EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Bioimpedance-derived compartmental fluid status and prognosis in chronic heart failure

Jorge Montiel, Alicia Lucas, Pablo Peiró, Gonzalo Núñez, Miguel Lorenzo iD, Andrea Gasull, Gema Miñana iD, Anna Mollar, Enrique Santas, José Luis Górriz, Juan Sanchis iD, Julio Núñez und 1 weitere

ESC Heart Failure · 2026

DOI: 10.1093/eschf/xvag002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ESC Heart Failure, 2026. Verfasst von Jorge Montiel und 12 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Department, Hospital Clínico Universitario de Valencia, Avda. Blasco Ibáñez 17, Valencia 46010, Spain. Hauptthemen laut MEDLINE: Heart Failure, Electric Impedance, Body Fluids, Stroke Volume. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science, Innovation and Universities, CIBER Cardiovascular.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Novel bioimpedance analysis (BIA) devices may improve the precision of fluid overload assessment, potentially offering additional prognostic information beyond clinical parameters in patients with HF. This study aimed to evaluate the association between fluid overload indexes obtained with a novel bioelectrical impedance device (BioScan touch i8 IVF, MALTRON®) and the risk of cardiovascular events in ambulatory patients with HF.

Methods

Volume excess was assessed using BioScan Touch i8 IVF (MALTRON), which differentiates fluid distribution across body compartments. Volume-excess variables (total, intravascular, and tissue) were analysed both as quartiles (Q) and as continuous measures. Their independent associations with the composite of all-cause death or worsening HF were adjusted for established prognostic markers, including a clinical congestion score (CCS) and N-terminal pro-B-type natriuretic peptide.

Results

Among 386 ambulatory patients with stage C chronic HF, median total, intravascular, and tissue fluid excess were 1.3 L (Q1–Q3: 0.5, 2.3), 0.1 L (Q1–Q3: −0.1, 0.4), and 1.9 L (Q1–Q3: 1.1, 2.8), respectively. Total and tissue fluid excess had the strongest correlation with the CCS (Total fluid excess rho = 0.31; P < .001, tissue fluid excess rho = 0.33; P < .001). In adjusted analyses, patients in the highest quartile had significantly higher risk of the composite outcome compared with Q1: total fluid excess hazard ratio (HR) 2.11 [95% confidence interval (CI) 1.21–4.05, P = .010], intravascular fluid excess HR 2.16 (1.19–3.90, P = .011), and tissue fluid excess HR 2.81 (1.49–5.32, P = .001).

Conclusion

Compartment-specific estimates of fluid overload obtained with the BioScan Touch i8 IVF were independently associated with adverse outcomes in ambulatory patients with chronic HF, beyond NT-proBNP and clinical surrogates of congestion. These findings support the potential role of BIA-derived indexes, particularly tissue fluid excess, as complementary tools for risk stratification in this population.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart FailureElectric ImpedanceBody FluidsStroke VolumeBody CompositionHumansPrognosisFemaleMaleChronic DiseaseAgedMiddle AgedFollow-Up Studies

Stichwörter der Autor:innen

Bioimpedance analysisChronic heart failureCongestion

Autor:innen und Institutionen

  • Cardiology Department, Hospital Clínico Universitario de Valencia, Avda. Blasco Ibáñez 17, Valencia 46010, Spain.
  • Internal Medicine Department, Hospital Clínico Universitario de Valencia, Valencia, Spain.
  • Department of Medicine, Universitat de València, Valencia, Spain.
  • INCLIVA Biomedical Research Institute, Valencia, Spain.
  • Centro de Investigación Biomédica en Red-Cardiovascular (CIBER-CV), Madrid, Spain.
  • Nephrology Department, Hospital Clínico Universitario de Valencia, Valencia, Spain.

ORCID-Profile: Miguel Lorenzo, Gema Miñana, Juan Sanchis, Rafael de la Espriella

Förderung

  • Ministry of Science, Innovation and Universities
  • CIBER Cardiovascular

Zitieren

APA

Montiel, J., Lucas, A., Peiró, P., Núñez, G., Lorenzo, M., Gasull, A., Miñana, G., Mollar, A., Santas, E., Górriz, J. L., Sanchis, J., Núñez, J., & de la Espriella, R. (2026). Bioimpedance-derived compartmental fluid status and prognosis in chronic heart failure. ESC Heart Failure. https://doi.org/10.1093/eschf/xvag002

Vancouver

Montiel J, Lucas A, Peiró P, Núñez G, Lorenzo M, Gasull A, et al. Bioimpedance-derived compartmental fluid status and prognosis in chronic heart failure. ESC Heart Failure. 2026. doi:10.1093/eschf/xvag002

BibTeX
@article{Montiel2026,
  author = {Montiel, Jorge and Lucas, Alicia and Peiró, Pablo and Núñez, Gonzalo and Lorenzo, Miguel and Gasull, Andrea and Miñana, Gema and Mollar, Anna and Santas, Enrique and Górriz, José Luis and Sanchis, Juan and Núñez, Julio and de la Espriella, Rafael},
  title = {Bioimpedance-derived compartmental fluid status and prognosis in chronic heart failure},
  journal = {ESC Heart Failure},
  year = {2026},
  doi = {10.1093/eschf/xvag002}
}
Kostenlos starten →