Prognostic Value of 18Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Type A Aortic Intramural Haematoma
European Journal of Cardio-Thoracic Surgery · 2025
DOI: 10.1093/ejcts/ezaf261 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Cardio-Thoracic Surgery, 2025. Verfasst von Tianyu Chen und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Scienc…. Hauptthemen laut MEDLINE: Fluorodeoxyglucose F18, Hematoma, Positron Emission Tomography Computed Tomography, Aortic Diseases. Die Arbeit nennt 19 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Planning Project of Guangdong Province, China.
Abstract (Originalsprache)
Objectives
In this study, we aimed to assess 18fluorodeoxyglucose (18F-FDG) uptake in patients with type A aortic intramural haematoma (IMH) to establish its association with disease progression.
Methods
Patients with type A IMH receiving medical management were included. After the patient agreed to participate, 18F-FDG PET/CT was performed. The aortic 18F-FDG uptake was measured in standardized uptake value (SUV). The primary outcome was disease progression, which was defined as a condition requiring aortic intervention. The median follow-up was calculated by the inverse Kaplan-Meier method.
Results
A total of 32 patients were included in this study. During a median follow-up of 28.3 months (95% CI, 4.8-51.7), 14 events occurred in 14 patients (43.8%). Patients with disease progression had significantly higher SUVmax compared to the stable group (4.9 [SD:1.1] vs 3.5 [SD:1.0], P = .001). ROC curve analysis revealed that an SUVmax cut-off of 4.25 had a sensitivity of 78.6% and specificity of 77.8% for predicting disease progression, with an area under the curve (AUC) of 0.806 (95% CI, 0.653-0.958). The 2-year progression-free survival rates for the SUVmax increased (>4.25) and non-increased (≤4.25) were 20.7% and 75.0% (P = .019), respectively.
Conclusions
Increased aortic 18F-FDG uptake was associated with high risk for adverse aortic events in type A IMH. The SUVmax of 18F-FDG should be considered in the risk stratification and management of these patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiovascular Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Southern Medical University, Guangzhou 510080, P.R. China.
- Department of Nuclear Medicine, PET Center, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Southern Medical University, Guangzhou 510080, P.R. China.
Förderung
- National Natural Science Foundation of China
- Science and Technology Planning Project of Guangdong Province, China
Zitieren
APA
Chen, T., Yuan, H., Qiu, H., Jiang, L., Wu, J., Yang, J., Zhou, K., Sun, T., Zhuang, J., & Chen, Z. (2025). Prognostic Value of 18Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Type A Aortic Intramural Haematoma. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1093/ejcts/ezaf261
Vancouver
Chen T, Yuan H, Qiu H, Jiang L, Wu J, Yang J, et al. Prognostic Value of 18Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Type A Aortic Intramural Haematoma. European Journal of Cardio-Thoracic Surgery. 2025. doi:10.1093/ejcts/ezaf261
BibTeX
@article{Chen2025,
author = {Chen, Tianyu and Yuan, Hui and Qiu, Hailong and Jiang, Lei and Wu, Jinlin and Yang, Jue and Zhou, Kan and Sun, Tucheng and Zhuang, Jian and Chen, Zerui},
title = {Prognostic Value of 18Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Type A Aortic Intramural Haematoma},
journal = {European Journal of Cardio-Thoracic Surgery},
year = {2025},
doi = {10.1093/ejcts/ezaf261}
}
EUVIMED