EUVIMEDEUVIMED entdecken
Multizentrische StudieValidierungsstudieBeobachtungsstudie

External Validation of Mortality Prediction Models in Japanese Transcatheter Aortic Valve Replacement Registry

Ryo Shibata iD, Tomotsugu Seki iD, Yuki Takeda, Takuma Iwaya, Eisuke Kataoka, Tatsuya Kitada, Motoyoshi Takahara, Ryotaro Tani, Shunsuke Nakamura, Tomotaka Fujimoto iD, Masaki Yashige iD, Kazuaki Takamatsu und 8 weitere

European Journal of Cardio-Thoracic Surgery · 2025

DOI: 10.1093/ejcts/ezaf227 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift European Journal of Cardio-Thoracic Surgery, 2025. Verfasst von Ryo Shibata und 19 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Kyoto Prefectural University of Medicine, Kyoto, 602-8566, Japan. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Registries, Aortic Valve Stenosis. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Mortality prediction models (MPMs) play a crucial role in risk assessment for transcatheter aortic valve replacement (TAVR), but their external validity in Japanese patients remains unclear. This study evaluated the performance of existing short-term (30-day) and long-term (1-year) MPMs with Japanese TAVR patients.

Methods

We analysed patients who underwent TAVR between 2016 and 2023 in the KPUM transcatheter aortic valve implantation (TAVI) registry, a prospective multicentre registry in Japan. Five short-term (30-day) MPMs (Society of Thoracic Surgeons Predicted Risk of Mortality [STS-PRoM], French Aortic National CoreValve and Edwards registry [FRANCE-2], Observational Study Of Appropriateness, Efficacy And Effectiveness of AVR-TAVR Procedures For the Treatment Of Severe Symptomatic Aortic Stenosis registry [OBSERVANT], American College of Cardiology-TAVI [ACC-TAVI], and Netherlands Heart Registration [NHR] models) and 3 long-term (1-year) MPMs (Optimized CathEter vAlvular iNtervention-TAVI [OCEAN-TAVI], Osaka University, and TAVR-Risk [TARI] models) were validated. Model performance was assessed using the area under the receiver operating characteristic curve (AU-ROC) for discrimination and calibration plots/slope/intercept for calibration. Intercept recalibration was performed for short-term MPMs.

Results

Among 1756 patients analysed for short-term mortality, the mortality risk was 1.4% (n = 25), while among 1235 patients analysed for long-term mortality, the mortality risk was 14.5% (n = 179), respectively. Among short-term MPMs, NHR (AU-ROC: 0.82) and STS-PRoM (0.78) showed the highest discrimination, though all models overestimated mortality risk, which improved after intercept recalibration. Among long-term MPMs, the OCEAN-TAVI and Osaka University models (AU-ROC: 0.75) showed the highest discrimination, with the OCEAN-TAVI demonstrating the best calibration.

Conclusions

In Japanese TAVR patients, STS-PRoM and NHR models showed superior short-term performance after recalibration, while OCEAN-TAVI demonstrated the best overall long-term performance. Future research should explore machine learning-based models to improve risk prediction accuracy and clinical applicability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementRegistriesAortic Valve StenosisHumansMaleFemaleAged, 80 and overRisk AssessmentAgedJapanProspective StudiesRisk FactorsEast Asian People

Stichwörter der Autor:innen

aortic stenosiscalibrationdiscriminationexternal validationmortalityprediction modeltranscatheter aortic valve replacement (TAVR)

Autor:innen und Institutionen

  • Department of Cardiology, Kyoto Prefectural University of Medicine, Kyoto, 602-8566, Japan.
  • Department of Cardiology, Kyoto Kizugawa Hospital, Kyoto, 610-0101, Japan.
  • Department of Cardiology, Kishiwada Tokushukai Hospital, Osaka, 596-8522, Japan.
  • Department of Cardiology, Kyoto Okamoto Memorial Hospital, Kyoto, 613-0034, Japan.
  • Department of Cardiology, Nishinomiya Watanabe Cardiovascular Center, Hyogo, 662-0911, Japan.
  • Department of Cardiology, Fukui Cardiovascular Center, Fukui, 910-0833, Japan.

ORCID-Profile: Ryo Shibata, Tomotsugu Seki, Tomotaka Fujimoto, Masaki Yashige

Zitieren

APA

Shibata, R., Seki, T., Takeda, Y., Iwaya, T., Kataoka, E., Kitada, T., Takahara, M., Tani, R., Nakamura, S., Fujimoto, T., Yashige, M., Takamatsu, K., Ito, N., Kuwabara, K., Nagata, Y., Yamano, M., Yamano, T., Nakamura, T., Matoba, S., & Zen, K. (2025). External Validation of Mortality Prediction Models in Japanese Transcatheter Aortic Valve Replacement Registry. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1093/ejcts/ezaf227

Vancouver

Shibata R, Seki T, Takeda Y, Iwaya T, Kataoka E, Kitada T, et al. External Validation of Mortality Prediction Models in Japanese Transcatheter Aortic Valve Replacement Registry. European Journal of Cardio-Thoracic Surgery. 2025. doi:10.1093/ejcts/ezaf227

BibTeX
@article{Shibata2025,
  author = {Shibata, Ryo and Seki, Tomotsugu and Takeda, Yuki and Iwaya, Takuma and Kataoka, Eisuke and Kitada, Tatsuya and Takahara, Motoyoshi and Tani, Ryotaro and Nakamura, Shunsuke and Fujimoto, Tomotaka and Yashige, Masaki and Takamatsu, Kazuaki and Ito, Nobuyasu and Kuwabara, Kensuke and Nagata, Yoji and Yamano, Michiyo and Yamano, Tetsuhiro and Nakamura, Takeshi and Matoba, Satoaki and Zen, Kan},
  title = {External Validation of Mortality Prediction Models in Japanese Transcatheter Aortic Valve Replacement Registry},
  journal = {European Journal of Cardio-Thoracic Surgery},
  year = {2025},
  doi = {10.1093/ejcts/ezaf227}
}
Kostenlos starten →