Failure rates of 958 interradicular mini-screws for maxillary total arch distalization following a well-established insertion protocol
European Journal of Orthodontics · 02.06.2026 · 48 (4)
DOI: 10.1093/ejo/cjag051 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift European Journal of Orthodontics, online erschienen am 30.06.2026. Verfasst von Lara Bettenhäuser-Hartung und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Hannover Medical School, Carl-Neuberg-Straße 1, 30625 Hannover, Germany. Hauptthemen laut MEDLINE: Orthodontic Anchorage Procedures, Maxilla, Bone Screws, Tooth Movement Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objectives
Maxillary Total Arch Distalization (MTAD) with interradicular mini-screws (MSs) in combination with Completely Customized Lingual Appliances (CCLAs) is an effective concept for Class II correction in adolescents and adults which does not require any additional supraconstructions. The aim of this study was to investigate the failure rates of MSs after strictly following a defined insertion protocol. Patients and methods From November 2015 to August 2025, a total of 958 interradicular MSs were inserted in the maxilla for MTAD in combination with a CCLA in one orthodontic specialist practice. The surgical procedures were performed by 8 different clinicians (6 orthodontist specialists/2 postgraduate students in orthodontics) on 283 patients (female: 199/male: 84) with an average age of 27.6 years, ±13.3. Premature loss was defined as any instance in which a MS required removal due to mobility or was lost spontaneously on a yes/no basis.
Results
Of the 958 interradicular mini-screws, 14 (1.5%) failed before schedule (palatal 13/buccal 1). No significant influence of the experience level of the clinicians (P = 0.394) on the mini-screw loss rate was observed. The highest loss rate was observed in the patients > 45 age group.
Limitations
One limitation is the retrospective study design, but no patient meeting the inclusion criteria was excluded for any reason.
Conclusions
Interradicular mini-screws used as temporary anchorage devices for maxillary total arch distalization can exhibit comparably low failure rates (1.5%) to those placed in the anterior palate, provided that a well-established clinical protocol is strictly followed.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthodontics, Hannover Medical School, Carl-Neuberg-Straße 1, 30625 Hannover, Germany.
- Private Practice, Lindenstraße 44, 49152 Bad Essen, Germany.
- Department of Orthodontics and Dentofacial Orthopedics, University of Bern, Freiburgstrasse 7, CH-3010 Bern, Switzerland.
- Department of Orthodontics, University of Münster, Albert-Schweitzer-Campus 1, 48149 Münster, Germany.
ORCID-Profile: Lara Bettenhäuser-Hartung, Frauke Beyling, Rainer Schwestka-Polly, Christos Katsaros, Jonas Q Schmid
Zitieren
APA
Bettenhäuser-Hartung, L., Beyling, F., Schwestka-Polly, R., Katsaros, C., & Schmid, J. Q. (2026). Failure rates of 958 interradicular mini-screws for maxillary total arch distalization following a well-established insertion protocol. European Journal of Orthodontics, 48(4). https://doi.org/10.1093/ejo/cjag051
Vancouver
Bettenhäuser-Hartung L, Beyling F, Schwestka-Polly R, Katsaros C, Schmid JQ. Failure rates of 958 interradicular mini-screws for maxillary total arch distalization following a well-established insertion protocol. European Journal of Orthodontics. 2026;48(4). doi:10.1093/ejo/cjag051
BibTeX
@article{BettenhuserHartung2026,
author = {Bettenhäuser-Hartung, Lara and Beyling, Frauke and Schwestka-Polly, Rainer and Katsaros, Christos and Schmid, Jonas Q},
title = {Failure rates of 958 interradicular mini-screws for maxillary total arch distalization following a well-established insertion protocol},
journal = {European Journal of Orthodontics},
year = {2026},
volume = {48},
number = {4},
doi = {10.1093/ejo/cjag051}
}
EUVIMED