EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Cerebral air embolism after implantation of a leadless pacemaker via the right internal jugular vein: a case report

Pierre Ollitrault iD, Mayane Al Khoury iD, Laure Champ-Rigot iD, Jonaz Font iD, Arnaud Pellissier iD

European Heart Journal - Case Reports · 01.06.2026 · 10 (6)

DOI: 10.1093/ehjcr/ytag446 ↗

Kurz gefasst

Fallbericht in der Zeitschrift European Heart Journal - Case Reports, online erschienen am 09.06.2026. Verfasst von Pierre Ollitrault und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology; Caen University Hospital, Normandie Univ, UniCaen, Avenue de la Côte de Nacre, Caen F-14000, France. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Leadless pacemaker (LP) implantation is associated with fewer device-related complications than conventional transvenous pacing systems. While traditionally performed via the femoral vein, the right internal jugular (RIJ) approach has recently emerged as an alternative strategy, potentially improving catheter control. However, safety data for this approach remain limited. Case summary A 77-year-old man with precapillary pulmonary hypertension, diabetes mellitus, and recurrent traumatic syncope underwent LP implantation via the RIJ vein following documentation of infra-Hissian conduction delay (HV interval 80 ms). The procedure was uneventful, with satisfactory electrical parameters. Immediately after repositioning the patient in a 30° head-up position, he developed acute neurological deterioration (Glasgow Coma Scale 6/15). Transthoracic echocardiography (TTE) excluded pericardial effusion but revealed air bubbles in the right ventricle. Cerebral computed tomography demonstrated multiple air bubbles within the right intracerebral venous system, consistent with retrograde cerebral venous air embolism. Emergency management included Trendelenburg positioning, 100% oxygen administration, and hyperbaric oxygen therapy. Neurological status improved, although a persistent left-sided motor deficit remained. At 15-month follow-up, no further syncope occurred, and the LP functioned normally, but residual left limbs hypokinesia persisted.

Discussion

This case illustrates a rare but severe complication of RIJ LP implantation. Large-bore sheath use, low venous pressure in the jugular system, relative dehydration, severe pulmonary vascular disease, and early head-up positioning likely contributed to retrograde cerebral venous air migration. Strict preventive measures—including meticulous system flushing, adequate hydration, maintenance of slight Trendelenburg positioning, and post-procedural echocardiographic screening—may help mitigate this risk.

Schlagwörter

Stichwörter der Autor:innen

Case reportCerebral air embolismInternal jugular veinLeadless pacemakerSafety

Autor:innen und Institutionen

  • Department of Cardiology; Caen University Hospital, Normandie Univ, UniCaen, Avenue de la Côte de Nacre, Caen F-14000, France.
  • Normandy Heart Rhythm Association, Avenue de la Côte de Nacre, Caen F-14000, France.

ORCID-Profile: Pierre Ollitrault, Mayane Al Khoury, Laure Champ-Rigot, Jonaz Font, Arnaud Pellissier

Zitieren

APA

Ollitrault, P., Al Khoury, M., Champ-Rigot, L., Font, J., & Pellissier, A. (2026). Cerebral air embolism after implantation of a leadless pacemaker via the right internal jugular vein: a case report. European Heart Journal - Case Reports, 10(6). https://doi.org/10.1093/ehjcr/ytag446

Vancouver

Ollitrault P, Al Khoury M, Champ-Rigot L, Font J, Pellissier A. Cerebral air embolism after implantation of a leadless pacemaker via the right internal jugular vein: a case report. European Heart Journal - Case Reports. 2026;10(6). doi:10.1093/ehjcr/ytag446

BibTeX
@article{Ollitrault2026,
  author = {Ollitrault, Pierre and Al Khoury, Mayane and Champ-Rigot, Laure and Font, Jonaz and Pellissier, Arnaud},
  title = {Cerebral air embolism after implantation of a leadless pacemaker via the right internal jugular vein: a case report},
  journal = {European Heart Journal - Case Reports},
  year = {2026},
  volume = {10},
  number = {6},
  doi = {10.1093/ehjcr/ytag446}
}
Kostenlos starten →