EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fully automated deep learning MAPSE: retrospective analysis and real-time clinical application

Maria Muan Haga, Nora Lindeman Katla, Vegard Holmstrøm, Espen Holte iD, Stian Stølen, Knut Haakon Stensæth, Andreas Østvik iD, Lasse Løvstakken iD, Håvard Dalen iD, Erik Smistad iD, Bjørnar Grenne iD

European Heart Journal - Imaging Methods and Practice · 01.01.2026 · 4 (1)

DOI: 10.1093/ehjimp/qyag087 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Heart Journal - Imaging Methods and Practice, online erschienen am 19.05.2026. Verfasst von Maria Muan Haga und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Box 8905 Trondheim 7491, Norway. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Norwegian University of Science and Technology, NTNU, Liaison Committee.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Mitral annular plane systolic excursion (MAPSE) is an accessible echocardiographic measure of left ventricular (LV) function. However, manual measurement methods are operator-dependent and time-consuming. We developed a multistep deep learning (DL) method for off-line and real-time fully automated MAPSE estimation, and aimed to assess agreement, reproducibility, time efficiency, and feasibility compared with standard manual measurements. Methods and results The DL-based method was evaluated in two retrospective cohorts (n = 1775) and one prospective cohort (n = 51). Agreement between DL-MAPSE on B-mode images and experts’ manual M-mode measurements was evaluated in all datasets. Evaluation of test–retest reproducibility, time efficiency using real-time analysis during acquisition, and agreement with cardiac magnetic resonance (CMR)-imaging were performed in subsets of the datasets. DL-MAPSE demonstrated good agreement with manual measurements, with bias 2.9 mm (95% CI 2.8–3.0 mm) and Pearson coefficient 0.81 (95% CI 0.79–0.84) in the primary dataset, and a lower bias of 1.0 mm against CMR-MAPSE compared with −2.1 mm using manual M-mode. Both DL and manual measurements showed good test–retest reproducibility (ICC 0.82 and 0.76, respectively). Real-time DL measurements reduced measurement and acquisition time by 51% (mean 1 min 50 s) per examination. The DL method demonstrated excellent feasibility (96%).

Conclusion

This novel DL method for fully automated MAPSE demonstrated excellent feasibility, robust reproducibility, and good agreement with both manual M-mode and CMR-derived measurements. Automated DL-MAPSE could substantially reduce analysis time and enhance reproducibility, increasing its clinical value as a marker of LV systolic function.

Schlagwörter

Stichwörter der Autor:innen

MAPSEartificial intelligencedeep learningechocardiographyreal time

Autor:innen und Institutionen

  • Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Box 8905 Trondheim 7491, Norway.
  • Department of Cardiology and Thoracic Surgery, St.Olavs University Hospital, Trondheim, Norway.
  • Department of Radiology and Nuclear Medicine, St. Olavs University Hospital, Trondheim, Norway.
  • Medical Image Analysis, Health Research, SINTEF Digital, Trondheim, Norway.
  • Department of Medicine, Levanger Hospital, Nord-Trøndelag Hospital Trust, Levanger, Norway.

ORCID-Profile: Espen Holte, Andreas Østvik, Lasse Løvstakken, Håvard Dalen, Erik Smistad, Bjørnar Grenne

Förderung

  • Norwegian University of Science and Technology
  • NTNU
  • Liaison Committee
  • Central Norway Regional Health Authority
  • Simon Fougner Hartmann Family Fund
  • St. Olavs University hospital

Zitieren

APA

Haga, M. M., Katla, N. L., Holmstrøm, V., Holte, E., Stølen, S., Stensæth, K. H., Østvik, A., Løvstakken, L., Dalen, H., Smistad, E., & Grenne, B. (2026). Fully automated deep learning MAPSE: retrospective analysis and real-time clinical application. European Heart Journal - Imaging Methods and Practice, 4(1). https://doi.org/10.1093/ehjimp/qyag087

Vancouver

Haga MM, Katla NL, Holmstrøm V, Holte E, Stølen S, Stensæth KH, et al. Fully automated deep learning MAPSE: retrospective analysis and real-time clinical application. European Heart Journal - Imaging Methods and Practice. 2026;4(1). doi:10.1093/ehjimp/qyag087

BibTeX
@article{Haga2026,
  author = {Haga, Maria Muan and Katla, Nora Lindeman and Holmstrøm, Vegard and Holte, Espen and Stølen, Stian and Stensæth, Knut Haakon and Østvik, Andreas and Løvstakken, Lasse and Dalen, Håvard and Smistad, Erik and Grenne, Bjørnar},
  title = {Fully automated deep learning MAPSE: retrospective analysis and real-time clinical application},
  journal = {European Heart Journal - Imaging Methods and Practice},
  year = {2026},
  volume = {4},
  number = {1},
  doi = {10.1093/ehjimp/qyag087}
}
Kostenlos starten →