Evaluation of left intraventricular flow dynamics using the novel non-contrast HyperDoppler technique
European Heart Journal - Imaging Methods and Practice · 01.01.2026 · 4 (1)
DOI: 10.1093/ehjimp/qyag050 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Heart Journal - Imaging Methods and Practice, online erschienen am 19.03.2026. Verfasst von Riccardo Beccari und 30 weiteren Autor:innen. Beteiligte Einrichtung: Cardiac Unit, Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Aims
Recently, HyperDoppler, a colour Doppler-based ultrasound technique, has been introduced for left ventricular (LV) flow dynamics evaluation in clinical settings, but quantitative information derived from its use is limited. We aimed at establishing reference values and reproducibility of key HyperDoppler LV flow dynamics measures: vortex area, length, depth, intensity, and global kinetic energy dissipation (gKED) in normal subjects. We also explored the influence of physiological and echocardiographic variables on HyperDoppler measures. Methods and results This multicentre, international study involved 13 echocardiographic laboratories and an independent echo corelab. A total of 467 normal subjects were enrolled and categorized by gender and age (20–39, 40–59, and 60–79 years): of these, 317 subjects were analysed at the corelab and 419 on-site using different colour Doppler cineloops. Corelab analysis yielded a median value (25th–75th percentile) of 25.0% (21.1–28.0%) for vortex area, 57.4% (53.3–62.6%) for vortex length, 34.3% (30.7–38.1%) for vortex depth, −31.9% (−28.0% to −35.8%) for vortex intensity, and 0.55 (0.44–0.70) for gKED. Minor age- and gender-related variations were noted in vortex length, depth, and gKED. Excellent reproducibility was shown for each HyperDoppler measure. Physiological behaviour of left intraventricular flow dynamics was adequately captured by the HyperDoppler quantitative measures.
Conclusion
Reference values for left intraventricular flow dynamics were established using the HyperDoppler technique, which is reproducible and enables the assessment of intracardiac flow dynamics in clinical practice.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiac Unit, Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy.
- Cardiac Unit, Buon Consiglio Fatebenefratelli Hospital, Napoli, Italy.
- Centro Cardiologico Monzino IRCCS, Milano, Italy.
- Sports Medicine Center, University of Firenze, Firenze, Italy.
- Division of Cardiology, Department of Medical Biotechnologies, University of Siena, Siena, Italy.
- Department of Clinical and Experimental Medicine, University of Messina, Messina, Italy.
ORCID-Profile: Antonella Cecchetto, Mauro Pepi, Giancarlo Trimarchi, Jagat Narula, Donato Mele
Zitieren
APA
Beccari, R., Cecchetto, A., Smarrazzo, V., Miano, V., Pepi, M., Fazzari, F., Stefani, L., Corsi, M., Cameli, M., Focardi, M., Zito, C., Trimarchi, G., Kasprzak, J., Filipiak-Strzecka, D., Cogliati, C., Torzillo, D., Aquila, I., Ventura, E., Sabatino, J., …, & Mele, D. (2026). Evaluation of left intraventricular flow dynamics using the novel non-contrast HyperDoppler technique. European Heart Journal - Imaging Methods and Practice, 4(1). https://doi.org/10.1093/ehjimp/qyag050
Vancouver
Beccari R, Cecchetto A, Smarrazzo V, Miano V, Pepi M, Fazzari F, et al. Evaluation of left intraventricular flow dynamics using the novel non-contrast HyperDoppler technique. European Heart Journal - Imaging Methods and Practice. 2026;4(1). doi:10.1093/ehjimp/qyag050
BibTeX
@article{Beccari2026,
author = {Beccari, Riccardo and Cecchetto, Antonella and Smarrazzo, Vittorio and Miano, Vittoria and Pepi, Mauro and Fazzari, Fabio and Stefani, Laura and Corsi, Marco and Cameli, Matteo and Focardi, Marta and Zito, Concetta and Trimarchi, Giancarlo and Kasprzak, Jaroslaw and Filipiak-Strzecka, Dominika and Cogliati, Chiara and Torzillo, Daniela and Aquila, Iolanda and Ventura, Ettore and Sabatino, Jolanda and De Sarro, Rosalba and Pepe, Marco and Incarnato, Pierluigi and Bezante, Giampaolo and Costa, Paolo and Prieto, Omar and Maglione, Marco and Rascón-Sabido, Raphael and Gregori, Dario and Narula, Jagat and Pedrizzetti, Gianni and Mele, Donato},
title = {Evaluation of left intraventricular flow dynamics using the novel non-contrast HyperDoppler technique},
journal = {European Heart Journal - Imaging Methods and Practice},
year = {2026},
volume = {4},
number = {1},
doi = {10.1093/ehjimp/qyag050}
}