EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyse

Diagnostic accuracy of N-terminal pro-B type natriuretic peptide thresholds in dyspnoeic patients in the emergency department according to patients’ characteristics: a systematic review and meta-analysis

Guillaume Baudry iD, Luca Monzo, Vincent Faivre, Zohra Lamiral, Kevin Duarte, James L Januzzi, Antony Bayes-Genis, Nicolas Girerd

European Journal of Heart Failure · 17.10.2026

DOI: 10.1093/ejhf/xuag314 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift European Journal of Heart Failure, online erschienen am 17.10.2026. Verfasst von Guillaume Baudry und 7 weiteren Autor:innen. Beteiligte Einrichtung: Université de Lorraine, INSERM, Centre d'Investigation Clinique Plurithématique 1433, Inserm U1116, CHRU de Nancy and F-CRIN INI-CRCT, Nancy, France. Die Arbeit nennt 49 Literaturangaben. Gefördert von: France 2030 program ‘Initiative d’Excellence Lorraine’, France 2030 ENACT AI Cluster, French National Research Agency.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Concentrations of N-terminal pro-B type natriuretic peptide (NT-proBNP) are central to acute heart failure (AHF) diagnosis in dyspnoeic emergency departments (EDs) patients, but optimal thresholds remain uncertain. This study aimed to evaluate the diagnostic accuracy of various NT-proBNP thresholds for AHF, across the general population and in key subgroups (chronic kidney disease and obesity).

Methods

A systematic review and meta-analysis were conducted, including studies published up to 28 August 2025, which reported the diagnostic performance of NT-proBNP thresholds for AHF in dyspnoeic ED patients.

Results

The analysis included 31 studies comprising 26 948 patients. To exclude AHF, a fixed threshold of ≤300 ng/L yielded an area under the receiver operating characteristic curve (AUC) of 0.73 (0.69–0.77), with high sensitivity of 97.9% (96.9–98.5) and lower specificity of 46.2% (36.4–56.2); the negative predictive value of this threshold was 97.0% (96.5–97.4). Age-dependent thresholds (≥450 ng/L for patients aged <50 years, ≥900 ng/L for those aged 50–75 years, and ≥1800 ng/L for those aged ≥75 years), evaluated in 14 410 patients, achieved an AUC of 0.84 (0.83–0.85) with a more favourable balance between a sensitivity of 85.9% (85.0–86.7) and a specificity of 82.0% (81.2–82.9). In patients with chronic kidney disease (n = 2271), all fixed thresholds yielded AUC <0.80; age-dependent thresholds showed an AUC of 0.77 (0.75–0.78) with a specificity of 62.6% (59.4–65.7). In patients with obesity (body mass index ≥ 30 kg/m2), only age-dependent thresholds were assessed in 3562 patients; AUC was 0.82 (0.81–0.84), and sensitivity was 81.2% (79.2–83.1), broadly comparable to the overall population.

Conclusion

A threshold ≤300 ng/L provides excellent rule-out performance for AHF, while age-dependent NT-proBNP thresholds offer superior diagnostic performance for ruling in AHF in the ED compared to fixed thresholds and demonstrate consistent accuracy across subgroups. However, evidence in patients with chronic kidney disease and obesity remains limited, both in terms of sample size and the range of thresholds evaluated.

Schlagwörter

Stichwörter der Autor:innen

DyspneaEmergency ServiceHeart FailureHospitalMeta-AnalysisNatriuretic PeptidesSensitivity and Specificity

Autor:innen und Institutionen

  • Université de Lorraine, INSERM, Centre d'Investigation Clinique Plurithématique 1433, Inserm U1116, CHRU de Nancy and F-CRIN INI-CRCT, Nancy, France.
  • REICATRA, Recherche et Enseignement en IC Avancée, Transplantation, Assistance , Vandœuvre-lès-Nancy, France.
  • Heart and Vascular Institute, Mass General Brigham, Boston, Massachusetts, USA.
  • Harvard Medical School, Boston, Massachusetts, USA.
  • Baim Institute for Clinical Research, Brookline, Massachusetts, USA.
  • Heart Institute, Hospital Universitari Germans Trias i Pujol, CIBERCV, Badalona, Spain.

ORCID-Profile: Guillaume Baudry

Förderung

  • France 2030 program ‘Initiative d’Excellence Lorraine’
  • France 2030 ENACT AI Cluster
  • French National Research Agency
  • Fédération Française de Cardiologie
  • Société Française de Cardiologie

Zitieren

APA

Baudry, G., Monzo, L., Faivre, V., Lamiral, Z., Duarte, K., Januzzi, J. L., Bayes-Genis, A., & Girerd, N. (2026). Diagnostic accuracy of N-terminal pro-B type natriuretic peptide thresholds in dyspnoeic patients in the emergency department according to patients’ characteristics: a systematic review and meta-analysis. European Journal of Heart Failure. https://doi.org/10.1093/ejhf/xuag314

Vancouver

Baudry G, Monzo L, Faivre V, Lamiral Z, Duarte K, Januzzi JL, et al. Diagnostic accuracy of N-terminal pro-B type natriuretic peptide thresholds in dyspnoeic patients in the emergency department according to patients’ characteristics: a systematic review and meta-analysis. European Journal of Heart Failure. 2026. doi:10.1093/ejhf/xuag314

BibTeX
@article{Baudry2026,
  author = {Baudry, Guillaume and Monzo, Luca and Faivre, Vincent and Lamiral, Zohra and Duarte, Kevin and Januzzi, James L and Bayes-Genis, Antony and Girerd, Nicolas},
  title = {Diagnostic accuracy of N-terminal pro-B type natriuretic peptide thresholds in dyspnoeic patients in the emergency department according to patients’ characteristics: a systematic review and meta-analysis},
  journal = {European Journal of Heart Failure},
  year = {2026},
  doi = {10.1093/ejhf/xuag314}
}
Kostenlos starten →