Effects of intraoral aging on mechanical properties of directly printed aligners vs. thermoformed aligners: an in vivo prospective investigation

Babak Sayahpour, Spiros Zinelis, Georgios Polychronis, Theodore Eliades iD, Malcolm Goteni, Stefan Kopp, Sara Eslami iD

European Journal of Orthodontics · 01.01.2024 · 46 (1)

DOI: 10.1093/ejo/cjad063 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Orthodontics, online erschienen am 04.11.2023. Verfasst von Babak Sayahpour und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Johann-Wolfgang Goethe University, Theodor-Stern-Kai 7, 60596 Frankfurt am Main, Germany. Hauptthemen laut MEDLINE: Mechanical Phenomena, Polyurethanes. Die Arbeit wurde bisher 41-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The objective of this study was to examine the impact of intraoral aging on the mechanical properties of directly printed aligners (DPA) compared to thermoformed aligners (TA). Materials and methods This prospective in vivo experiment included three types of aligners: DPAs (group DP) fabricated from Tera Harz TC-85 DAC resin (Graphy, Korea), TA (group INV) made from a polyurethane-based polymer (Align Technology, Inc., CA, USA), and TA (group DUR) made from polyethylene glycol terephthalate based polymer (Scheu-Dental, Germany). Each group was categorized into retrieved (Clin) and unused aligners (Ctr). Thirty patients (10 per group) wore the aligners for 7 days, thereby generating the retrieved samples. Thirty unused aligners were employed as control samples. The following mechanical properties were determined: Martens Hardness (HM), indentation modulus (EIT), elastic index (ηIT), and indentation relaxation (RIT). Intergroup comparisons were conducted using ANOVA/Kruskal–Wallis test. Comparisons between retrieved and control samples were done using Wilcoxon–Mann–Whitney-U/Student’s t-test/Welch’s test.

Results

Statistically significant differences between the groups were found for both control and used samples (P < .001). Pairwise comparisons also revealed significant differences between the samples. The mechanical properties did not differ significantly between unused and retrieved INV- and DUR-aligners, whereas for DP-aligners significant differences for ηIT and RIT were found following intraoral service (P-values .012 and .002, respectively).

Conclusions

Group DUR showed generally more favorable mechanical properties compared to DP and INV. The much higher RIT and EIT in DP aligners suggest their higher rigidity and force decay, which could compromise their clinical efficacy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mechanical PhenomenaPolyurethanesHumansProspective StudiesHardnessPolyethylene GlycolsMaterials Testing

Stichwörter der Autor:innen

3D printingInvisalignagingclear orthodontic alignersdirect printed alignersmechanical properties

Substanzen

PolyurethanesPolyethylene Glycols

Autor:innen und Institutionen

  • Department of Orthodontics, Johann-Wolfgang Goethe University, Theodor-Stern-Kai 7, 60596 Frankfurt am Main, Germany.
  • Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, 11527 Athens, Greece.
  • Clinic of Orthodontics and Pediatric Dentistry Center of Dental Medicine, University of Zurich, Zurich 8032, Switzerland.
  • Private Orthodontic Practice, Grafenberger Alle 57, 40237 Duesseldorf, Germany.

ORCID-Profile: Theodore Eliades, Sara Eslami

Zitieren

APA

Sayahpour, B., Zinelis, S., Polychronis, G., Eliades, T., Goteni, M., Kopp, S., & Eslami, S. (2024). Effects of intraoral aging on mechanical properties of directly printed aligners vs. thermoformed aligners: an in vivo prospective investigation. European Journal of Orthodontics, 46(1). https://doi.org/10.1093/ejo/cjad063

Vancouver

Sayahpour B, Zinelis S, Polychronis G, Eliades T, Goteni M, Kopp S, et al. Effects of intraoral aging on mechanical properties of directly printed aligners vs. thermoformed aligners: an in vivo prospective investigation. European Journal of Orthodontics. 2024;46(1). doi:10.1093/ejo/cjad063

BibTeX
@article{Sayahpour2024,
  author = {Sayahpour, Babak and Zinelis, Spiros and Polychronis, Georgios and Eliades, Theodore and Goteni, Malcolm and Kopp, Stefan and Eslami, Sara},
  title = {Effects of intraoral aging on mechanical properties of directly printed aligners vs. thermoformed aligners: an in vivo prospective investigation},
  journal = {European Journal of Orthodontics},
  year = {2024},
  volume = {46},
  number = {1},
  doi = {10.1093/ejo/cjad063}
}
Kostenlos starten →