Catheter ablation of a mechanically traumatized atrioventricular accessory pathway by targeting its ventricular insertion determined by pace mapping: a case report
European Heart Journal - Case Reports · 02.05.2025 · 9 (5)
DOI: 10.1093/ehjcr/ytaf253 ↗Kurz gefasst
Fallbericht in der Zeitschrift European Heart Journal - Case Reports, online erschienen am 19.05.2025. Verfasst von Ghassan Moubarak und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrophysiology and Pacing, Centre Médico-Chirurgical Ambroise Paré, 48Ter Boulevard Victor Hugo, Neuilly-sur-Seine 92200, France. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Catheter ablation is a highly effective treatment of atrioventricular accessory pathways (APs). Catheter-induced mechanical trauma of the AP is not infrequent during electrophysiology study and can lead to procedure discontinuation. We present an alternative method to successfully ablate a persistently traumatized AP. Case summary A 15-year-old patient was referred for ablation of a symptomatic parahisian AP. Unfortunately, the AP was mechanically traumatized during catheter placement, and conduction did not resume after a 45-min waiting period. We proceeded to determine the ventricular insertion of the AP. Pace mapping was performed at the ventricular aspect of the tricuspid annulus with bipolar pacing from the ablation catheter. Using electroanatomic mapping, a correlation map between the maximally pre-excited QRS morphology (recorded at the beginning of the electrophysiological study) and the pace-mapped QRS was displayed. The highest correlation was 94%. The area delimited by the 3 best pace-map matching points was considered the target area, and radiofrequency applications were delivered. No recurrence of pre-excitation or palpitations were observed during 6 months of follow-up.
Discussion
Determining the distal ventricular insertion of a mechanically traumatized AP is feasible, by comparing a maximally pre-excited QRS with the paced-mapped QRS. Electroanatomic correlation mapping may help delineate a limited target area before ablation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrophysiology and Pacing, Centre Médico-Chirurgical Ambroise Paré, 48Ter Boulevard Victor Hugo, Neuilly-sur-Seine 92200, France.
ORCID-Profile: Ghassan Moubarak
Zitieren
APA
Moubarak, G., Zhao, A., Semichon, M., Grimard, C., & Sharifzadehgan, A. (2025). Catheter ablation of a mechanically traumatized atrioventricular accessory pathway by targeting its ventricular insertion determined by pace mapping: a case report. European Heart Journal - Case Reports, 9(5). https://doi.org/10.1093/ehjcr/ytaf253
Vancouver
Moubarak G, Zhao A, Semichon M, Grimard C, Sharifzadehgan A. Catheter ablation of a mechanically traumatized atrioventricular accessory pathway by targeting its ventricular insertion determined by pace mapping: a case report. European Heart Journal - Case Reports. 2025;9(5). doi:10.1093/ehjcr/ytaf253
BibTeX
@article{Moubarak2025,
author = {Moubarak, Ghassan and Zhao, Alexandre and Semichon, Marc and Grimard, Caroline and Sharifzadehgan, Ardalan},
title = {Catheter ablation of a mechanically traumatized atrioventricular accessory pathway by targeting its ventricular insertion determined by pace mapping: a case report},
journal = {European Heart Journal - Case Reports},
year = {2025},
volume = {9},
number = {5},
doi = {10.1093/ehjcr/ytaf253}
}
EUVIMED