EUVIMEDEUVIMED entdecken
Crossref

Accuracy of artificial intelligence-based simulation for assessing lung vessels and volume using unenhanced computed tomography

Kentaro Fukuta, Yoshihisa Shimada iD, Yuki Nagamatu, Ryosuke Amemiya, Tomokazu Oomori, Hideyuki Furumoto, Yujin Kudo iD, Taro Oba, Masaru Hagiwara, Masatoshi Kakihana, Jinho Park, Tatuso Ohira und 1 weitere

European Journal of Cardio-Thoracic Surgery · 2025

DOI: 10.1093/ejcts/ezae449 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Cardio-Thoracic Surgery, 2025. Verfasst von Kentaro Fukuta und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic Surgery, Tokyo Medical University, Tokyo, Japan. Hauptthemen laut MEDLINE: Artificial Intelligence, Tomography, X-Ray Computed, Imaging, Three-Dimensional, Lung. Die Arbeit wurde bisher 3-mal zitiert (Crossref). Gefördert von: Department of Surgery, Tokyo Medical University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES The advantages of preoperative three-dimensional (3D) image simulations, which require enhanced computed tomography (ECT), for anatomical lung resection are well-documented. However, the necessity for contrast agent presents a significant barrier for some patients. This study thus aims to evaluate the accuracy of an artificial intelligence (AI)-based 3D simulation using unenhanced CT (UECT) data in comparison to ECT data. METHODS The study enrolled 18 lung cancer patients who underwent anatomical lung resections. Utilizing the AI software Version6.7 within the Synapse Vincent system (Fujifilm Corporation, Tokyo, Japan), automatic construction of 3D images of the bronchovascular trees was achieved using both ECT and UECT. We further assessed the accuracy of pulmonary vessel identification on UECT, and compared the calculated lung segment volumes obtained from UECT with those obtained from ECT. RESULTS The comparison of accuracy to operative findings showed that ECT identified 98.9% of artery branches (PAs) and 85.7% of vein branches (PVs), while UECT identified 96.6% of PAs and 82.1% of PVs. Out of 371 PAs and 319 PVs identified on ECT, UECT failed to detect 16 PAs (4.4%) and 32 PVs (10.1%), yielding a correlation coefficient for branch detection of 0.9783 (p < 0.001). There was a significant correlation between ECT and UECT in measuring artery-oriented volumes on both the right-side segments (R = 0.8330) and the left-side segments (R = 0.8082). CONCLUSIONS This 3D image technique using UECT data may be comparable to that obtained with ECT data in terms of achieving lobar and partial segmental branch levels.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial IntelligenceTomography, X-Ray ComputedImaging, Three-DimensionalLungLung NeoplasmsPulmonary ArteryHumansMaleFemaleMiddle AgedAgedPneumonectomyPulmonary VeinsRetrospective Studies

Stichwörter der Autor:innen

Artificial intelligenceLung vesselLung volumeSegmentectomySimulationUnenhanced computed tomography

Autor:innen und Institutionen

  • Department of Thoracic Surgery, Tokyo Medical University, Tokyo, Japan.
  • Department of Radiology, Tokyo Medical University, Tokyo, Japan.

ORCID-Profile: Yoshihisa Shimada, Yujin Kudo

Förderung

  • Department of Surgery, Tokyo Medical University

Zitieren

APA

Fukuta, K., Shimada, Y., Nagamatu, Y., Amemiya, R., Oomori, T., Furumoto, H., Kudo, Y., Oba, T., Hagiwara, M., Kakihana, M., Park, J., Ohira, T., & Ikeda, N. (2025). Accuracy of artificial intelligence-based simulation for assessing lung vessels and volume using unenhanced computed tomography. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1093/ejcts/ezae449

Vancouver

Fukuta K, Shimada Y, Nagamatu Y, Amemiya R, Oomori T, Furumoto H, et al. Accuracy of artificial intelligence-based simulation for assessing lung vessels and volume using unenhanced computed tomography. European Journal of Cardio-Thoracic Surgery. 2025. doi:10.1093/ejcts/ezae449

BibTeX
@article{Fukuta2025,
  author = {Fukuta, Kentaro and Shimada, Yoshihisa and Nagamatu, Yuki and Amemiya, Ryosuke and Oomori, Tomokazu and Furumoto, Hideyuki and Kudo, Yujin and Oba, Taro and Hagiwara, Masaru and Kakihana, Masatoshi and Park, Jinho and Ohira, Tatuso and Ikeda, Norihiko},
  title = {Accuracy of artificial intelligence-based simulation for assessing lung vessels and volume using unenhanced computed tomography},
  journal = {European Journal of Cardio-Thoracic Surgery},
  year = {2025},
  doi = {10.1093/ejcts/ezae449}
}
Kostenlos starten →