Comparing transthoracic echocardiography, 2D and 4D flow cardiovascular magnetic resonance for quantitative valve assessment after percutaneous pulmonary valve implantation

Marguerite E Faure iD, Joao G Carvalho, Annemien E van den Bosch iD, Jeroen M Wilschut, Tim Ten Cate, Anthonie L Duijnhouwer iD, Jolien W Roos-Hesselink iD, Ricardo P J Budde, Alexander Hirsch iD

European Heart Journal - Imaging Methods and Practice · 01.01.2026 · 4 (1)

DOI: 10.1093/ehjimp/qyag054 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Heart Journal - Imaging Methods and Practice, online erschienen am 29.03.2026. Verfasst von Marguerite E Faure und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, Erasmus MC, Room Rg-419, PO Box 2040, 3000 CA, Rotterdam, The Netherlands. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: GE Healthcare, Erasmus MC, Siemens.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

To compare transthoracic echocardiography (TTE), 2D and 4D flow cardiovascular magnetic resonance (CMR) for the evaluation of valve function and flow measurements after percutaneous pulmonary valve implantation (PPVI). Methods and results In this multicentre exploratory observational study, 29 patients who underwent PPVI were planned for TTE and CMR with 2D and 4D flow measurements after PPVI. Peak velocity was measured with all techniques. Net and regurgitating flow measurements were measured with CMR distal to the transcatheter pulmonary valve (TPV). Median peak velocity of the TPV with TTE was 2.5 (2.0–3.1) m/s, with 2D flow CMR 2.3 (2.0–3.2) m/s, and with 4D flow 2.3 (2.0–3.0) m/s. There was a good correlation for the peak velocity of the TPV between TTE and 2D flow CMR (r = 0.68, P < 0.001) and a moderate correlation for peak velocity between TTE and 4D flow CMR (r = 0.56, P = 0.003), and between 2D flow and 4D flow CMR (r = 0.56, P = 0.006). For peak velocity measurements, no proportional bias was observed between the three imaging techniques. For the CMR flow measurements, a strong correlation was observed between 2D and 4D flow CMR, for both net flow (r = 0.87, P < 0.001) and regurgitation fraction (r = 0.96, P < 0.001) of the TPV. Net flow through the left pulmonary artery correlated strongly between 2D and 4D flow CMR (r = 0.85, P < 0.001), and there was a good correlation for the right pulmonary artery (r = 0.65, P < 0.01). For net flow measurements of the TPV, we found an underestimation of flow measurements at higher flow rates with 4D flow CMR, compared to 2D flow CMR.

Conclusion

TTE, 2D flow CMR, and 4D flow CMR are all feasible and reliable imaging techniques after PPVI, concordant in predominantly mild-to-moderate stenosis. These findings strengthen the use of 2D and 4D flow CMR as a tool for post-PPVI assessment, despite stent-induced artefacts, although reliability in more advanced valve dysfunction remains uncertain.

Schlagwörter

Stichwörter der Autor:innen

4D flowcardiovascular magnetic resonancepercutaneous pulmonary valve implantationphase contrasttransthoracic echocardiography

Autor:innen und Institutionen

  • Department of Radiology and Nuclear Medicine, Erasmus MC, Room Rg-419, PO Box 2040, 3000 CA, Rotterdam, The Netherlands.
  • Department of Radiology, AZ Monica, Antwerp, Belgium.
  • Department of Radiology, Centro Hospitalar Universitário de Santo António, Porto, Portugal.
  • Department of Cardiology, Cardiovascular Institute, Thorax Center, Erasmus MC, Room Rg-419, PO Box 2040, 3000 CA, Rotterdam, The Netherlands.
  • Department of Cardiology, Radboud University Medical Center, Nijmegen, The Netherlands.

ORCID-Profile: Marguerite E Faure, Annemien E van den Bosch, Anthonie L Duijnhouwer, Jolien W Roos-Hesselink, Alexander Hirsch

Förderung

  • GE Healthcare
  • Erasmus MC
  • Siemens
  • Heartflow
  • Bracco

Zitieren

APA

Faure, M. E., Carvalho, J. G., van den Bosch, A. E., Wilschut, J. M., Ten Cate, T., Duijnhouwer, A. L., Roos-Hesselink, J. W., Budde, R. P. J., & Hirsch, A. (2026). Comparing transthoracic echocardiography, 2D and 4D flow cardiovascular magnetic resonance for quantitative valve assessment after percutaneous pulmonary valve implantation. European Heart Journal - Imaging Methods and Practice, 4(1). https://doi.org/10.1093/ehjimp/qyag054

Vancouver

Faure ME, Carvalho JG, van den Bosch AE, Wilschut JM, Ten Cate T, Duijnhouwer AL, et al. Comparing transthoracic echocardiography, 2D and 4D flow cardiovascular magnetic resonance for quantitative valve assessment after percutaneous pulmonary valve implantation. European Heart Journal - Imaging Methods and Practice. 2026;4(1). doi:10.1093/ehjimp/qyag054

BibTeX
@article{Faure2026,
  author = {Faure, Marguerite E and Carvalho, Joao G and van den Bosch, Annemien E and Wilschut, Jeroen M and Ten Cate, Tim and Duijnhouwer, Anthonie L and Roos-Hesselink, Jolien W and Budde, Ricardo P J and Hirsch, Alexander},
  title = {Comparing transthoracic echocardiography, 2D and 4D flow cardiovascular magnetic resonance for quantitative valve assessment after percutaneous pulmonary valve implantation},
  journal = {European Heart Journal - Imaging Methods and Practice},
  year = {2026},
  volume = {4},
  number = {1},
  doi = {10.1093/ehjimp/qyag054}
}
Kostenlos starten →