic measurements frequently demonstrate an inconsistent relationship with exertional performance. This may reflect an incomplete interpretation of left ventricular (LV) filling pressures. LV transmural pressure difference (ΔPTM = LV end-diastolic pressure [LVEDP]—right atrial pressure [RAP]) integrates LV filling pressure with right ventricular/pericardial constraint and may provide a composite representation of resting haemodynamic conditions. Ventilatory efficiency, assessed by the minute ventilation-carbon dioxide production (VE/VCO2) slope during cardiopulmonary exercise testing (CPET), is a leading representation of cardiopulmonary reserves and a powerful prognostic marker in heart failure (HF). Whether ΔPTM is associated with exercise ventilatory efficiency beyond conventional resting filling pressure measurements remains unclear.

Methods

We retrospectively studied 422 patients with advanced HF (LVEF ≤25%) who underwent right-heart catheterization and CPET. ΔPTM was analysed both continuously and by tertiles. The primary outcome was VE/VCO2 slope; peak VO2 was a secondary outcome. Bayesian multivariable regression models were adjusted using a directed acyclic graph-derived confounder set. Sensitivity analyses compared ΔPTM with LVEDP and RAP modelled individually and jointly.

Results

Among 422 patients (mean age 51.3 ± 10.8 years; 62 [14.7%] female), higher ΔPTM was independently associated with a lower VE/VCO2 slope (posterior mean β = −0.34 per mmHg; 95% credible interval [CrI] −0.58 to −0.11; 99.7% posterior probability of a negative association). Unadjusted VE/VCO2 slope decreased from 40.2 (31.7–67.1) in the lowest ΔPTM tertile to 34.9 (30.6–44.8) in the highest tertile (P = .029). The adjusted posterior predictive difference between the highest and lowest ΔPTM tertiles was −4.42 units (95% CrI −7.85 to −0.62). Following multivariable adjustment, ΔPTM showed no significant association with peak VO2 (posterior mean β = +0.06; 95% CrI −0.02 to +0.14). Neither LVEDP nor RAP, modelled individually or jointly, demonstrated independent associations with ventilatory efficiency.

Conclusion

Resting ΔPTM was inversely associated with the VE/VCO2 slope during exercise, whereas no independent association was observed with peak VO2. Compared with individual left- or right-sided filling pressures, ΔPTM provides a parsimonious summary of the balance between left-sided distending pressure and right-sided constraint associated with ventilatory efficiency in advanced HF.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart FailureVentricular PressureVentricular Function, LeftPulmonary VentilationHeart VentriclesExerciseExercise ToleranceStroke VolumeHumansRetrospective StudiesFemaleMaleExercise TestMiddle AgedOxygen ConsumptionCardiac Catheterization

Stichwörter der Autor:innen

Cardiopulmonary exercise testingHaemodynamicsHeart failureVentilatory efficiency

Autor:innen und Institutionen

  • Department of Cardiology, Tunceli State Hospital, Cumhuriyet Mah. 552. Sokak No: 2, 62000 Tunceli/Merkez, Türkiye.
  • Department of Cardiology, Kartal Kosuyolu High Specialization Education and Research Hospital, Istanbul, Turkiye.
  • Department of Cardiology, Bitlis State Hospital, Bitlis, Turkiye.
  • Department of Interventional Cardiology, Mount Sinai Hospital, New York City, NY, USA.
  • Department of Cardiovascular Surgery, Kartal Kosuyolu High Specialization Education and Research Hospital, Istanbul, Turkiye.
  • Department of Cardiology, Basaksehir Pine and Sakura City Hospital, Istanbul, Turkiye.

ORCID-Profile: Barkin Kultursay, Deniz Mutlu

Zitieren

APA

Kultursay, B., Tanyeri Uzel, S., Karacam, M., Tuncer, S. B., Kaya, A., Eminoglu, H., Efe, S. C., Halil, G. S., Dogan, C., Mutlu, D., Kirali, M. K., Acar, R. D., & Aslanger, E. (2026). Left ventricular transmural pressure and ventilatory inefficiency during exercise in advanced heart failure. ESC Heart Failure. https://doi.org/10.1093/eschf/xvag247

Vancouver

Kultursay B, Tanyeri Uzel S, Karacam M, Tuncer SB, Kaya A, Eminoglu H, et al. Left ventricular transmural pressure and ventilatory inefficiency during exercise in advanced heart failure. ESC Heart Failure. 2026. doi:10.1093/eschf/xvag247

BibTeX
@article{Kultursay2026,
  author = {Kultursay, Barkin and Tanyeri Uzel, Seda and Karacam, Murat and Tuncer, Seref Berk and Kaya, Azmican and Eminoglu, Halit and Efe, Suleyman Cagan and Halil, Gulumser Sevgin and Dogan, Cem and Mutlu, Deniz and Kirali, Mehmet Kaan and Acar, Rezzan Deniz and Aslanger, Emre},
  title = {Left ventricular transmural pressure and ventilatory inefficiency during exercise in advanced heart failure},
  journal = {ESC Heart Failure},
  year = {2026},
  doi = {10.1093/eschf/xvag247}
}