Electrosurgical Septotomy Across the Full Spectrum of Aortic Dissection
European Journal of Cardio-Thoracic Surgery · 02.11.2026 · 68 (11-12)
DOI: 10.1093/ejcts/ezag246 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Cardio-Thoracic Surgery, online erschienen am 21.10.2026. Verfasst von Gabriel Weiss und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac and Vascular Surgery, Klinik Floridsdorf, Vienna Health Association (Wiener Gesundheitsverbund), Vienna 1210, Austria. Hauptthemen laut MEDLINE: Electrosurgery, Aortic Dissection. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
Objectives
Transcatheter electrosurgical septotomy divides the dissection membrane to reconstitute a single aortic lumen. Reported experience is largely confined to chronic post-dissection aneurysms. We assessed the technique across the full spectrum of descending aortic dissection, including stand-alone treatment of malperfusion.
Methods
A retrospective intention-to-treat analysis of 21 consecutive patients scheduled for septotomy between June 2022 and May 2026. The membrane was crossed by needle re-entry and divided with an electrified through-and-through guidewire at 40-60 W under fluoroscopy, without routine intravascular ultrasound or image fusion. A perfused-lumen index (perfused lumen divided by total aortic diameter) was measured before and after the procedure.
Results
Septotomy was performed in 20 of 21 patients (technical success 95% on an intention-to-treat basis). Indications were landing-zone preparation (57%), malperfusion (33%), preparation for open repair, and true-lumen collapse. Malperfusion resolved in all 7 patients treated for that indication, and the perfused-lumen index rose from a median of 0.16 to 0.98 (18 patients, P < .001). There was no stroke, spinal cord ischaemia, or retrograde type A dissection. Thirty-day, in-hospital, and overall mortality were 10%, 14%, and 19%, respectively, with 1 fatal delayed aortic rupture and no intraprocedural death. Three unplanned reinterventions occurred; median follow-up was 5.1 months.
Conclusions
Electrosurgical septotomy was feasible across the full spectrum of aortic dissection and, in selected patients, as stand-alone treatment for malperfusion, using standard electrosurgical equipment. Given the small, heterogeneous cohort and short follow-up, these findings demonstrate feasibility rather than durability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiac and Vascular Surgery, Klinik Floridsdorf, Vienna Health Association (Wiener Gesundheitsverbund), Vienna 1210, Austria.
- Karl Landsteiner Institute for Cardiac and Vascular Surgical Research, Department of Cardiac and Vascular Surgery, Klinik Floridsdorf, Vienna 1210, Austria.
- Faculty of Medicine, Sigmund Freud University Vienna, Vienna 1020, Austria.
- Department of Interventional Radiology, Klinik Floridsdorf, Vienna 1210, Austria.
ORCID-Profile: Gabriel Weiss, Martin Grabenwöger
Zitieren
APA
Weiss, G., Trnka, H., Tauber, S., Manville, E., Arnold, Z., Winkler, B., Folkmann, S., & Grabenwöger, M. (2026). Electrosurgical Septotomy Across the Full Spectrum of Aortic Dissection. European Journal of Cardio-Thoracic Surgery, 68(11-12). https://doi.org/10.1093/ejcts/ezag246
Vancouver
Weiss G, Trnka H, Tauber S, Manville E, Arnold Z, Winkler B, et al. Electrosurgical Septotomy Across the Full Spectrum of Aortic Dissection. European Journal of Cardio-Thoracic Surgery. 2026;68(11-12). doi:10.1093/ejcts/ezag246
BibTeX
@article{Weiss2026,
author = {Weiss, Gabriel and Trnka, Hubert and Tauber, Sebastian and Manville, Emely and Arnold, Zsuzsanna and Winkler, Bernhard and Folkmann, Sandra and Grabenwöger, Martin},
title = {Electrosurgical Septotomy Across the Full Spectrum of Aortic Dissection},
journal = {European Journal of Cardio-Thoracic Surgery},
year = {2026},
volume = {68},
number = {11-12},
doi = {10.1093/ejcts/ezag246}
}
EUVIMED