EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Four-dimensional analysis of aortic root motion in normal population using retrospective multiphase computed tomography

Xun Yuan iD, Xiaoxin Kan, Jianpeng Li, Yang Yan, Saeed Mirsadraee iD, Tarun Mittal, Andrew Shah, Debbie Saunders, Xiao Yun Xu, Christoph A Nienaber iD

European Heart Journal - Imaging Methods and Practice · 16.01.2024 · 2 (1)

DOI: 10.1093/ehjimp/qyae007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Heart Journal - Imaging Methods and Practice, online erschienen am 05.02.2024. Verfasst von Xun Yuan und 9 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology and Aortic Centre, Royal Brompton & Harefield Hospitals, Guy's and St Thomas' NHS Foundation Trust, Sydney Street, London SW3 6NP, UK. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Aortic root motion is suspected to contribute to proximal aortic dissection. While motion of the aorta in four dimensions can be traced with real-time imaging, displacement and rotation in quantitative terms remain unknown. The hypothesis was to show feasibility of quantification of three-dimensional aortic root motion from dynamic CT imaging. Methods and results Dynamic CT images of 40 patients for coronary assessment were acquired using a dynamic protocol. Scans were ECG-triggered and segmented in 10 time-stepped phases (0–90%) per cardiac cycle. With identification of the sinotubular junction (STJ), a patient-specific co-ordinate system was created with the z-axis (out-of-plane) parallel to longitudinal direction. The left and right coronary ostia were traced at each time-step to quantify downward motion in reference to the STJ plane, motion within the STJ plane (in-plane), and the degree of rotation. Enrolled individuals had an age of 65 ± 12, and 14 were male (35%). The out-of-plane motion was recorded with the largest displacement of 10.26 ± 2.20 and 8.67 ± 1.69 mm referenced by left and right coronary ostia, respectively. The mean downward movement of aortic root was 9.13 ± 1.86 mm. The largest in-plane motion was recorded at 9.17 ± 2.33 mm and 6.51 ± 1.75 mm referenced by left and right coronary ostia, respectively. The largest STJ in-plane motion was 7.37 ± 1.96 mm, and rotation of the aortic root was 11.8 ± 4.60°.

Conclusion

In vivo spatial and temporal displacement of the aortic root can be identified and quantified from multiphase ECG-gated contrast-enhanced CT images. Knowledge of normal 4D motion of the aortic root may help understand its biomechanical impact in patients with aortopathy and pre- and post-surgical or transcatheter aortic valve replacement.

Schlagwörter

Stichwörter der Autor:innen

aortic aneurysmaortic dissectionaortic root motiondynamic imagingmultiphase CTroot displacement

Autor:innen und Institutionen

  • Cardiology and Aortic Centre, Royal Brompton & Harefield Hospitals, Guy's and St Thomas' NHS Foundation Trust, Sydney Street, London SW3 6NP, UK.
  • National Heart and Lung Institute, School of Medicine, Imperial College London, Exhibition Road, London SW7 2BX, UK.
  • Center for Vascular Surgery and Wound Care, Jinshan Hospital, Fudan University, Shanghai, China.
  • Department of Chemical Engineering, Imperial College London, London, UK.
  • Department of Cardiovascular Surgery, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
  • Department of Radiology, Royal Brompton & Harefield Hospitals, Guy's and St Thomas' NHS Foundation Trust, London, UK.

ORCID-Profile: Xun Yuan, Saeed Mirsadraee, Christoph A Nienaber

Zitieren

APA

Yuan, X., Kan, X., Li, J., Yan, Y., Mirsadraee, S., Mittal, T., Shah, A., Saunders, D., Xu, X. Y., & Nienaber, C. A. (2024). Four-dimensional analysis of aortic root motion in normal population using retrospective multiphase computed tomography. European Heart Journal - Imaging Methods and Practice, 2(1). https://doi.org/10.1093/ehjimp/qyae007

Vancouver

Yuan X, Kan X, Li J, Yan Y, Mirsadraee S, Mittal T, et al. Four-dimensional analysis of aortic root motion in normal population using retrospective multiphase computed tomography. European Heart Journal - Imaging Methods and Practice. 2024;2(1). doi:10.1093/ehjimp/qyae007

BibTeX
@article{Yuan2024,
  author = {Yuan, Xun and Kan, Xiaoxin and Li, Jianpeng and Yan, Yang and Mirsadraee, Saeed and Mittal, Tarun and Shah, Andrew and Saunders, Debbie and Xu, Xiao Yun and Nienaber, Christoph A},
  title = {Four-dimensional analysis of aortic root motion in normal population using retrospective multiphase computed tomography},
  journal = {European Heart Journal - Imaging Methods and Practice},
  year = {2024},
  volume = {2},
  number = {1},
  doi = {10.1093/ehjimp/qyae007}
}
Kostenlos starten →