Fachartikel in der Zeitschrift European Journal of Cardio-Thoracic Surgery, 2024. Verfasst von Yuanjia Zhu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, Stanford University, Stanford, CA, USA. Hauptthemen laut MEDLINE: Mitral Valve Insufficiency, Mitral Valve Prolapse. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
OBJECTIVES Artificial neochordae implantation is commonly used for mitral valve (MV) repair. However, neochordae length estimation can be difficult to perform. The objective was to assess the impact of neochordae length changes on MV haemodynamics and neochordal forces. METHODS Porcine MVs (n = 6) were implanted in an ex vivo left heart simulator. MV prolapse (MVP) was generated by excising at least 2 native primary chordae supporting the P2 segments from each papillary muscle. Two neochordae anchored on each papillary muscle were placed with 1 tied to the native chord length (exact length) and the other tied with variable lengths from 2× to 0.5× of the native length (variable length). Haemodynamics, neochordal forces and echocardiography data were collected. RESULTS Neochord implantation repair successfully eliminated mitral regurgitation with repaired regurgitant fractions of approximately 4% regardless of neochord length (P < 0.01). Leaflet coaptation height also significantly improved to a minimum height of 1.3 cm compared with that of MVP (0.9 ± 0.4 cm, P < 0.05). Peak and average forces on exact length neochordae increased as variable length neochordae lengths increased. Peak and average forces on the variable length neochordae increased with shortened lengths. Overall, chordal forces appeared to vary more drastically in variable length neochordae compared with exact length neochordae. CONCLUSIONS MV regurgitation was eliminated with neochordal repair, regardless of the neochord length. However, chordal forces varied significantly with different neochord lengths, with a preferentially greater impact on the variable length neochord. Further validation studies may be performed before translating to clinical practices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiothoracic Surgery, Stanford University, Stanford, CA, USA.
- Department of Bioengineering, Stanford University, Stanford, CA, USA.
- Department of Mechanical Engineering, Stanford University, Stanford, CA, USA.
ORCID-Profile: Yuanjia Zhu, Y Joseph Woo
Förderung
- NHLBI NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Zhu, Y., Lee, S. H., Venkatesh, A., Wu, C. A., Stark, C. J., Ethiraj, S., Lee, J. J., Park, M. H., Yajima, S., & Woo, Y. J. (2024). Biomechanical engineering analysis of neochordae length’s impact on chordal forces in mitral repair. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1093/ejcts/ezae008
Vancouver
Zhu Y, Lee SH, Venkatesh A, Wu CA, Stark CJ, Ethiraj S, et al. Biomechanical engineering analysis of neochordae length’s impact on chordal forces in mitral repair. European Journal of Cardio-Thoracic Surgery. 2024. doi:10.1093/ejcts/ezae008
BibTeX
@article{Zhu2024,
author = {Zhu, Yuanjia and Lee, Seung Hyun and Venkatesh, Akshay and Wu, Catherine A and Stark, Charles J and Ethiraj, Sidarth and Lee, Justin J and Park, Matthew H and Yajima, Shin and Woo, Y Joseph},
title = {Biomechanical engineering analysis of neochordae length’s impact on chordal forces in mitral repair},
journal = {European Journal of Cardio-Thoracic Surgery},
year = {2024},
doi = {10.1093/ejcts/ezae008}
}
EUVIMED