Head-to-head comparison of real-time three-dimensional transthoracic echocardiography with transthoracic and transesophageal two-dimensional contrast echocardiography for the detection of patent foramen ovale
European Journal of Echocardiography · 01.04.2010 · 11 (3) · 245-249
DOI: 10.1093/ejechocard/jep195 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Journal of Echocardiography, online erschienen am 28.11.2009. Verfasst von Ines Monte und 3 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Echocardiography, Echo Department, Policlinic of University, via S.Sofia 78-95125, Catania, Italy. inemonte@unict.it. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
AIMS: To assess the incremental value of real-time three-dimensional echocardiography (RT-3DTE) over contrast transthoracic echocardiography (TTE), compared with contrast transesophageal echocardiography (TEE) in the identification of patent foramen ovale (PFO). METHODS AND RESULTS: Eighty-one consecutive patients with history of migraine headache (MH) or unexplained cerebrovascular events (CE) were examined using RT-3DTE, contrast TTE, and contrast TEE in sequence. Feasibility of RT-3DE in patients with MH and CE was 98 and 91%, respectively. Mean time for 3D colour data set acquisition was 9 +/- 5 min. PFO was diagnosed using contrast TEE in 36 patients (overall prevalence = 44%). Diagnostic accuracy of RT-3DE was significantly higher than that of contrast TTE: sensitivity 83 vs. 44%, P < 0.001; specificity 100 vs. 100%, P7 = NS; positive predictive value 100 vs. 100%, P = NS; negative predictive value 88 vs. 69%, P < 0.01; accuracy 93 vs. 75%, P < 0.003. Five of the six patients in whom RT-3DTE did not identify PFOs showed a defect diameter smaller than 2 mm. CONCLUSION: RT-3DTE is a feasible, accurate, and reproducible technique to detect PFO without the need of saline contrast injection. Its accuracy is superior to contrast 2D TTE and close to that of contrast TEE.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Clinical Echocardiography, Echo Department, Policlinic of University, via S.Sofia 78-95125, Catania, Italy. inemonte@unict.it
Zitieren
APA
Monte, I., Grasso, S., Licciardi, S., & Badano, L. P. (2010). Head-to-head comparison of real-time three-dimensional transthoracic echocardiography with transthoracic and transesophageal two-dimensional contrast echocardiography for the detection of patent foramen ovale. European Journal of Echocardiography, 11(3), 245-249. https://doi.org/10.1093/ejechocard/jep195
Vancouver
Monte I, Grasso S, Licciardi S, Badano LP. Head-to-head comparison of real-time three-dimensional transthoracic echocardiography with transthoracic and transesophageal two-dimensional contrast echocardiography for the detection of patent foramen ovale. European Journal of Echocardiography. 2010;11(3):245-249. doi:10.1093/ejechocard/jep195
BibTeX
@article{Monte2010,
author = {Monte, Ines and Grasso, Stefania and Licciardi, Salvatore and Badano, Luigi P},
title = {Head-to-head comparison of real-time three-dimensional transthoracic echocardiography with transthoracic and transesophageal two-dimensional contrast echocardiography for the detection of patent foramen ovale},
journal = {European Journal of Echocardiography},
year = {2010},
volume = {11},
number = {3},
pages = {245--249},
doi = {10.1093/ejechocard/jep195}
}
EUVIMED