Center of resistance of maxillary canines: a 3D computational model for orthodontic applications
European Journal of Orthodontics · 2025
DOI: 10.1093/ejo/cjaf097 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Orthodontics, 2025. Verfasst von Vaibhav Gandhi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Growth and Development, University of Nebraska Medical Center, 4000 East Campus Loop South, Lincoln, NE 68583, USA. Hauptthemen laut MEDLINE: Cuspid, Imaging, Three-Dimensional, Tooth Movement Techniques, Computer Simulation. Die Arbeit nennt 41 Literaturangaben.
Abstract (Originalsprache)
Introduction
The center of resistance (CRES) is regarded as the fundamental reference point for predictable tooth movement. Only a handful of studies have evaluated the CRES of a maxillary canine; however, most had a low sample size, used idealized models, or involved 2D analysis. The objectives of this study were to determine the 3D location of the CRES of maxillary canines, evaluate its variability, and investigate the effects of applying orthodontic load from two directions on the location of the CRES.
Methods
Cone-beam computed tomography (CBCT) scans of 50 maxillary molars from 25 patients (mean age, 20.8 ± 8.7 years) were used. CBCT images were manipulated to extract 3D biological structures via segmentation. The segmented structures were cleaned and converted into virtual mesh models made of tetrahedral triangles having a maximum edge length of 1 mm. The block, which included the canines and periodontal ligament, consisted of a mean of 4863 ± 1544 nodes and 23 501 ± 8512 tetrahedral elements. Specialized software was used to preprocess the models to create an assembly and assign material properties, interaction conditions, boundary conditions, and load applications. Specific loads were applied, and custom-designed algorithms were used to analyze the stress and strain to locate the CRES. The CRES was measured in relation to the geometric center (R point) of the buccal surface of the canine.
Results
The average location of the CRES for the maxillary canine was 3.91 ± 1.33 mm palatal, 6.52 ± 1.24 mm distal, and 8.37 ± 2.39 mm gingival relative to R. None of the canines showed a convergence of the CRES at a single point, but the difference was not significant (P > .01). In the anteroposterior and the vertical planes, the CRES showed significant association with root divergence (P < .01).
Conclusion
The canine CRES was found distal, apical, and palatal to the R point. It was located at 61.5% of the total tooth length or 17.2 mm measured from the cusp tip. Anatomic variation and orientation have a significant impact on the 3D localization of the CRES.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Growth and Development, University of Nebraska Medical Center, 4000 East Campus Loop South, Lincoln, NE 68583, USA.
- Division of Orthodontics, University of Florida, Gainesville, FL 32610, USA.
- Adjunct Professor, University of Jordan, Amman, Jordan.
- Department of Mechanical Engineering, Biomedical Engineering, Mathematics, University of Connecticut, Storrs, CT 06269, USA.
- Division of Orthodontics, Department of Craniofacial Sciences, University of Connecticut Health Center, Farmington, CT 06030, USA.
ORCID-Profile: Vaibhav Gandhi, Sarah Abu Arqub
Zitieren
APA
Gandhi, V., Abu Arqub, S., Pierce, D., Yadav, S., & Upadhyay, M. (2025). Center of resistance of maxillary canines: a 3D computational model for orthodontic applications. European Journal of Orthodontics. https://doi.org/10.1093/ejo/cjaf097
Vancouver
Gandhi V, Abu Arqub S, Pierce D, Yadav S, Upadhyay M. Center of resistance of maxillary canines: a 3D computational model for orthodontic applications. European Journal of Orthodontics. 2025. doi:10.1093/ejo/cjaf097
BibTeX
@article{Gandhi2025,
author = {Gandhi, Vaibhav and Abu Arqub, Sarah and Pierce, David and Yadav, Sumit and Upadhyay, Madhur},
title = {Center of resistance of maxillary canines: a 3D computational model for orthodontic applications},
journal = {European Journal of Orthodontics},
year = {2025},
doi = {10.1093/ejo/cjaf097}
}
EUVIMED