EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY-NC 4.0

Percutaneous management of atrial flow regulator thrombosis in failing Fontan: a case report

Maria Teresa Quarta iD, Enrico Piccinelli iD, Micol Rebonato iD, Mara Pilati iD, Gianfranco Butera iD

European Heart Journal - Case Reports · 04.11.2026 · 10 (11)

DOI: 10.1093/ehjcr/ytag604 ↗

Kurz gefasst

Fallbericht in der Zeitschrift European Heart Journal - Case Reports, online erschienen am 17.08.2026. Verfasst von Maria Teresa Quarta und 4 weiteren Autor:innen. Beteiligte Einrichtung: Bambino Gesù Children's Hospital, IRCCS, Piazza Sant'Onofrio 4, Rome 00165, Italy. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Concomitant thrombosis of the Fontan conduit and atrial flow regulator highlights the marked prothrombotic milieu characteristic of failing Fontan circulation. Case summary We report a case of a 12-year-old with double inlet left ventricle, malposition of the great arteries, and aortic arch hypoplasia who underwent single ventricle palliation with Fontan completion at the age of 7 years. Over the following years, he developed protein-losing enteropathy associated with ascitic and pleural effusions; therefore, fenestration of the Fontan conduit was performed using an atrial flow regulator. Despite anticoagulation therapy with rivaroxaban, thrombosis of the atrial flow regulator occurred 1 month after implantation. The device was retrieved after multiple attempts using a grasping forceps, but conduit thrombosis occurred. Fenestration stenting was performed, and thromboaspiration was successfully performed, protecting the systemic circulation with a balloon inflated across the fenestration. At the 6-month follow-up, the patient remained haemodynamically stable, with a patent fenestration and no evidence of visceral effusions.

Discussion

This case underscores the challenges of managing device-related thrombosis in patients with failing Fontan circulation and demonstrates the potential role of a fully percutaneous treatment strategy.

Schlagwörter

Stichwörter der Autor:innen

Atrial flow regulatorCase reportFailing FontanPercutaneous managementThrombosis

Autor:innen und Institutionen

  • Bambino Gesù Children's Hospital, IRCCS, Piazza Sant'Onofrio 4, Rome 00165, Italy.
  • Department of Pediatrics, University 'G. D'Annunzio' of Chieti-Pescara, Via Dei Vestini 5, Chieti 66100, Italy.

ORCID-Profile: Maria Teresa Quarta, Enrico Piccinelli, Micol Rebonato, Mara Pilati, Gianfranco Butera

Zitieren

APA

Quarta, M. T., Piccinelli, E., Rebonato, M., Pilati, M., & Butera, G. (2026). Percutaneous management of atrial flow regulator thrombosis in failing Fontan: a case report. European Heart Journal - Case Reports, 10(11). https://doi.org/10.1093/ehjcr/ytag604

Vancouver

Quarta MT, Piccinelli E, Rebonato M, Pilati M, Butera G. Percutaneous management of atrial flow regulator thrombosis in failing Fontan: a case report. European Heart Journal - Case Reports. 2026;10(11). doi:10.1093/ehjcr/ytag604

BibTeX
@article{Quarta2026,
  author = {Quarta, Maria Teresa and Piccinelli, Enrico and Rebonato, Micol and Pilati, Mara and Butera, Gianfranco},
  title = {Percutaneous management of atrial flow regulator thrombosis in failing Fontan: a case report},
  journal = {European Heart Journal - Case Reports},
  year = {2026},
  volume = {10},
  number = {11},
  doi = {10.1093/ehjcr/ytag604}
}
Kostenlos starten →