EUVIMEDEUVIMED entdecken
Crossref

Implementation of the Versius robotic surgical system for thoracic surgery: first clinical evaluation of feasibility and performance

Sara Fra iD, Usue Caballero-Silva, Alberto Cabañero-Sánchez, Gemma María Muñoz-Molina, Cristina Cavestany García-Matres, Jose Deymar Lozano-Ayala, Luis Lomanto-Navarro, Elena Vílchez-Pernias, Nicolás Moreno-Mata

European Journal of Cardio-Thoracic Surgery · 02.08.2024 · 66 (2)

DOI: 10.1093/ejcts/ezae286 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Cardio-Thoracic Surgery, online erschienen am 23.07.2024. Verfasst von Sara Fra und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic Surgery, Ramon y Cajal University Hospital, Madrid, Spain. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Feasibility Studies, Pneumonectomy. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES The aim of this study is to demonstrate the ability of the Versius surgical system to successfully and safely complete a range of thoracic procedures aligned with Stage 2a (Development) of the Idea, Development, Exploration, Assessment and Long-term follow-up framework for surgical innovation. METHODS This prospective study included the first 30 consecutive patients who underwent robotic surgery with Versius by 2 surgeons without prior robotic experience between 1 April 2023 and 30 December 2023 [25 lung resections (wedge, segmentectomy and lobectomy) and 5 thymectomies]. There were no specific predetermined selection criteria for each case. The primary outcome was safe completion of the procedure without unplanned conversion. Secondary outcomes included intraoperative and postoperative complications, intraoperative device-related outcomes and pathology results. RESULTS Twenty-eight (93.3%) cases were completed without conversion. Both conversions were to thoracoscopy, one due to a ‘console alarm’ and the other due to pulmonary artery bleeding. In lung resections, median console time was 103 (90–129) min. Five (20%) patients experienced postoperative complications, most frequent was persistent air leak (16%). Median length-of-stay was 3 (2–4) days. Neither readmissions nor mortality was observed. In thymectomies, no intraoperative or postoperative complications, readmissions, reinterventions or mortality were observed. Median console time was 77 (75–89) min and median length of stay was 1 (1–1) day. CONCLUSIONS This phase 2a IDEAL-D study confirms lung resections and thymectomies are feasible with the use of Versius system, laying the foundation for larger phase 2b and 3 clinical studies within the IDEAL-D framework.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresFeasibility StudiesPneumonectomyHumansMaleFemaleProspective StudiesMiddle AgedAgedPostoperative ComplicationsAdultThoracic Surgical ProceduresLength of Stay

Stichwörter der Autor:innen

Early resultsIDEAL-D 2aMinimally invasive surgeryRobotic thoracic surgeryVersius

Autor:innen und Institutionen

  • Department of Thoracic Surgery, Ramon y Cajal University Hospital, Madrid, Spain.
  • University of Alcalá, Madrid, Spain.

ORCID-Profile: Sara Fra

Zitieren

APA

Fra, S., Caballero-Silva, U., Cabañero-Sánchez, A., Muñoz-Molina, G. M., Cavestany García-Matres, C., Lozano-Ayala, J. D., Lomanto-Navarro, L., Vílchez-Pernias, E., & Moreno-Mata, N. (2024). Implementation of the Versius robotic surgical system for thoracic surgery: first clinical evaluation of feasibility and performance. European Journal of Cardio-Thoracic Surgery, 66(2). https://doi.org/10.1093/ejcts/ezae286

Vancouver

Fra S, Caballero-Silva U, Cabañero-Sánchez A, Muñoz-Molina GM, Cavestany García-Matres C, Lozano-Ayala JD, et al. Implementation of the Versius robotic surgical system for thoracic surgery: first clinical evaluation of feasibility and performance. European Journal of Cardio-Thoracic Surgery. 2024;66(2). doi:10.1093/ejcts/ezae286

BibTeX
@article{Fra2024,
  author = {Fra, Sara and Caballero-Silva, Usue and Cabañero-Sánchez, Alberto and Muñoz-Molina, Gemma María and Cavestany García-Matres, Cristina and Lozano-Ayala, Jose Deymar and Lomanto-Navarro, Luis and Vílchez-Pernias, Elena and Moreno-Mata, Nicolás},
  title = {Implementation of the Versius robotic surgical system for thoracic surgery: first clinical evaluation of feasibility and performance},
  journal = {European Journal of Cardio-Thoracic Surgery},
  year = {2024},
  volume = {66},
  number = {2},
  doi = {10.1093/ejcts/ezae286}
}
Kostenlos starten →