EUVIMEDEUVIMED entdecken
Crossref

Electrosurgical Septotomy Across the Full Spectrum of Aortic Dissection

Gabriel Weiss iD, Hubert Trnka, Sebastian Tauber, Emely Manville, Zsuzsanna Arnold, Bernhard Winkler, Sandra Folkmann, Martin Grabenwöger iD

European Journal of Cardio-Thoracic Surgery · 02.11.2026 · 68 (11-12)

DOI: 10.1093/ejcts/ezag246 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Cardio-Thoracic Surgery, online erschienen am 21.10.2026. Verfasst von Gabriel Weiss und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac and Vascular Surgery, Klinik Floridsdorf, Vienna Health Association (Wiener Gesundheitsverbund), Vienna 1210, Austria. Hauptthemen laut MEDLINE: Electrosurgery, Aortic Dissection. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Transcatheter electrosurgical septotomy divides the dissection membrane to reconstitute a single aortic lumen. Reported experience is largely confined to chronic post-dissection aneurysms. We assessed the technique across the full spectrum of descending aortic dissection, including stand-alone treatment of malperfusion.

Methods

A retrospective intention-to-treat analysis of 21 consecutive patients scheduled for septotomy between June 2022 and May 2026. The membrane was crossed by needle re-entry and divided with an electrified through-and-through guidewire at 40-60 W under fluoroscopy, without routine intravascular ultrasound or image fusion. A perfused-lumen index (perfused lumen divided by total aortic diameter) was measured before and after the procedure.

Results

Septotomy was performed in 20 of 21 patients (technical success 95% on an intention-to-treat basis). Indications were landing-zone preparation (57%), malperfusion (33%), preparation for open repair, and true-lumen collapse. Malperfusion resolved in all 7 patients treated for that indication, and the perfused-lumen index rose from a median of 0.16 to 0.98 (18 patients, P < .001). There was no stroke, spinal cord ischaemia, or retrograde type A dissection. Thirty-day, in-hospital, and overall mortality were 10%, 14%, and 19%, respectively, with 1 fatal delayed aortic rupture and no intraprocedural death. Three unplanned reinterventions occurred; median follow-up was 5.1 months.

Conclusions

Electrosurgical septotomy was feasible across the full spectrum of aortic dissection and, in selected patients, as stand-alone treatment for malperfusion, using standard electrosurgical equipment. Given the small, heterogeneous cohort and short follow-up, these findings demonstrate feasibility rather than durability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrosurgeryAortic DissectionHumansRetrospective StudiesFemaleMaleMiddle AgedDissection, Thoracic AortaAgedTreatment Outcome

Stichwörter der Autor:innen

aortic dissectionelectrosurgical septotomyendovascular repairlanding zonemalperfusiontrue-lumen expansion

Autor:innen und Institutionen

  • Department of Cardiac and Vascular Surgery, Klinik Floridsdorf, Vienna Health Association (Wiener Gesundheitsverbund), Vienna 1210, Austria.
  • Karl Landsteiner Institute for Cardiac and Vascular Surgical Research, Department of Cardiac and Vascular Surgery, Klinik Floridsdorf, Vienna 1210, Austria.
  • Faculty of Medicine, Sigmund Freud University Vienna, Vienna 1020, Austria.
  • Department of Interventional Radiology, Klinik Floridsdorf, Vienna 1210, Austria.

ORCID-Profile: Gabriel Weiss, Martin Grabenwöger

Zitieren

APA

Weiss, G., Trnka, H., Tauber, S., Manville, E., Arnold, Z., Winkler, B., Folkmann, S., & Grabenwöger, M. (2026). Electrosurgical Septotomy Across the Full Spectrum of Aortic Dissection. European Journal of Cardio-Thoracic Surgery, 68(11-12). https://doi.org/10.1093/ejcts/ezag246

Vancouver

Weiss G, Trnka H, Tauber S, Manville E, Arnold Z, Winkler B, et al. Electrosurgical Septotomy Across the Full Spectrum of Aortic Dissection. European Journal of Cardio-Thoracic Surgery. 2026;68(11-12). doi:10.1093/ejcts/ezag246

BibTeX
@article{Weiss2026,
  author = {Weiss, Gabriel and Trnka, Hubert and Tauber, Sebastian and Manville, Emely and Arnold, Zsuzsanna and Winkler, Bernhard and Folkmann, Sandra and Grabenwöger, Martin},
  title = {Electrosurgical Septotomy Across the Full Spectrum of Aortic Dissection},
  journal = {European Journal of Cardio-Thoracic Surgery},
  year = {2026},
  volume = {68},
  number = {11-12},
  doi = {10.1093/ejcts/ezag246}
}
Kostenlos starten →